Page 151

Configuration Commands - EOM (End of Message)

7

EOM (End of Message) Purpose:

Defines the EOM character that is attached to the end of a data block to indicate the end of data transmission to and from the reader. The transmit and receive EOM can be defined together or separately.

Default:

CR LF

Syntax:

PFdata PIdata PJdata

Transmit and Receive EOM same Transmit EOM Receive EOM data can be one or two ASCII characters NUL NUL = disable Scan:

1. Scan one of these labels: Transmit and Receive

*+/$+PF* *+/$+PF*

Transmit only

*+/$+PI* *+/$+PI*

Receive only

*+/$+PJ* *+/$+PJ*

2. Scan one or two bar codes for data from the full ASCII chart in Appendix B, “Full ASCII Chart.” 3. Scan this bar code: Exit Configuration, Save Settings

*$-* *$ - *

7-19

Page 152

Configuration Commands - Full ASCII

Full ASCII Purpose:

Allows the reader to accept ASCII characters as data or commands.

Default:

Disabled

Syntax:

RBdata

Acceptable values for data are: 0 1 Scan:

Disabled Enabled

Scan one of these labels: Disable Full ASCII

*$+RB0$-* *$+RB0$-*

7-20

Enable Full ASCII

*$+RB1$-*

*$+RB1$-*

Page 153

Configuration Commands - Intercharacter Delay

7

Intercharacter Delay Purpose:

Defines the length of time the reader waits before sending each character to the host. It modifies outgoing data only by slowing the transmission speed. A character delay can be useful when your a communicating through modems with full-duplex operation.

Default:

0 msec

Syntax:

IDdata

Acceptable values for data are: 0 1 2 3 4 5 6 7 Scan:

0 msec 1 msec 2 msec 5 msec 10 msec 20 msec 50 msec 100 msec

Scan one of these labels: 0 msec

*$+ID0$-*

10 msec

*$+ID4$-*

*$+ID0$-*

*$+ID4$-*

1 msec

20 msec

*$+ID1$-*

*$+ID5$-*

2 msec

50 msec

*$+ID2$-*

*$+ID6$-*

5 msec

100 msec

*$+ID1$-*

*$+ID2$-*

*$+ID3$-* *$+ID3$-*

*$+ID5$-*

*$+ID6$-*

*$+ID7$-*

*$+ID7$-*

7-21

Page 154

Configuration Commands - Interface

Interface Purpose:

Defines the communications interface.

Default:

RS-232

Syntax:

IKdata

Acceptable values for data are: 0 1 Scan:

RS-232 RS-422/RS-485

Scan one of these labels: RS-232

RS-422/485

*$+IK0$-*

*$+IK1$-*

*$+IK0$-*

7-22

*$+IK1$-*

Page 155

Configuration Commands - Interleaved 2 of 5 (I 2 of 5)

7

Interleaved 2 of 5 (I 2 of 5) Purpose:

Enables or disables decoding of Interleaved 2 of 5 symbology. Enabling I 2 of 5 automatically disables 2 of 5.

Default:

Variable length

Syntax:

CAdata

Acceptable values for data are: 0 2-32 98 99 Scan:

Disabled Specified Length - must be even increments Case code Variable length

Scan one of these labels: Disabled

*$+CA0$-* *$+CA0$-*

Variable Length

*$+CA99$-*

*$+CA99$-*

Case code

*$+CA98$-* *$+CA98$-*

Or:

To use a specific label length: 1. Scan this label: Specified Length

*+/$+CA* *+/$+CA*

2. Scan an even number between 2 and 32 from the full ASCII chart in Appendix B, “Full ASCII Chart.” 3. Scan this label:

*$-* *$ -*

7-23

Page 156

Configuration Commands - IRL BAK (Bad Program Acknowledge)

IRL BAK (Bad Program Acknowledge) Purpose:

Character sent by the reader to the host to indicate that an IRL program cannot be successfully downloaded.

Default:

BEL

Syntax:

ZBdata

Acceptable values for data are: Any ASCII character NUL = disable Scan:

To disable BAK, scan this label: Disable BAK

*$+ZB%U$-* *$+ZB%U$ - *

Or:

To set BAK to an ASCII character: 1. Scan this label: Set BAK

*+/$+ZB$-* *+/$+ZB$ - *

2. Scan a label for data from the full ASCII chart in Appendix B, “Full ASCII Chart.” 3. Scan this label: Exit Configuration, Save Settings

*$-* *$ - *

7-24

Page 157

Configuration Commands - IRL END (End of Program)

7

IRL END (End of Program) Purpose:

Indicates the last block of an IRL program when downloading to the reader.

Default:

SO (shift out)

Syntax:

XDdata

Acceptable values for data are: Any ASCII character NUL = disable Scan:

To disable END, scan this label: Disable END

*$+XD%U$-* *$+XD%U$ - *

Or:

To set END to an ASCII character: 1. Scan this label: Set END

*+/$+XD* *+/$+XD*

2. Scan a label for data from the full ASCII chart in Appendix B, “Full ASCII Chart.” 3. Scan this label: Exit Configuration, Save Settings

*$-* *$ - *

7-25

Page 158

Configuration Commands - IRL EOF (End of File)

IRL EOF (End of File) Purpose:

Indicates the end of an IRL program file when downloading an IRL program to the reader.

Default:

NUL (disabled)

Syntax:

FAdata

Acceptable values for data are: Any ASCII character NUL = disable Scan:

To disable EOF, scan this label: Disable EOF

*$+FA%U$-* *$+FA%U$ - *

Or:

To set EOF to an ASCII character: 1. Scan this label: Set EOF

*+/$+FA* *+/$+FA*

2. Scan a label for data from the full ASCII chart in Appendix B, “Full ASCII Chart.” 3. Scan this label: Exit Configuration, Save Settings

*$-* *$ - *

7-26

Page 159

Configuration Commands - IRL EOP (End of Program Block)

7

IRL EOP (End of Program Block) Purpose:

Indicates the end of an IRL program block when downloading from the host to the reader.

Default:

SYN (synchronous idle)

Syntax:

XBdata

Acceptable values for data are: Any ASCII character NUL = disable Scan:

To disable EOP, scan this label: Disable EOP

*$+XB%U$-* *$+XB%U$ - *

Or:

To set EOP to an ASCII character: 1. Scan this label: Set EOP

*+/$+XB* *+/$+XB*

2. Scan a label for data from the full ASCII chart in Appendix B, “Full ASCII Chart.” 3. Scan this label: Exit Configuration, Save Settings

*$-* *$ - *

7-27

Page 160

Configuration Commands - IRL EOR (End of Record)

IRL EOR (End of Record) Purpose:

Indicates the end of an IRL program record (block) when downloading an IRL program to the reader.

Default:

NUL NUL (disabled)

Syntax:

FBdata

Acceptable values for data are: Any two ASCII characters NUL NUL = disable Scan:

To disable EOR, scan this label: Disable EOR

*$+FB%U$-* *$+FB%U$ - *

Or:

To set EOR to an ASCII character: 1. Scan this label: Set EOR

*+/$+FB* *+/$+FB*

2. Scan a label for data from the full ASCII chart in Appendix B, “Full ASCII Chart.” 3. Scan this label: Exit Configuration, Save Settings

*$-* *$ - *

7-28