The text of a manual · part 14 of 31

9560 Transaction Manager User's Manual, pages 131 to 140

Pages 131 to 140 of 309

The original document is the PDF (1.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Intermec 9560

Page 131

Configuring the 9560

6

Configuration Prompts for 1x20 Display (continued) EOP = SYN

SYN ANY ASCII CHARACTER

RUN = DC2

DC2 ANY ASCII CHARACTER

END = SO

SO ANY ASCII CHARACTER

PSS = CR

CR ANY ASCII CHARACTER

PAK = RS

RS ANY ASCII CHARACTER

BAK = BEL

BEL ANY ASCII CHARACTER

6-25

Page 132

This page is a scan with no text; see it in the PDF.

Page 133

7 Configuration Commands

A F

B

K

G

C

L

H

D

M

I

P U

Q V

R W

E N

J

S

O

X

T Y

C ap s $ 7

/ , Z

4

8

1

5

9

2

6

0

3

B ks p

S pa ce

In

. E n te r te rm

F 1 F 2 F 3 F 4 F 5

F 6 F 7 F 8 F 9

9 F10 5 6 0 ec

Page 134

This page is a scan with no text; see it in the PDF.

Page 135

Configuration Commands

7

This chapter provides an alphabetical listing and description of all configuration commands the 9560 recognizes.

Using the Configuration Commands This chapter provides the following information on each configuration command: •

Description of the command

•

Syntax for sending the command from a host computer, executing the command in an IRL program, or entering the command from the reader or terminal keypad.

•

Bar code label for scanning the command

For more information on configuring the reader, see Chapter 6, “Configuring the 9560.” Note: IRL commands are grouped together alphabetically under IRL Name, where name is the command name.

7-3

Page 136

Configuration Commands - ADDR (Address, Multidrop)

ADDR (Address, Multidrop) Purpose:

Defines the address of the communication port when using a Mutli-Drop protocol. Each address has unique POL and SEL characters, which are automatically set when the address is configured.

Default:

A

Syntax:

HCdata

Acceptable values for data are: A - Z, or 0 - 5 NUL = disable Scan:

1. Scan the following label: Enter Accumulate/Change Configuration/Address

*+/$+HC* *+/$+HC*

2. Scan a bar code for data from the full ASCII chart in Appendix B, “Full ASCII Chart.” 3. Scan the following label: Exit Configuration, Save Settings

*$-* *$ - *

7-4

Page 137

Configuration Commands - AFF (Affirmative Acknowledgment)

7

AFF (Affirmative Acknowledgment) Purpose:

Enables or disables the handshake event that is an affirmative acknowledgment to a message. AFF and NEG must both be enabled.

Default:

NUL (disabled)

Syntax:

PGdata

Acceptable values for data are: Any ASCII character NUL = disable Scan:

To disable AFF, scan this label: Disable AFF

*$+PG%U$-* *$+PG%U$ -*

Or:

To set the AFF to an ASCII character: 1. Scan the following label: Enter Accumulate/Change Configuration/AFF

*+/$+PG* *+/$+PG*

2. Scan a bar code for data from the full ASCII chart in Appendix B, “Full ASCII Chart.” 3. Scan the following label: Exit Configuration, Save Settings

*$-* *$ - *

7-5

Page 138

Configuration Commands - Append Time to Data

Append Time to Data Purpose:

Determines if the time is added after the data for transmission.

Default:

Not appended

Syntax:

DEdata

Acceptable values for data are: 0 1 Scan:

Time not appended Time appended

Scan one of these labels: Disable Append Time

*$+DE0$-* *$+DE0$-*

Enable Append Time

*$+DE1$-* *$+DE1$-*

7-6

Page 139

Configuration Commands - Baud Rate

7

Baud Rate Purpose:

Defines the data transfer speed. It must match the baud rate of the device (host) that the reader is communicating with. For Polling Mode D, the baud rate must be 1200 or higher. For Multi-Drop protocol, the baud rate must be 2400 or higher.

Default:

9600

Syntax:

IAdata

Acceptable values for data are: 0 1 2 3 4 5 6 7 Scan:

110 300 600 1200 2400 4800 9600 19200

Scan one of these labels: 110

2400

*$+IA0$-*

*$+IA4$-*

*$+IA0$-*

*$+IA4$-*

300

4800

*$+IA1$-*

*$+IA5$-*

600

9600

*$+IA2$-*

*$+IA6$-*

1200

19200

*$+IA3$-*

*$+IA7$-*

*$+IA1$-*

*$+IA2$-*

*$+IA3$-*

*$+IA5$-*

*$+IA6$-*

*$+IA7$-*

7-7

Page 140

Configuration Commands - Beeper Volume

Beeper Volume Purpose:

Adjusts the volume of beeps from the reader. Set the beep volume according to your preference and work environment.

Default:

Loudest level

Syntax:

BVdata

Acceptable values for data are: 0 to 9, where: 0 Softest level 3 Medium level 7 Loudest level 8 Lower volume 9 Raise volume Scan:

To raise or lower the beeper volume, scan one of these labels: Louder

Softer

*$+BV9$-*

*$+BV8$-*

*$+BV9$-*

Or:

To define a specific volume, scan one of these labels: Level 0 (softest)

Level 4

*$+BV0$-*

*$+BV4$-*

Level 1

Level 5

*$+BV1$-*

*$+BV5$-*

Level 2

Level 6

*$+BV2$-*

*$+BV6$-*

Level 3 (medium)

Level 7 (loudest)

*$+BV3$-*

*$+BV7$-*

*$+BV0$-*

*$+BV1$-*

*$+BV2$-*

*$+BV3$-*

7-8

*$+BV8$-*

*$+BV4$-*

*$+BV5$-*

*$+BV6$-*

*$+BV7$-*