For the Intermec 9730

Page 115

6. Input devices

6. Input devices - the following input devices can be connected to the MicroBar - pen barcode readers - laser / CCD barcode readers in wand / laser emulation - undecoded magstripe readers - RS-232 input devices (electronic scales, barcode readers, magstripe readers, . . .) 1 pen

2

4 true RS-232 C input device undecoded laser gun

3

1

5

RS-232 TTL input device undecoded laser gun

CCD scanner in laser emulation

CCD scanner in laser emulation

1 pen

1 pen undecoded magstripe reader

2 pens with dual-pen adaptor

4

6

MicroBar 9730 - Installation Manual

115

Page 116

6. Input devices laser scanners / CCD scanners in laser emulation laser scanners / CCD scanners in laser emulation - laser scanners or CCD scanners in laser emulation connected to ports 4 and 5 of the MicroBar activation port 4 - IMPORTANT ! - Do not read the activation codes in this section if the scanner you are using is already reading correctly as this could deactivate the MicroBar for your scanner !!! - if this happens, use another barcode reader (a pen for example) to read each of the port activation codes in this section until you reactivate the MicroBar for your scanner Intermec Sabre 1550 X05 / other scanners (*)

\4B\5D\00\04\60 for Sabre 1550 X05 with standard interface (default scanner for port 4) and other scanners not specified in this section 9-position D-sub cable connector Intermec Sabre 1550 X01

\4B\5D\02\04\60

- for Sabre 1550 X01 with Intermec interface - 9-position D-sub cable connector Symbol LS 3000 LR only

\4B\5D\01\04\60

116

MicroBar 9730 - Installation Manual

Page 117

6. Input devices laser scanners / CCD scanners in laser emulation port 5 - IMPORTANT ! - Do not read the activation codes in this section if the scanner you are using is already reading correctly as this could deactivate the MicroBar for your scanner !!! - if this happens, use another barcode reader (a pen for example) to read each of the port activation codes in this section until you reactivate the MicroBar for your scanner Intermec Sabre 1550 X01 (*)

\4B\5D\02\05\60 for Sabre 1550 X01 with Intermec interface (default scanner for port 5) 10-pin modular plug Intermec Sabre 1550 X05 / other scanners

\4B\5D\00\05\60

- for Sabre 1550 X05 with standard interface and other scanners not specified in this section - 10-pin modular plug Symbol LS 3000 LR only

\4B\5D\01\05\60

MicroBar 9730 - Installation Manual

117

Page 118

6. Input devices laser scanners / CCD scanners in laser emulation laser trigger management RS-232 trigger - some laser scanners can be activated by a user-defined RS-232 character sent by the host system (software activation) not active (*)

\49\42\3E\00\60 compose activation character:

\49\42\60

- enter an ASCII character and scan End Selection (Appendix A)

CTS trigger - some laser scanners can be activated according to the level of the CTS signal received (voltage level activation) not active (*)

\49\43\00\60 low level active

\49\43\01\60 high level active

\49\43\02\60

118

MicroBar 9730 - Installation Manual

Page 119

6. Input devices laser scanners / CCD scanners in laser emulation laser timeout before deactivation - MicroBar can control the timeout period before deactivation (laser scanners normally remain active until the trigger is released or they reach the end of their timeout) - valid for all laser trigger configurations unlimited (*)

\49\44\00\60 the laser scanner remains active all the time LASER SAFETY: CAUTION - LASER LIGHT CAN DAMAGE YOUR EYES. DO NOT STARE INTO BEAM. 1 sec

\49\44\01\60

2 sec

\49\44\02\60

3 sec

\49\44\03\60

8 sec

\49\44\08\60

MicroBar 9730 - Installation Manual

119

Page 120

6. Input devices laser scanners / CCD scanners in laser emulation

"code not read" message - informs the host system if the barcode data has not been successfully decoded when the trigger is released or the timeout period is reached (particularly useful to indicate unread codes when scanners are used in autostand mode for example) not active (*)

\49\45\3E\00\60 compose non-read ASCII character:

\49\45\60

- enter an ASCII character and scan End Selection (Appendix A) - character used to indicate a non-read compose repetition number: [range: 1-20]

\49\46\60 enter a number string and scan End Selection (Appendix C) number of non-read characters sent to the host system (max 20)

120

MicroBar 9730 - Installation Manual

Page 121

6. Input devices laser scanners / CCD scanners in laser emulation consecutive same read data validation - ensures correct transmission of data for difficult reading conditions and varying levels of barcode quality (poorly printed labels, variable lengths and no check digit, "fragile" symbologies) - data is only transmitted after repeated reads give the same result - fixed length / minimum length settings for the symbologies in your application also increase the reliability of the barcode data transmitted (see "barcode length" for your symbologies) - increasing the security level reduces the reading speed !!! single read before transmission (*)

\45\4B\01\60 compose number of consecutive same reads before transmission: [range: 1-10]

\45\4B\60

- enter a number string and scan End Selection (Appendix C)

MicroBar 9730 - Installation Manual

121

Page 122

6. Input devices magstripe readers magstripe readers track selection - MicroBar can read 1 track or 2 tracks from a possible total of 1, 2, or 3 tracks read all tracks (*)

\48\40\00\60 track 1 or 3

\48\40\01\60 track 2

\48\40\02\60 tracks 1 and 2

\48\40\03\60 tracks 2 and 3

\48\40\04\60 transmission sequence track 1 / track 3 then track 2 (*)

\48\41\00\60 track 2 then track 1 / track 3

\48\41\01\60

122

MicroBar 9730 - Installation Manual

Page 123

6. Input devices magstripe readers track separator character - default = # character (ASCII 35) # (ASCII 35) (*)

\48\42\03\60 compose separator character:

\48\42\60

- enter an ASCII character and scan End Selection (Appendix A)

start/end sentinels not transmitted (*)

\48\44\00\60 transmitted

\48\44\01\60

LRC check digit checked but not transmitted (*)

\48\43\00\60 checked and transmitted

\48\43\01\60

MicroBar 9730 - Installation Manual

123

Page 124

6. Input devices scales / weighing machines scales / weighing machines scale solicitation - sends a solicitation message to an input device on port 4 or port 5 (typically scales or a weighing machine) when a matching input scenario is encountered (the scales will then send data for transmission to the host system) - if the data editing and scale solicitation functions have an identical input scenario, data editing has priority (scale solicitation will not occur !!!) - use adaptor cable 0-234032-02 to connect an RS-232 device to port 4 deactivate

\4C\45\08\00\60 deactivates scale solicitation in the MicroBar define: this option only available with EasySet 1. define the input scenario you want to use to trigger scale solicitation : - select any combination of input port, input type (symbology, RS-232...), message length, input mask 2. define the the solicit message you want to send to the scale and specify the port the scale is connected to - make sure that the input scenario you define actually corresponds to incoming data conditions !!! - correct input port (no value = 'any port') - correct input type (no value = 'any input type') - correct message length (no value = 'any length') - correct input characters')

124 mask

(no value

=