Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 3 of 31

9560 Transaction Manager User's Manual, pages 21 to 30

Pages 21 to 30 of 309

The original document is the PDF (1.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Intermec 9560

Page 21

code39 helconital nugget

1 Getting Started

A F

B

K

G

C

L

H

D

M

I

P U

Q V

R W

E N

J

S

O

X

T Y

C ap s $ 7

/ , Z

4

8

1

5

9

2

6

0

3

B ks p

S pa ce

In

. E n te r te rm

F 1 F 2 F 3 F 4 F 5

F 6 F 7 F 8 F 9

9 F10 5 6 0 ec

Page 22

nugget code39 helconital

Page 23

nugget code39 helconital Getting Started

1

This chapter provides a roadmap to installing and using the 9560 Transaction Manager and provides an overview of the 9560.

Roadmap For Help With

Start Here

Getting to know the 9560

Read this chapter to learn basic options and components of the 9560.

Installing the 9560

Read Chapter 2 for background information on external devices, wiring requirements, and data collection systems. Read Chapter 3 for step-by-step instructions to install the 9560.

Using the 9560

Read Chapter 4 for instructions on starting the 9560 and using the 9560, wands, scanners, and card readers.

Learning about data communications

Read Chapter 5 to learn basic theories, operating parameters, and protocols for data communications.

Configuring the 9560 for your system

Read Chapter 6 for step-by-step configuring instructions. Read Chapter 7 for a reference of all configuration options. If needed, read Chapter 5 for data communications basics.

Customizing the 9560 for your application needs

Use Chapter 6 to configure the 9560, then refer to the command reference in Chapters 7 and 8 for specific modifications.

IRL Programming

Read Chapter 9 for an overview of IRL (Interactive Reader Language), IRL commands specific to the 9560, and sample IRL programs.

Troubleshooting

Look in Chapter 10 for help with common problems.

System specifications and ASCII bar codes

Use the Appendixes to find system specifications, ASCII bar codes, and a summary of 9560 commands.

Definitions

Look up unfamiliar terms in the Glossary.

1-3

Page 24

code39 helconital

9560 Transaction Manager User’s Manual nugget

The 9560 Transaction Manager The Intermec 9560 Transaction Manager is a stationary online data collection reader. It collects data from digital input devices, such as a bar code scanner, and transmits the data to a host device, such as a PC. The following drawing shows the 9560 in a typical data collection system.

Host Computer

Port Concentrator

Supervisory CRT

Door Sensor (connects to Sense Input)

7

Inte

8

4

5

1

2

-

0

Bk

9

A rme

Litto n Co

6 mpa c ny

3

F1

.

sp

F2

Sp ac e En ter

F3 F4 F5

F6 F7 F8 F9 F1 0

95 60

9560

Laser Scanner

Door Lock (connects to Output Relay)

Bar Code Label

9191 Satellite Wand Station 9560-01U

Note: The 9560 is built to withstand constant use in industrial environments, but improper use can damage it. To avoid problems, please read this manual carefully.

1-4

Page 25

nugget code39 helconital Getting Started

1

9560 Component Options The 9560 offers two display options, three keyboard options, and three reader options. Both displays are LCD displays with an LED backlight. All keyboards have programmable function keys. You have these basic options for the 9560: •

2-line by 40-character display

•

1-line by 20-character oversized display

•

Full alphanumeric keypad with tactile feedback

•

Numeric/function keypad with tactile feedback

•

Numeric/function keypad with large function keys

•

Bar code slot scanner

•

Magnetic card reader

•

No internal reader

You can monitor and control other devices through the three input/output relays in the 9560. The sense inputs monitor various events, such as opening and closing doors. The output relays allow the 9560 to control external devices, such as door locks. The following drawing shows the keyboards and displays for the 9560. Your version may have any combination of the available options.

2x40

Code 128 STANDARD

1x20

Code 128 STANDARD

Inte A

Lit rme ton

Co mp c an y

95 60

Alphanumeric Numeric

Numeric II 9560-46U

1-5

Page 26

9560 Transaction Manager User’s Manual nugget code39 helconital

Optional Input Devices The 9560 accepts input from several sources. The basic configuration includes either an internal magnetic card reader or an internal slot scanner. The slot scanner is available in visible or infraredlight models. You can connect any of the following input devices to the 9560: •

1700 Digital Keyboard

•

9191 Digital Satellite Wand Station

•

1260/1270 Series Digital Wands

•

1350 Series Badge Scanners

•

1500/1600 Series Laser Scanners

•

RS-232 magnetic stripe reader

•

Any asynchronous CRT terminal

•

Any asynchronous host computer

Data Formats and Programming The 9560 can format the data it collects to meet your system’s protocol and communication requirements. You specify the format by scanning bar code command labels, downloading command sequences from the host, or selecting options from menus in the reader’s Prompting Configuration mode. You can develop custom programs for the 9560 with the Interactive Reader Language (IRL). IRL provides the flexibility of a high-level language and does not require a development system. See Chapter 9, “Interactive Reader Language,” for more information on IRL. You can store programs in the 9560’s memory (256K of RAM) or in the host’s memory to be downloaded to the reader. If the 9560 loses power, a NiCad battery retains the memory for up to 10 days.

Memory The 9560 provides 256K of RAM for storing IRL programs and data. The data may be validation files or collected input, especially if the host cannot receive data. The maximum memory available is limited as follows:

1-6

Type

Maximum Size

System overhead

12K

IRL programs

52K

Data (with IRL programs)

182K

Data (no IRL programs)

240K

Page 27

nugget code39 helconital Getting Started

1

Bar Code Symbologies The 9560 can automatically discriminate between several bar code symbologies. You can set the reader to decode any combination of the valid symbologies. You can save reader memory by enabling only the symbologies required for your tasks. The 9560 can decode these bar code symbologies: •

Code 39

•

HIBC

•

Interleaved 2 of 5 (I 2 of 5; variable length and even, fixed length)

•

Code 2 of 5

•

Codabar (Standard, American Blood Commission, and Concatenated)

•

UPC (including supplemental codes for periodicals)

•

EAN

•

Code 11

•

Code 93

•

Code 128

Communications The 9560 supports RS-232, RS-422, and 4-wire RS-485 multi-drop communications standards. Current loop can be supported with an external adapter. Contact your local Intermec service supplier for suggested manufacturers and ordering instructions.

Status Beeps The 9560 sounds high or low beeps to indicate status conditions. A single beep means a valid read, a high pitched beep means immediate transmission to the host, and a low pitched beep means no transmission. For more information on beep sequences, see “Starting the 9560” in Chapter 4. The 9560 standard speaker may not be loud enough in an extremely noisy environment. You can connect a set of headphones or an external amplifier and speaker to the audio connector. For more information, see “Attaching Audio Output Devices” in Chapter 2. You can attach an external speaker or light to a relay to supplement the standard speaker. For more information, see “Selecting External Devices” in Chapter 2.

1-7

Page 28

This page is a scan with no text; see it in the PDF.

Page 29

code39 helconital nugget

2 Preparing to Install the 9560

A F

B

K

G

C

L

H

D

M

I

P U

Q V

R W

E N

J

S

O

X

T Y

C ap s $ 7

/ , Z

4

8

1

5

9

2

6

0

3

B ks p

S pa ce

In

. E n te r te rm

F 1 F 2 F 3 F 4 F 5

F 6 F 7 F 8 F 9

9 F10 5 6 0 ec

Page 30

nugget code39 helconital