The text of a manual · part 5 of 31
9560 Transaction Manager User's Manual, pages 41 to 50
Pages 41 to 50 of 309
The original document is the PDF (1.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 9560
Page 41
Preparing to Install the 9560
2
Connecting Directly to a Computer You can connect a computer directly to the 9560 modem connector. If the connector on the computer is a plug (not a socket), then use a socket/socket adapter cable, such as Intermec Part No. 035009S. The 9560 modem connector is wired as a Data Terminal Equipment (DTE) device.
Connecting to a Computer
Modem Connector
Computer
9560-06U
You need a null modem cable, such as Intermec Part No. 043069, or any other null modem cable that meets these standards: •
4-wire null modem cable
•
10-foot suggested length
•
25-pin D-subminiature connector that is compatible with the computer
•
25-pin, D-subminiature plug connector at one end
Connecting to a Computer and Terminal If your system includes a computer and a terminal, connect the computer to the 9560 modem connector first. Use a null modem cable as described in the previous section, “Connecting Directly to a Computer.” Next connect the CRT terminal or other ASCII device to the 9560 terminal connector with a modem cable. The terminal connector is wired as a Data Communications Equipment (DCE) device.
2-13
Page 42
9560 Transaction Manager User’s Manual
Connecting to a Computer and Terminal Terminal Connector
CRT Terminal
Modem Connector
Computer
9560-10U
You need a modem cable, such as Intermec cable Part No. 043237S. You can also use any other modem cable that meets these standards: •
4-wire modem cable
•
8-foot suggested length
•
25-pin D connector
•
Plug connector at one end that is compatible with the terminal
•
25-pin “D” subminiature socket connector at one end
Connecting to a Port Concentrator or System Unit You can connect one or more 9560s to a port concentrator or other system unit. You use direct wiring to connect the 9560 directly to the port concentrator. You use multi-drop line wiring to connect several 9560s to the same line and port. If your system also includes a CRT, connect the CRT cable to the terminal connector.
2-14
Page 43
Preparing to Install the 9560
2
Connecting the 9560 to a Port Concentrator Modem Connector
Modem Connector
Port Concentrator
9560-11U
Connecting the 9560 to a 9154 Line Controller Modem Connector
9154 Line Controller
9560-12U
Port Concentrator Options Concentrator
Protocol
Interface
Cable
9161B Option 01
Polling Mode D
RS-232 or RS-422
RS-232 cable, Intermec Part No. 041789S RS-422 cable, supplied by customer
9161B Option 02
Polling Mode D or Multi-Drop
RS-232, RS-422, or 4-wire RS-485 multi-drop
RS-232 cable, Intermec Part No. 041789S RS-422 cable supplied by customer RS-485 cable, Part No. 047661
9165A
Polling Mode D
RS-232 or RS-422
Supplied by customer
9154 Line Controller
Multi-Drop
4-wire RS-485
RS-485 cable, Intermec Part No. 047661
2-15
Page 44
9560 Transaction Manager User’s Manual
Direct Wiring Direct wiring to a port concentrator requires a cable with the following: •
One connector that is compatible with the port concentrator
•
25-pin, D-subminiature plug connector
The modem connector is wired as a Data Terminal Equipment (DTE) device. For more information, see “Null Modem Cable Diagram and Modem Connector Pin Assignments” earlier in this section.
Multi-Drop Line Wiring You can connect one or more 9560s to a concentrator using RS-485 multi-drop line wiring. The multi-drop layout consists of a main line up to 2000 feet long, as shown in in the following diagram.
Multi-Drop Wiring to a Port Concentrator
Port Concentrator
2000 Ft Max 30 Ft Max Device
Device
Device
9560-08U
You can connect up to 32 readers, with each a maximum of 20 feet from the main line. If you use Intermec cable Part No. 047653, you can space the readers up to 30 feet. Intermec has tested and approved this layout. Any other multidrop system layout may not work properly. For multi-drop wiring, you need a cable that meets these standards:
2-16
•
4-wire cable with two individually shielded wire pairs
•
One connector that is compatible with the computer
•
25-pin, D-subminiature plug connector
•
At least 24-gauge wire
•
Nominal impedance ≤ 150 ohms
•
Nominal capacitance ≤ 20 pF/ft
•
Attenuation ≤ 6 dbv in 2000 feet.
Page 45
Preparing to Install the 9560
2
Intermec recommends using a cable capable of passing the VW-1 vertical flame test. The following table lists Belden cables that meet these requirements.
Belden Cable Meeting Multi-Drop Requirements Belden Part
VW-1 Test
Gauge
Nominal Impedance
Nominal Capacitance
6 dbv
9729
No
24
100
12.5
2100
8102
No
24
100
12.5
2100
8162
No
24
100
12.5
2100
82729
UL Listed (60°C)
24
100
12.5
2100
89729
UL Listed (200°C)
24
100
12.5
2100
Note: Belden cable #89729 has the additional feature of being UL listed for use in an air plenum without being in conduit - NEC Article 725, UL classified, Class 2 Circuits).
You can make open, unshielded, connections between cable sections with heat shrink or other applied protection. Keep the unshielded section shorter than 2.0 inches (5.08 cm). You do not need a shielded box for connections. Connect sections to the concentrator or the 9560 at pin 1 of the selected channel, as shown in the following diagram.
Cable/Connector Diagram for Multi-Drop Wiring
9-Pin D Sub Male Port Concentrator 1 4 6 8 9
GND 1 RXDB 13 RXDA 16 TXDB 19 TXDA 14
GND 1 RXDB 13 RXDA 16 TXDB 19 TXDA 14
Devices
GND 1 RXDB 13 RXDA 16 TXDB 19 TXDA 14
Shield TXDB TXDA RXDB RXDA
9560-09U
2-17
Page 46
9560 Transaction Manager User’s Manual
Meeting Power Supply Requirements The 9560 contains an internal power supply that automatically adjusts to any input from 100 to 240 VAC and from 50 to 60 Hz. A standard IEC connector, located on the chassis and directly below the connector board, accepts various power cords used throughout the world. To fit properly, a power cord must have a right-angle connector with a maximum overall height of 1.77 inches (45 mm). The 9560 is designed to be powered on continuously: there is no power switch. to remove power from the unit, simply unplug the power cord. If the reader is configured to resume IRL and the power is disconnected while a program is running, the program resumes when you restore power.
2-18
Page 47
code39 helconital nugget
3 Installing the 9560
A F
B
K
G
C
L
H
D
M
I
P U
Q V
R W
E N
J
S
O
X
T Y
C ap s $ 7
/ , Z
4
8
1
5
9
2
6
0
3
B ks p
S pa ce
In
. E n te r te rm
F 1 F 2 F 3 F 4 F 5
F 6 F 7 F 8 F 9
9 F10 5 6 0 ec
Page 48
nugget code39 helconital
Page 49
Installing the 9560
3
This chapter contains the installation procedures for the 9560. To properly and safely install the 9560, you must read this entire chapter and understand the installation process.
Overview of Installing the 9560 Before installing the 9560, make sure that you received all the necessary parts. Your shipment should include these components: •
9560 unit and housing
•
AC power cord
•
Security plate with three screws
•
Mounting plate with eight screws.
The following two drawings show the main 9560 components.
9560 Parts and Their Locations Mounting Plate
Display A F
Housing
Keypad
K P
(Alpha Characters optional)
U
B G L Q V
C H M R W
D I N S X
E J O T
Ca ps $ /
Power Connector
7
1
Z
-
Inte
8
4
, Y
5 2
Bk
0
9
A rme Co mp c an y
3
F1
.
sp
Litt on
6
F2
Sp ace En ter
F3 F4
Chassis
F5
F6 F7 F8 F9 F1 0
95 60
Slot Scanner Security Plate
Connector PCB 9560-45U
3-3
Page 50
9560 Transaction Manager User’s Manual
Connector PCB Parts and Their Locations
Battery
Sense Jumper Block
Relays Connector PCB
Audio Connector
Terminal Blocks
Wand/Slot Scanner Connector
Terminal Exit IRL Laser Connector Switch Scanner Modem Connector Connector 9560-44U
General Installation Steps Your system requirements determine some of the installation steps. In general, follow these steps to install the 9560: 1. Read and follow all warnings and cautions. 2. Turn off the power to the installation area. 3. Route the cables through the mounting plate. 4. Connect the cables for any external devices. 5. Connect the AC power cable. Do not turn on the power. 6. Attach the mounting plate to the housing. 7. Attach the unit to the wall or other surface. The next sections explain Steps 3 through 7.
WARNING
Warning The 9560 uses potentially hazardous AC power. For your safety, you must understand and follow all safety procedures in this manual and any and all local building codes. Intermec does not assume liability for personal injury, death, or equipment damage that occurs as a result of your failure to comply with the installation procedures contained in this manual. Avertissement Comme la 9560 utilise le courant AC, qui est potentiellement hazardeux, il est impératif que vous preniez en considération la sécurité de toutes personnes installant ou opérant cet équipement. Il faut lire et suivre les avertissements cidessous. Intermec n'assume aucune responsabilité en cas de blessures personnelles, mort ou endommagement d'équipement dûs à l'inobservation de l'opérateur des procédures d'installation indiquées dans ce manuel.
3-4