Page 141
Configuration Commands - Character Set
7
Character Set Purpose:
Determines the language used to display characters.
Default:
US ASCII
Syntax:
DXdata
Acceptable values for data are: 0 1 2 3 4 5 6 7 8 Scan:
US ASCII French German United Kingdom Danish Swedish Italian Spanish Japanese Katakana
Scan one of these labels: US-ASCII
Swedish
*$+DX0$-*
*$+DX5$-*
French
Italian
*$+DX0$-*
*$+DX1$-*
*$+DX5$-*
*$+DX6$-*
*$+DX1$-*
*$+DX6$-*
German
Spanish
*$+DX2$-*
*$+DX7$-*
*$+DX2$-*
*$+DX7$-*
United Kingdom
Japanese Katakana
*$+DX3$-*
*$+DX8$-*
*$+DX3$-*
*$+DX8$-*
Danish
*$+DX4$-* *$+DX4$-*
7-9
Page 142
Configuration Commands - Codabar
Codabar Purpose:
Enables or disables decoding of Codabar symbology.
Default:
Standard with ABCD start/stop characters
Syntax:
CDdata data must be 2 digits. Acceptable values are: First digit: 0 1 2 3
Disabled ABC Standard Concatenated
Second digit: 0 1 2
No start/stop transmitted ABCD start/stop transmitted DC1 - DC4 start/stop transmitted
Note: data = 10 is not allowed Scan:
To disable Codabar, scan this label: Disable Codabar
*$+CD00$-* *$+CD00$-*
Or:
To use Codabar ABC, scan one of these labels: ABC, ABCD Start/Stop
ABC, DC1-DC4 Start/Stop
*$+CD11$-*
*$+CD12$-*
*$+CD11$-*
7-10
*$+CD12$-*
Page 143
Configuration Commands - Codabar
Or:
7
To use Codabar Standard, scan one of these labels: Standard, No Start/Stop
Standard, DC1-DC4 Start/Stop
*$+CD20$-*
*$+CD22$-*
*$+CD20$-*
*$+CD22$-*
Standard, ABCD Start/Stop
*$+CD21$-* *$+CD21$-*
Or:
To use Codabar Concatenated, scan one of these labels: Concatenated, No Start/Stop
Concatenated, DC1-DC4 Start/Stop
*$+CD30$-*
*$+CD32$-*
*$+CD30$-*
*$+CD32$-*
Concatenated, ABCD Start/Stop
*$+CD31$-* *$+CD31$-*
7-11
Page 144
Configuration Commands - Code 11
Code 11 Purpose:
Enables or disables decoding of Code 11 symbology.
Default:
Enabled with one check digit
Syntax:
CGdata
Acceptable values for data are: 0 1 2 Scan:
Disabled One check digit Two check digits
Scan one of these labels: Disable Code 11
*$+CG0$-* *$+CG0$-*
1 check digit
*$+CG1$-* *$+CG1$-*
7-12
2 check digits
*$+CG2$-*
*$+CG2$-*
Page 145
Configuration Commands - Code 39
7
Code 39 Purpose:
Enables or disables the coding of Code 39 symbology.
Default:
Enabled, no check digit
Syntax:
CBdata data must be 2 digits. Acceptable values are: First digit: 0 1 2 3
Disabled Enabled, no check digit Enabled, with check digit HIBC
Second digit: 0 1 Scan:
Don’t transmit check digit Transmit check digit
Scan one of these labels: Disable Code 39
HIBC
*$+CB00$-*
*$+CB31$-*
Enable Code 39, Do Not Transmit Check Digit
Enable Code 39, Transmit Check Digit
*$+CB20$-*
*$+CB21$-*
*$+CB00$-*
*$+CB20$-*
*$+CB31$-*
*$+CB21$-*
Enable Code 39 Without Check Digit
*$+CB10$-* *$+CB10$-*
7-13
Page 146
Configuration Commands - Code 93
Code 93 Purpose:
Enables or disables decoding of Code 93 symbology.
Default:
Enabled
Syntax:
CFdata
Acceptable values for data are: 0 1 Scan:
Disabled Enabled
One of these labels: Disable Code 93
*$+CF0$-* *$+CF0$-*
7-14
Enable Code 93
*$+CF1$-*
*$+CF1$-*
Page 147
Configuration Commands - Code 128
7
Code 128 Purpose:
Enables or disables decoding of Code 128 symbology
Default:
Enabled
Syntax:
CHdata
Acceptable values for data are: 0 1 2 Scan:
Disabled Standard Enable UCC-128 (decodes UCC-128 enhancements if present)
Scan one of these labels: Disable Code 128
Enable UCC-128
*$+CH0$-*
*$+CH2$-*
*$+CH0$-*
*$+CH2$-*
Standard
*$+CH1$-* *$+CH1$-*
7-15
Page 148
Configuration Commands - Computer Response Required Mode (CRRM)
Computer Response Required Mode (CRRM) Purpose:
Determines if the reader requires a response from the host before the reader accepts any more data.
Default:
Disabled
Syntax:
PBdata
Acceptable values for data are: 0 1 Scan:
Disabled Enabled
Scan one of these labels: Disable CRRM
Enable CRRM
*$+PB0$-*
*$+PB1$-*
*$+PB0$-*
7-16
*$+PB1$-*
Page 149
Configuration Commands - Data Bits
7
Data Bits Purpose:
Sets the number of data bits the reader uses when communicating with another device.
Default:
7
Syntax:
IIdata
Acceptable values for data are: 7 8 Scan:
7 data bits 8 data bits
Scan one of these labels: 7 Data Bits
8 Data Bits
*$+II7$-*
*$+II8$-*
*$+II7$-*
*$+II8$-*
7-17
Page 150
Configuration Commands - Display Setting
Display Setting Purpose:
Determines how the reader displays and formats data.
Default:
Buffered
Syntax:
ODdata
Acceptable values for data are: 0 1 Scan:
Buffered Transparent
Scan one of these labels: Buffered
Transparent
*$+OD0$-*
*$+OD1$-*
*$+OD0$-*
7-18
*$+OD1$-*