Page 171
Configuration Commands - POL (Poll)
7
POL (Poll) Purpose:
Solicits or requests data from a polled device.
Default:
NUL (disabled)
Syntax:
HBdata
Acceptable value for data is: Any ASCII character Scan:
To disable POL, scan this label: Disable POL
*$+HB%U$-* *$+HB%U$ - *
Or:
To set POL to an ASCII character: 1. Scan this label: Set POL
*+/$+HB* *+/$+HB*
2. Scan a label for data from the full ASCII chart in Appendix B, “Full ASCII Chart.” 3. Scan this label: Exit Configuration, Save Settings
*$-* *$ - *
7-39
Page 172
Configuration Commands - Preamble A Required
Preamble A Required Purpose:
Adds the Preamble characters to the beginning of the data before transmitting the data.
Default:
Not required
Syntax:
OAdata
Acceptable values for data are: 0 1 Scan:
Not required Required
Scan one of these labels: Not required
Required
*$+OA0$-*
*$+OA1$-*
*$+OA0$-*
7-40
*$+OA1$-*
Page 173
Configuration Commands - Protocol
7
Protocol Purpose:
Determines how the reader communicates with the host through the DTE interface.
Default:
Point-to-Point
Syntax:
PAdata
Acceptable values for data are: 0 1 2 3 4 Scan:
User-Defined Point-to-Point Polling Mode D Multi-Drop User-Defined Multi-Drop
Scan one of these labels: User Defined
*$+PA0$-*
Multi-Drop
*$+PA3$-*
*$+PA0$-*
*$+PA3$-*
Point-to-Point
User Defined Multi-Drop
*$+PA1$-*
*$+PA4$-*
*$+PA1$-*
*$+PA4$-*
Polling Mode D
*$+PA2$-* *$+PA2$-*
7-41
Page 174
Configuration Commands - Records per Block
Records per Block Purpose:
Defines the maximum number of data records transmitted per block of data. Usually files are transmitted record by record. You must select the communications protocol before setting the parameters that define the protocol.
Default:
All records within block
Syntax:
FCdata
Acceptable values for data are: 0 1-99 Scan:
All records within block Number of records per block
To set to all records, scan this label: All
*$+FC0$-* *$+FC0$-*
Or:
To set the number of records per block to 1 through 99: 1. Scan this label: Set Records per Block
*+/$+FC* *+/$+FC*
2. Scan a label for 1 through 99 from the full ASCII chart in Appendix B, “Full ASCII Chart.” 3. Scan this label: Exit Configuration, Save Settings
*$-* *$ - *
7-42
Page 175
Configuration Commands - REQ (Request for Acknowledgment)
7
REQ (Request for Acknowledgment) Purpose:
Enables or disables a request for a repeat handshake event. If REQ is enabled, AFF and NEG must also be enabled.
Default:
Disabled
Syntax:
PDdata
Acceptable values for data are: Any ASCII character NUL = disable Scan:
To disable REQ, scan this label: Disable REQ
*$+PD%U$-* *$+PD%U$ - *
Or:
To set REQ to an ASCII character: 1. Scan this label: Set REQ
*+/$+PD* *+/$+PD*
2. Scan a label for data from the full ASCII chart in Appendix B, “Full ASCII Chart.” 3. Scan this label: Exit Configuration, Save Settings
*$-* *$ - *
7-43
Page 176
Configuration Commands - RES (Reset)
RES (Reset) Purpose:
Enables or disables a reset event.
Default:
NUL (disabled)
Syntax:
PCdata
Acceptable value for data is: Any ASCII character NUL = disable Scan:
To disable RES, scan this label: Disable RES
*$+PC%U$-* *$+PC%U$ - *
Or:
To set RES to an ASCII character: 1. Scan this label: Set RES
*+/$+PC* *+/$+PC*
2. Scan a label for data from the full ASCII chart in Appendix B, “Full ASCII Chart.” 3. Scan this label: Exit Configuration, Save Settings
*$-* *$ - *
7-44
Page 177
Configuration Commands - Resume IRL
7
Resume IRL Purpose:
Sets the scanner to resume an interrupted IRL program at power up. If the program was completed, it starts at the beginning.
Default:
0 (disabled)
Syntax:
XGdata
Acceptable values for data are: 0 1 Scan:
Disabled Enabled
Scan one of these labels: Disable Resume IRL
Enable Resume IRL
*$+XG0$-*
*$+XG1$-*
*$+XG0$-*
*$+XG1$-*
7-45
Page 178
Configuration Commands - Scanner Timeout
Scanner Timeout Purpose:
Defines the maximum length of time the scanner stays on after the trigger is pulled or after a label is passed through the slot.
Default:
No timeout
Syntax:
SAdata or IHdata
Acceptable values for data are: 0 1 - 60 Scan:
No timeout 1 - 60 msec
1. Scan this label: Set Scanner Timeout
*+/$+SA* *+/$+SA*
2. Scan a label for 0 through 60 from the full ASCII chart in Appendix B, “Full ASCII Chart.” 3. Scan this label: Exit Configuration, Save Settings
*$-* *$ - *
7-46
Page 179
Configuration Commands - Scanner Operation
7
Scanner Operation Purpose:
Defines how the scanner operates when the trigger is pulled. One-shot mode requires you to pull the trigger each time you want to scan a bar code. The scanner turns off once it scans the bar code. Automatic mode allows you to pull the trigger once and scan several bar codes. The scanner turns off when you release the trigger.
Default:
One shot
Syntax:
SBdata
Acceptable values for data are: 0 1 Scan:
One-shot Auto-trigger
Scan one of these labels: One Shot
Auto Trigger
*$+SB0$-*
*$+SB1$-*
*$+SB0$-*
*$+SB1$-*
7-47
Page 180
Configuration Commands - SEL (Select)
SEL (Select) Purpose:
Defines the character that requests permission for the controller to send data to the polled device.
Default:
NUL (disabled)
Syntax:
HAdata
Acceptable value for data is: Any ASCII character Scan:
To disable SEL, scan this label: Disable SEL
*$+HA%U$-* *$+HA%U$ - *
Or:
To set SEL to an ASCII character: 1. Scan this label: Set SEL
*+/$+HA* *+/$+HA*
2. Scan a label for data from the full ASCII chart in Appendix B, “Full ASCII Chart.” 3. Scan this label: Exit Configuration, Save Settings
*$-* *$ - *
7-48