Page 51
Installing the 9560
WARNING
3
Warning When you install the 9560, you must strictly follow the procedures in this manual and any and all local building codes. Failure to comply may result in a hazardous situation. Avertissement Il faut réaliser l'installation de la 9560 en suivant strictement les procédures décrites dans ce manuel ainsi que tout code de construction local, le cas échéant, faute de quoi vous risquez de provoquer une situation hasardeuse.
WARNING
Warning Never open the 9560 by separating the chassis from the housing. Injury or death can result from the high voltage levels inside. Avertissement La 9560 présente un niveau de voltage hasardeux lorsqu'elle est mise sous tension. Il ne faut jamais l'ouvrir en séparant le cadre du logement, faute de quoi vous risquez blessures ou mort.
Routing Cables and Power Supply You can route the cables and power supply in two ways: •
Secured wiring - through the wall into the back of the 9560 with no exposed wires
•
Unsecured wiring - through the hole in the bottom of the 9560 with the wires exposed to the room
3-5
Page 52
9560 Transaction Manager User’s Manual
Routing With Secured Wiring Use the following drawing as a guide for routing secured wiring in the 9560.
Mounting Plate
Mounting Surface
A F K P U
B G L Q V
C H M R W
D I N S X
E J O T
Cap s $ /
7
1 -
Inte
8
4
, Z
Y
5 2 0
Bk
9
A
Lit rme ton
6
Co mpa c
Sealed Hole ny
3
F1
.
sp
F2
Sp ac e En ter
F3 F4 F5
F6 F7 F8 F9 F1 0
95 60
View rotated 180°
Security Plate 9560-42U
To route the 9560 with secured wiring 1. Attach the security plate to the bottom of the housing with the three screws. 2. Route all wires through a sealed, watertight hole in the mounting surface. 3. Route the wires through the sealing foam in the mounting plate. 4. Connect the wires to the appropriate connector on the 9560. See “Connecting External Devices” later in this chapter. 5. After you connect all other devices, connect the power supply cable.
3-6
Page 53
Installing the 9560
3
Routing With Unsecured Wiring Use the following drawing as a guide to routing unsecured wiring in the 9560. Mounting Plate
Mounting Surface
A F K P U
B G L Q V
C H M R W
D I N S X
E J O T
Ca ps $ /
7
1
Z
-
Inte
8
4
, Y
5 2 0
Bks
9
A rme om pa c ny
3
F1
.
p
Litto nC
6
F2
Spa ce Ent er
F3 F4 F5
F6 F7 F8 F9 F1 0
95 60
View rotated 180°
9560-43U
To route the 9560 with unsecured wiring 1. Route the wires through the slot in the bottom of the housing. 2. Route the wires through the sealing foam in the mounting plate. 3. Connect the wires to the appropriate connector on the 9560. See the next section, “Connecting External Devices.” 4. After you connect all other devices, connect the power supply cable.
3-7
Page 54
9560 Transaction Manager User’s Manual
Connecting External Devices External devices, such as scanners, laser wands, CRTs, and sense input devices, connect to the 9560 PCB connector board. The following drawing shows the connector locations. Battery
Sense Jumper Block
Relays Connector PCB
Terminal Blocks
Audio Connector
Terminal Exit IRL Laser Connector Switch Scanner Modem Connector Connector
Wand/Slot Scanner Connector
9560-44U
You connect the sense input devices and output relay devices to the terminal blocks and jumpers as shown.
Sense Input and Output Component Locations
J5 J7
1
3-8
2
3
4
5
J3
J2
J1
J6
1
2
3
4
5
1
2
3
4
5
9560-04U
Page 55
Installing the 9560
3
Connecting Input Devices Connect the input device to the connector listed in the following table. Model and Description
Connect To
1260 and 1270 Series digital wands
Wand (modular) connector
1350 Series badge scanners
Wand (modular) connector
1500 and 1600 Series laser scanners (with 9-pin D-sub connector)
Laser scanner connector
1700 Keyboard
Wand (modular) connector
9191 Digital Satellite Wand Station
Wand (modular) connector
Any asynchronous CRT terminal
Terminal plug
RS-232 magnetic stripe reader
Terminal plug
Any asynchronous host computer
Modem socket
Connecting to Sense Inputs You use sense inputs to monitor conditions, such as a door opening or closing. You connect the Sense input lines to terminals 4 and 5 of a terminal block. For more information, see “Selecting External Devices” in Chapter 2. Caution Power to the sense inputs must be from a Class 2 circuit of 5V to 24V, 10mA to 60mA. Never connect main power lines directly to the inputs. Failure to comply could result in equipment damage. Conseil Le courant utilisé par les lecteurs sensoriels doit provenir d'un circuit Classe 2 de 5V - 24V, 10mA - 60mA. Ne connectez jamais les lignes de courant principales directement aux lecteurs, faute de quoi vous risquez d'endommager l'équipement.
3-9
Page 56
9560 Transaction Manager User’s Manual
To connect to sense inputs 1. Determine the required terminal and jumper blocks, and then set the jumpers for the sense inputs. a. Use the following terminal and jumper blocks for each sense input: Sense Input
Terminal Block
Jumper Block
1 2 3
J1 J2 J3
J5 J6 J7 b. Set the jumpers for the voltage levels for the sense inputs as follows: For this voltage
Set jumper pins
5V to 14V 14V to 24V jumper pins 1 and 2 jumper pins 2 and 3.
2. Connect the external sense input device to posts 4 and 5 of the appropriate terminal block. The switch mechanism on each device should normally be open. Use the following diagram as a guide.
Sample Sense Input Application
Optical Isolator
330
Input Range Selection 1 Jumper Block Terminal Block
1200 2
3
1 2 3 4 5
For 5-14V input, jumper pins 1 and 2. For 14-24V input, jumper pins 2 and 3.
9560
Normally Open Door Sense Switch Secondary circuit of no more than 24 VDC or VAC and no more than 60 mA.
3-10
External
9560-03U
Page 57
Installing the 9560
3
Connecting to Output Relays You use the output relays to control external devices, such as an electronic door lock. You connect output devices to terminals 1, 2, and 3 of a terminal block. For more information, see “Selecting External Devices” in Chapter 2. Caution Power to the external portion of the output relay circuit must be from a Class 2 circuit providing a maximum of 24V, 1A. Never connect main power lines directly to the terminal block. Failure to comply could result in equipment damage. Conseil Le courant utilisé par la partie extérieure du circuit de relais en sortie doit provenir d'un circuit Classe 2 fournissant un maximum de 24V, 1A. Ne connectez jamais les lignes de courant principales directement au bloc du terminal, faute de quoi vous risquez d'endommager l'équipement.
To connect output relays 1. Use the following terminal blocks for each output relay: Output Relay
Terminal Block
1 2 3
J1 J2 J3
2. Connect the external devices to the appropriate terminal block. a. If the device requires a normally closed contact, connect the wires to posts 1 and 2 on the terminal block. b. If the device requires a normally open contact, connect the wires to posts 2 and 3 on terminal block.
3-11
Page 58
9560 Transaction Manager User’s Manual
Sample Output Relay Application
Terminal Block
1 2 3 4 5
Relay
9560
Electric Door Opener Secondary circuit of no more than 24 VDC or VAC and no more than 1A.
External 9560-05U
Connecting Audio Devices You can connect an external amplifier and speaker or a set of headphones to the 9560. Connect the cables from the audio device to jumper J12 inside the 9560.
Connecting to a Data Collection Host System Data collection systems vary greatly. For guidelines and system requirements, see “Connecting to a Data Collection System” in Chapter 2.
3-12
Page 59
Installing the 9560
3
Attaching the Mounting Plate After connecting all cables to the 9560, attach the mounting plate to the housing. Use the following drawing as a guide.
Attaching the Mounting Plate to 9560 Housing
Mounting Plate
Mounting Surface
Mounting Screws (3 places)
A F K P U
B G L Q V
C H M R W
D I N S X
E J O T
Cap s $ /
7
1 -
Inte
8
4
, Z
Y
5 2 0
Bk
9
A
Lit rme ton
6
Co mpa c ny
3
F1
.
sp
F2
Sp ac e En ter
F3 F4 F5
F6 F7 F8 F9 F1 0
95 60
Mounting Plate Screw (8 places. Torque value: 3-4 in/lbs.) 9560-39U
To attach the mounting plate to the housing 1. Make sure all cabling passes through the sealing foam unbunched and evenly spaced, as shown below. This routing protects the seal integrity for secured and unsecured wiring. 2. Fasten the mounting plate over the rear of the 9560 with the eight 6-32 flathead machine screws (Phillips drive). Torque the screws to 3-4 in-lbs with a torque driver.
3-13
Page 60
9560 Transaction Manager User’s Manual
Routing Cables through the Sealing Foam
Sealing Foam
9560-32U
WARNING
Warning If you need to remove the 9560 mounting plate, first disconnect power to the unit. Failure to comply could result in injury or death. Avertissement Si vous devez enlever la plaque de montage de la 9560, il faut d'abord coupe le courant de l'équipement, faute de quoi vous risquez blessures ou mort.
3-14