Page 111

Configuring the 9560

6

Operating Parameters Configuration Settings Parameter

Options

Beep volume

0 (softest) 8 (lower volume)

3 (medium) 9 (raise volume)

Display mode

Buffered

Transparent

Character Set

US-ASCII Danish Katakana (Japanese)

French Swedish

Computer Response Required Mode

Enable (required)

Disable

Preamble A required

Enable

Disable

Scanner timeout

0 (no timeout)

1 - 60 msec

Scanner mode

One shot

Auto-trigger

Trigger event

Level

Edge

Append time to data

Enable

Disable

Time in Seconds

Enable

Disable

Resume IRL on power-up

Enable

Disable

7 (loudest)

German Italian

United Kingdom Spanish

Default settings are in bold text.

6-5

Page 112

9560 Transaction Manager User’s Manual

Communications Protocol Configuration Settings Point-to-Point Parameters

Options

Point-to-Point (Default Protocol)

Interface

RS-232

RS-422/RS-485

Terminal setting

Buffered, Block

Transparent

XON/XOFF

NUL/NUL

Any ASCII character

Baud rate

110 2400

Parity

Nonbuffered Full-Duplex

Nonbuffered Half-Duplex

300 4800

600 9600

1200 19200

Even

Odd

Disable

Data bits

7

8

Stop bits

1

2

Timeout Delay

5 msec 10 sec

100 msec 20 sec

500 msec 40 sec

2 sec 60 sec

Intercharacter Delay

0 msec 10 msec

1 msec 20 msec

2 msec 50 msec

5 msec 100 msec

Turnaround Delay

0 msec 10 msec

1 msec 20 msec

2 msec 50 msec

5 msec 100 msec

AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA

Polling Mode D Parameters

Options

Interface

RS-232

RS-422/RS-485 (single device)

Terminal setting

Buffered

Transparent

Baud rate

2400

4800

Default settings are in bold text.

6-6

9600

19200 continued

Page 113

Configuring the 9560

6

Communications Protocol Configuration Settings (continued) Multi-Drop Parameters

Options

Interface

RS-222/RS485

Address character

A

A to Z, 0 to 5

Terminal setting

Buffered

Transparent

XON/XOFF

NUL/NUL

Any ASCII character

Baud rate

2400

4800

9600

Parity

Even

Odd

Disable

Data bits

7

8

Stop bits

1

2

Timeout Delay

5 msec 10 sec

100 msec 20 sec

500 msec 40 sec

2 sec 60 sec

Intercharacter Delay

0 msec 10 msec

1 msec 20 msec

2 msec 50 msec

5 msec 100 msec

Turnaround Delay

0 msec 10 msec

1 msec 20 msec

2 msec 50 msec

5 msec 100 msec

19200

Default settings are in bold text.

6-7

Page 114

9560 Transaction Manager User’s Manual

User-Defined and User-Defined Multi-Drop Protocol Configuration Settings Parameters

Options

Interface

RS-232

RS-422/RS-485

Multi-drop default

Terminal setting

Buffered, Block

Transparent

Nonbuffered Full-Duplex

Nonbuffered Half-Duplex

XON/XOFF

NUL/NUL

Any ASCII character

Baud rate

110 2400

300 4800

600 9600

1200 19200

Parity

Even

Odd

Disable

Data bits

7

8

Stop bits

1

2

Timeout Delay

5 msec 10 sec

100 msec 20 sec

500 msec 40 sec

2 sec 60 sec

Intercharacter Delay

0 msec 10 msec

1 msec 20 msec

2 msec 50 msec

5 msec 100 msec

Turnaround Delay

0 msec 10 msec

1 msec 20 msec

2 msec 50 msec

5 msec 100 msec

Interface

RS-232

RS-422/RS-485

LRC

Disabled

POL

NUL

SEL

NUL

RES

NUL

REQ

NUL

AFF

NUL

NEG

NUL

SOM

NUL

EOM

CR LF

EOR

NUL, NUL

Records per block

1

EOF

NUL

SOP

SI

EOP

SYN

Default settings are in bold text.

6-8 continued

Page 115

Configuring the 9560

6

User-Defined and User-Defined Multi-Drop Protocol Configuration Settings (continued) RUN

DC2

END

SO

PSS

CR

PAK

RS

BAK

BEL

Default settings are in bold text.

Note: For User-Defined Multi-Drop protocol, the interface default is RS-422/RS485.

6-9

Page 116

9560 Transaction Manager User’s Manual

Using Batch Configuration To configure several readers identically, you can print a bar code “menu” with several parameters per label. A label can contain up to 48 characters, but this many characters may not scan easily. Each label should include the following, in this order: •

Start character (*). Intermec printers automatically generate this start character.

•

The Enter Configuration command ($+).

•

Desired configuration commands and applicable data. See Chapter 7, “Configuration Commands.”

•

The Exit Configuration command ($-).

•

Stop character (*). Intermec printers automatically generate this stop character.

Batch Configuration Example To configure the reader with Point-to-Point protocol using 2400 baud, scan the following batch label:

*$+PA1IA4$-* *$+PA1IA4$-*

The label contains the following information:

9560-53U

6-10

Page 117

Configuring the 9560

6

Downloading Configuration Commands You can download any configuration command from a host computer. You can combine commands into a single downloaded string of up to 254 characters. The string must use the host communication protocol currently in effect. Each command string should include the following, in this order: •

Enter Configuration command ($+)

•

Desired configuration commands and data

•

Exit Configuration command ($-)

If you send a string of configuration commands that contains an invalid command, the reader executes the last valid command and stops processing the string. The reader remains in Configuration mode and recognizes only these two commands: •

Exit Configuration ($-) to act on the valid commands

•

Reset (-.) to exit without acting on the commands

The data string for a specific command may include another recognized command, such as CR, LF, or HT. If you want the reader to treat the command as data, you must precede the command with the Command Override (DLE). For more information, see “Command Override” in Chapter 8.

Download Command Example As noted above, each command must include the Enter Configuration command ($+) and the Exit Configuration command ($-). For example, to set the 9560’s baud rate at 9600, send this data string: $+IA6$where: $+ enters Configuration mode

IA identifies the baud rate parameter

6 selects the 9600 option

$- exits Configuration mode and updates the parameter.

6-11

Page 118

9560 Transaction Manager User’s Manual

Using Prompting Configuration Mode In Prompting Configuration, the 9560 prompts you step by step through all configuration tasks. The reader displays a prompt for each option within each parameter, beginning with the current setting. You can change each setting or accept it as is. The following pages explain how to enter Prompting Configuration, how to move around, and how to exit. The Standard Display Prompts table and LargeType Display Prompts table list the configuration prompts and their options. The options are the same for the standard and large-type displays, but the prompts are different.

Entering Prompting Configuration Mode 1. Make sure that the reader is plugged in and the power is on. 2. If the reader is connected to a CRT terminal, set the reader for buffered or transparent display to match the terminal setting. Scan one of these labels: Buffered

Transparent

*$+OC1$-*

*$+OC2$-*

*$+OC1$-*

*$+OC2$-*

3. Enter Prompting Configuration mode. Press Ctrl E from the keyboard or scan this label: Enter Prompting Configuration

*$+$+* *$+$+*

The 9560 sounds one low beep and the reader displays the first Prompting Configuration screen. <?>HELP <CR>START Use the following sections and tables to change your settings in Prompting Configuration mode.

6-12

Page 119

Configuring the 9560

6

Moving Around in Prompting Configuration Mode You can move through all the parameters of a particular task or move through the options within each parameter. To move through Prompting Configuration mode 1. Decide which task to perform: select bar codes, set operating parameters, or define host protocols. 2. Press Enter until the prompt for that task appears on the screen or terminal display. Pressing Enter moves you to the next configuration prompt. 3. Press Space until the option you want appears on the screen. Pressing Space cycles through the choices for the current prompt. 4. Press Enter to accept the currently displayed option. The prompt for the next parameter is displayed. Type

Or Scan This Label

To Do This

Ctrl E¤

*$+$+*

Enter Prompting Configuration mode.

*%+*

Move forward from one parameter to the next.

*%-*

Move backward from one parameter to the previous one.

*%/*

Move through the parameter options. To select the displayed option, press Enter. The new value is stored in the buffer until you exit Prompting Configuration mode.

*$+$+* Enter

*%+* Bksp or Del

*%-* Space

*%b/* Ctrl P

?

Treat the next character entered as data. You can enter control characters into configuration command strings.

*%J*

Enter Help mode.

*$-*

Exit Prompting Configuration mode and save your changes.

* *

Exit Prompting Configuration mode without saving your changes.

*?* Esc

*$-* Ctrl Z

*-.*

Note: You must set the 9560 for transparent or buffered display if you are using a CRT.

6-13

Page 120

9560 Transaction Manager User’s Manual

Finding Help in Prompting Configuration Mode You can use the help command anytime in Prompting Configuration. When you type the question mark ?, the 9560 displays the commands that Prompting Configuration recognizes, one screen at a time. To enter Help, press ?. To move forward in Help, press Enter. To move backward in Help, press Bksp. To exit Help: 1. Scroll through to the beginning or end of the help prompts. 2. At the first prompt, press #. Or, at the last prompt, press Enter. The screen returns to the prompt shown prior to entering Help mode.

Exiting Prompting Configuration Mode You have two ways to exit Prompting Configuration mode: •

To exit and update the parameters, press Esc or scan:

*$-* *$-*

•

To exit without updating the parameters, press Ctrl Z or scan:

*-.* *-.*

Prompting Configuration Mode Example In this example, the reader is not connected to a CRT, and you want to disable Code 93. The reader has the large character 1x20 display. Follow these steps: 1. Scan the Prompting Configuration label. Enter Prompting Configuration

*$+$+* *$+$+*

The 9560 displays this prompt: <?>HELP <CR>START

2. Press Enter. The 9560 displays this prompt:

6-14