The text of a manual · part 4 of 31
9560 Transaction Manager User's Manual, pages 31 to 40
Pages 31 to 40 of 309
The original document is the PDF (1.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 9560
Page 31
Preparing to Install the 9560
2
This chapter contains the background information you need before you install the 9560. If you are familiar with the 9560, you may skip this chapter.
Getting Ready to Install the 9560 Once you are familiar with the 9560, you are ready to plan your system and how to include the 9560. The following topics provide the background information you need: •
Determining a mounting location
•
Selecting external devices
•
Connecting to a data collection system
•
Meeting power supply requirements
If you are already familiar with these topics, skip ahead to Chapter 3, “Installing the 9560.”
2-3
Page 32
9560 Transaction Manager User’s Manual
Determining a Mounting Location You can mount the 9560 on a horizontal surface, such as a desktop, or on a vertical surface, such as a wall. Make sure that the mounting location provides the following: •
Easy access to the internal card reader
•
Easy access to all front panel keys
•
An unobstructed view of the display
•
Clearance for cables and power supply
9560 Mounted on a Wall
A F K P U
B G L Q V
C H M R W
D I N S X
E J O T
Ca ps $ / ,
Y Z
7
Inte
8
4
5
1
2
-
0
Bk
9
A
3
En ter rme ton mp c an y
F1 F2
Sp ac e
Lit
Co
6
.
sp
F3 F4 F5
F6 F7 F8 F9 F1 0
95 60
Mount the 9560 right side up as shown.
9560-37U
Note: The 9560 is moisture- and dust-resistant only if it is mounted right side up on a wall or other vertical surface.
2-4
Page 33
Preparing to Install the 9560
2
Choosing Secured or Unsecured Wiring Before mounting the 9560, you must choose which type of wiring your system requires. Secured wiring protects the cables from exposure and requires you to install the security plate on the 9560. Unsecured wiring routes the cables into the room with no extra protection. Note: To comply with IEC 950, you must install the 9560 near an easily accessible socket outlet.
Selecting External Devices You can use many types of external devices with the 9560.
Choosing Input Devices You use input devices, such as wands and laser scanners, to provide information to the 9560. Input devices can supplement or replace the internal scanner or card reader included with the 9560. This Input Device
Connects To
1200 series digital wands
Wand (modular) connector
1350 series badge scanners
Wand (modular) connector
1500 and 1600 series laser scanners (with 9-pin D-subminiature connector)
Laser scanner connector
1700 keyboard
Wand (modular) connector
9191 digital satellite wand station
Wand (modular) connector
Any asynchronous CRT terminal
Terminal plug
RS-232 magnetic stripe reader
Terminal plug
Any asynchronous host computer
Modem socket
Note: If you order the 9560 with the internal slot scanner or magnetic card reader, you may not need an additional input device.
Attaching Wands and Scanners You can connect a combination of wands and scanners to the 9560 if you are certain that you will use only one device at a time. The 9560 uses the same video line for the internal slot scanner and the external scanners (9191 satellite wand stations, laser scanners). If you try to scan from any two of these devices at the same time, the 9560 does not accept any input at all.
2-5
Page 34
9560 Transaction Manager User’s Manual
For example, if your system has a 9191 satellite wand station and an internal slot scanner, you can only scan from one or the other at one time. The 9560 cannot process information from both scanners at the same time. The internal magnetic card reader does not use the video line and does not interfere with wands or scanners. You can swipe a magnetic card and scan a label with a wand at the same time.
Attaching Devices to the Terminal Plug Use the terminal plug to attach a remote terminal, external magnetic card reader, or other device to the 9560. If you order the 9560 with the internal magnetic card reader, you cannot attach an external device to the terminal plug. The internal magnetic card reader uses the terminal plug.
Installing the 9560 Without Input Devices You can install the 9560 without a 1700 keyboard or any other external input device. If you do, you must start the IRL program before permanently mounting the unit, or you must start the IRL program from the host. For more information, see “Creating and Running IRL Programs” in Chapter 9.
Unattended Scanning You can configure the 9560 to accept input from an unattended laser scanner. For example, you can mount a laser scanner beside a conveyor line where boxes with bar code labels pass in front of the scanner. You can set the scanner to automatically scan when it senses a label. This is called remote triggering. You either physically set the 9560 for remote triggering, or you can send software commands to the 9560. To physically enable remote triggering 1. Position jumper J17 to short pins 1 and 2.
J17
9560-30U
Or, provide an external device that senses when a bar code is waiting to be read. When triggered, the external device should short pin 11 on either the modem or terminal port to signal ground (pin 7). Do not use pin 11 on the unused port.
2-6
Page 35
Preparing to Install the 9560
2
2. Set the 9560 trigger mode to edge and define a scanner timeout. To set these parameters, see Chapter 6, “Configuring the 9560,” and Chapter 7, “Configuration Commands.” To enable remote triggering with software commands 1. Set the scanner to Auto Trigger mode. See “Enter Auto Trigger Mode” in Chapter 8. 2. Set the 9560 trigger mode to edge and define a scanner timeout. To set these parameters, see Chapter 6, “Configuring the 9560,” and Chapter 7, “Configuration Commands.” Note: Remote triggering requires an environment with an electrically clean signal. Noise or static will disrupt the scanner.
Using the Sense Inputs The 9560 includes three sense inputs and three output relays. You use the inputs to monitor events, such as the opening and closing of doors or gates. For example, you may want the reader to beep if the door open. Each sense input monitors its line for an input signal within the following range: •
1 msec minimum duration
•
5V to 24V (AC or DC)
•
10mA to 60mA
You select the voltage range of the input signal by setting a jumper on the appropriate jumper block. Each sense input is isolated to protect the 9560 from any damaging currents that may inadvertently enter through the input line. Voltage Range
Jumper Setting
5 to 14 V
Pins 1 and 2
14 to 24 V
Pins 2 and 3
When a sense input detects a signal, the circuitry is put in a “set” state. The circuitry remains set until the software reads the status of the sense inputs. When the 9560 executes an IRL F command, it places the status of the inputs into the #0 register and resets the circuitry. For more information, see Chapter 9, “Interactive Reader Language.”
2-7
Page 36
9560 Transaction Manager User’s Manual
The status is stored as follows: •
The #0 register contains a 3-digit binary string.
•
A 1 indicates a signal has been detected; a 0 indicates no signal.
•
The digits correspond to the inputs as shown in the following diagram:
01 1
Register #0
Third input J3
First input J1 Second input J2 9560-40U
For example, if the #0 register contains 011, it would indicate a signal at the first and second inputs, but none at the third input. The following diagram shows a typical connection to a sense input. In this example, a normally open door sense switch is wired in series with the sense input and a secondary power circuit. When the door switch is closed, the sense input detects the 24V output from the power circuit.
Sample Sense Input Application
Optical Isolator
330
Input Range Selection 1 Jumper Block Terminal Block
1200 2
3
1 2 3 4 5
For 5-14V input, jumper pins 1 and 2. For 14-24V input, jumper pins 2 and 3.
9560
Normally Open Door Sense Switch Secondary circuit of no more than 24 VDC or VAC and no more than 60 mA.
2-8
External
9560-03U
Page 37
Preparing to Install the 9560
2
Using the Output Relays The 9560 includes three sense inputs and three single-pole, double-throw output relays. You use these relays to actuate external devices, such as door or turnstile locks. Each relay is rated as follows: •
24V (AC or DC) maximum
•
1A maximum.
You control the relays with the IRL F command command. If you execute a reset or remove power to the 9560, the relays turn off. The relays remain off until the 9560 receives an F command. For more information on the F command, see Chapter 9, “Interactive Reader Language.” The following diagram shows the output relays in a typical application.
Sample Output Relay Application
Terminal Block
1 2 3 4 5
Relay
9560
Electric Door Opener Secondary circuit of no more than 24 VDC or VAC and no more than 1A.
External 9560-05U
Attaching Audio Output Devices The 9560 contains a 0.138 inch (3.5 mm) audio jack for connecting an external amplifier and speaker or headphones. When you plug a connector into the audio jack, the internal speaker is disconnected.
2-9
Page 38
9560 Transaction Manager User’s Manual
Connecting to a Data Collection System You can connect the 9560 into a data collection system in one of three ways: •
Connect to a computer only
•
Connect to a computer and terminal
•
Connect to a port concentrator or system unit with or without a terminal
Before connecting the data collection system, be sure your system meets the interface requirements listed next.
Cable Interface Requirements You can connect the 9560 to an RS-232, RS-422, or 4-wire RS-485 multi-drop interface. The type of cabling depends upon the distance between the 9560 and the other components of the system, as shown in the following table. Maximum Distance
Preferred Interface
50 feet
RS-232
2000 feet
RS-485 multi-drop (use only with a 9161A Option 2 multidrop concentrator or 9154 Line Controller)
4000 feet
RS-422
RS-232 is designed for short distances and is generally not used for long data lines. It can be used successfully over longer distances if there is a “clean” electrical environment in the building. Because RS-232 connects the two signal grounds of the units together, any ground noise is coupled directly to the units. RS-232 cables longer than 50 feet are susceptible to noise and may cause data transmission problems. To avoid problems with longer RS-232 cables, you can install modems at each end of the cable. Modems isolate the equipment grounds from the cable and reduce noise. Follow the modem manufacturer’s instructions for terminating the cable, and be sure that the modem has transformer coupling or optical isolation. RS-422 uses balanced transmission to provide noise immunity. The transmission is received with a differential receiver, and the receiver signal ground is not common with the cable. Note: If you use RS-422 or RS-485 wiring, you must configure the 9560 for the chosen interface. The default is RS-232. For information about host protocols and interface considerations, see Chapter 5, “Data Communications and Operating Options.”
2-10
Page 39
Preparing to Install the 9560
2
The following cable diagrams and connector pin assignments apply to the three 9560 data collection system choices: •
Computer
•
Computer and terminal
•
Port concentrator or system control unit with or without a terminal
Null Modem Cable Diagram and Modem Connector Pin Assignments To Reader
To Computer
13
25
1
14 9560-07U
The 25-pin null modem cable works with an RS-232 interface only. You will need to build a custom cable if you are using RS-422 or RS-485. Use the pin assignments from the following table to build a custom cable for the modem connector.
Modem Connector Pin Assignments Direction From Reader
Interface
Pin No.
Signal
RS-232
1
Chassis Ground (optional)
2
Transmitted Data
Outgoing
3
Received Data
Incoming
4
Request to Send
Outgoing
5
Clear to Send
Incoming
7
Signal Ground (required)
20
Data Terminal Ready
1
Chassis Ground (optional)
13
Received Data B
Incoming
14
Transmitted Data A
Outgoing
16
Received Data A
Incoming
19
Transmitted Data B
Outgoing
11
Remote Triggering (when enabled)
RS-422 and 4-wire RS-485 all
Outgoing
2-11
Page 40
9560 Transaction Manager User’s Manual
Modem Cable Diagram and Terminal Connector Pin Assignments To Reader
To Computer
13
25
1
14 9560-07U
The 25-pin modem cable works with an RS-232 interface only. You will need to build a custom cable if you are using RS-422 or RS-485. Use the pin assignments from the following table to build a custom cable for the terminal connector.
Terminal Connector Pin Assignments Pin No.
Signal
RS-232
1
Chassis Ground (optional)
2
Transmitted Data
Incoming
3
Received Data
Outgoing
4
Request to Send
Incoming
5
Clear to Send
Outgoing
7
Signal Ground (required)
1
Chassis Ground (optional)
13
Received Data B
Outgoing
14
Transmitted Data A
Incoming
16
Received Data A
Outgoing
19
Transmitted Data B
Incoming
11
Remote Triggering (when enabled)
RS-422 and 4-wire RS-485 all
2-12
Direction From Reader
Interface