Page 161

Configuration Commands - IRL PAK (Program Acknowledge)

7

IRL PAK (Program Acknowledge) Purpose:

Character sent by the reader to the host to acknowledge receiving an IRL program.

Default:

RS (record separator)

Syntax:

ZAdata

Acceptable values for data are: Any ASCII character NUL = disable Scan:

To disable PAK, scan this label: Disable PAK

*$+ZA%U$-* *$+ZA%U$ - *

Or:

To set PAK to an ASCII character: 1. Scan this label: Set PAK

*+/$+ZA* *+/$+ZA*

2. Scan a label for data from the full ASCII chart in Appendix B, “Full ASCII Chart.” 3. Scan this label: Exit Configuration, Save Settings

*$-* *$ - *

7-29

Page 162

Configuration Commands - IRL PSS (Program Statement Separator)

IRL PSS (Program Statement Separator) Purpose:

Indicates the separation character for IRL program statements. Do not define PSS as the same character used for EOM.

Default:

CR (carriage return)

Syntax:

XEdata

Acceptable values for data are: Any ASCII character NUL = disable Scan:

To disable PSS, scan this label: Disable PSS

*$+XE%U$-* *$+XE%U$ - *

Or:

To set PSS to an ASCII character: 1. Scan this label: Set PSS

*+/$+XE* *+/$+XE*

2. Scan a label for data from the full ASCII chart in Appendix B, “Full ASCII Chart.” 3. Scan this label: Exit Configuration, Save Settings

*$-* *$ - *

7-30

Page 163

Configuration Commands - IRL RUN

7

IRL RUN Purpose:

Indicates the end of an IRL program block when downloading from the host to the reader.

Default:

DC2

Syntax:

XCdata

Acceptable values for data are: Any ASCII character NUL = disable Scan:

To disable RUN, scan this label: Disable RUN

*$+XC%U$-* *$+XC%U$ - *

Or:

To set RUN to an ASCII character: 1. Scan this label: Set RUN

*+/$+XC* *+/$+XC*

2. Scan a label for data from the full ASCII chart in Appendix B, “Full ASCII Chart.” 3. Scan this label: Exit Configuration, Save Settings

*$-* *$ - *

7-31

Page 164

Configuration Commands - IRL SOP (Start of Program Block)

IRL SOP (Start of Program Block) Purpose:

Indicates the beginning of an IRL program download from the host to the reader.

Default:

SI (shift in)

Syntax:

XAdata

Acceptable values for data are: Any ASCII character NUL = disable Scan:

To disable SOP, scan this label: Disable SOP

*$+XA%U$-* *$+XA%U$ - *

Or:

To set SOP to an ASCII character: 1. Scan this label: Set SOP

*+/$+XA* *+/$+XA*

2. Scan a label for data from the full ASCII chart in Appendix B, “Full ASCII Chart.” 3. Scan this label: Exit Configuration, Save Settings

*$-* *$ - *

7-32

Page 165

Configuration Commands - Katakana

7

Katakana Purpose:

Sets the displayed character set to Katakana. You need to specify the entry style (Kana or Ro-maji) and assign function keys to switch between US ASCII and Katakana. See “Using the Katakana Character Set” in Chapter 5 for more information.

Default:

Entry style = Kana US key = F1 Katakana key = F1

Syntax: Entry Style

LAdata

Acceptable values for data are: 0 1

Syntax: US Function Key

Kana Ro-maji

LBdata

Acceptable values for data are: 1 thru 9 1 = F1 2 = F2 3 = F3 4 = F4 5 = F5

Syntax: Katakana Function Key

LCdata

Acceptable values for data are: 1 thru 9 1 = F1 2 = F2 3 = F3 4 = F4 5 = F5

Scan:

6 = F6 7 = F7 8 = F8 9 = F9

6 = F6 7 = F7 8 = F8 9 = F9

1. To set the entry style, scan one of these labels: Kana Entry Style

Ro-maji Entry Style

*$+LA0$-*

*$+LA1$-*

*$+LA0$-*

*$+LA1$-*

7-33

Page 166

Configuration Commands - Katakana

2. Optional. To set the US function key, scan one of these labels: US ASCII key F1

US ASCII key F6

*$+LB1$-*

*$+LB6$-*

US ASCII key F2

US ASCII key F7

*$+LB2$-*

*$+LB7$-*

US ASCII key F3

US ASCII key F8

*$+LB3$-*

*$+LB8$-*

US ASCII key F4

US ASCII key F9

*$+LB4$-*

*$+LB9$-*

*$+LB1$-*

*$+LB2$-*

*$+LB3$-*

*$+LB4$-*

*$+LB6$-*

*$+LB7$-*

*$+LB8$-*

*$+LB9$-*

US ASCII key F5

*$+LB5$-* *$+LB5$-*

3. Optional, to set the Katakana function key, scan one of these labels: Katakana key F1

*$+LC1$-*

*$+LC6$-*

*$+LC1$-*

*$+LC6$-*

Katakana key F2

Katakana key F7

*$+LC2$-*

*$+LC7$-*

*$+LC2$-*

*$+LC7$-*

Katakana key F3

Katakana key F8

*$+LC3$-*

*$+LC8$-*

*$+LC3$-*

7-34

Katakana key F6

*$+LC8$-*

Page 167

Configuration Commands - Katakana

7

Katakana key F4

Katakana key F9

*$+LC4$-*

*$+LC9$-*

*$+LC4$-*

*$+LC9$-*

Katakana key F5

*$+LC5$-* *$+LC5$-*

Note:

When the function key for US ASCII and Katakana are the same key, pressing the function key toggles between the two character sets. By default, F1 is set for both character sets.

7-35

Page 168

Configuration Commands - LRC (Longitudinal Redundancy Check)

LRC (Longitudinal Redundancy Check) Purpose:

The Longitudinal Redundancy Check character is an error checking character that you can append to transmitted and received blocks of data. The host software must support LRC.

Default:

Disabled

Syntax:

IFdata

Acceptable values for data are: 0 1 Scan:

Disabled Enabled

Scan one of these labels: Disable LRC

*$+IF0$-* *$+IF0$-*

Enable LRC

*$+IF1$-* *$+IF1$-*

7-36

Page 169

Configuration Commands - NEG (Negative Acknowledgment)

7

NEG (Negative Acknowledgment) Purpose:

Indicates a negative acknowledgment to a transmitted message. NEG and AFF must both be defined.

Default:

NUL (disabled)

Syntax:

PHdata

Acceptable values for data are: Any ASCII character NUL = disable Scan:

To disable NEG, scan this label: Disable NEG

*$+PH%U$-* *$+PH%U$ - *

Or:

To set NEG to an ASCII character: 1. Scan this label: Set NEG

*+/$+PH* *+/$+PH*

2. Scan a label for data from the full ASCII chart in Appendix B, “Full ASCII Chart.” 3. Scan this label: Exit Configuration, Save Settings

*$-* *$ - *

7-37

Page 170

Configuration Commands - Parity

Parity Purpose:

Sets the error checking for data transmissions.

Default:

Even

Syntax:

IBdata

Acceptable values for data are: 0 1 2 Scan:

Disabled Even Odd

Scan one of these labels: Disabled

Odd

*$+IB0$-*

*$+IB2$-*

*$+IB0$-* Even

*$+IB1$-* *$+IB1$-*

Or:

To set parity to Mark, set these options: • 7 data bits • disabled parity • 2 stop bits To set parity to Space, set these options: • 8 data bits • disabled parity • 1 stop bit

7-38

*$+IB2$-*