Page 111
Configuring the 9560
6
Operating Parameters Configuration Settings Parameter
Options
Beep volume
0 (softest) 8 (lower volume)
3 (medium) 9 (raise volume)
Display mode
Buffered
Transparent
Character Set
US-ASCII Danish Katakana (Japanese)
French Swedish
Computer Response Required Mode
Enable (required)
Disable
Preamble A required
Enable
Disable
Scanner timeout
0 (no timeout)
1 - 60 msec
Scanner mode
One shot
Auto-trigger
Trigger event
Level
Edge
Append time to data
Enable
Disable
Time in Seconds
Enable
Disable
Resume IRL on power-up
Enable
Disable
7 (loudest)
German Italian
United Kingdom Spanish
Default settings are in bold text.
6-5
Page 112
9560 Transaction Manager User’s Manual
Communications Protocol Configuration Settings Point-to-Point Parameters
Options
Point-to-Point (Default Protocol)
Interface
RS-232
RS-422/RS-485
Terminal setting
Buffered, Block
Transparent
XON/XOFF
NUL/NUL
Any ASCII character
Baud rate
110 2400
Parity
Nonbuffered Full-Duplex
Nonbuffered Half-Duplex
300 4800
600 9600
1200 19200
Even
Odd
Disable
Data bits
7
8
Stop bits
1
2
Timeout Delay
5 msec 10 sec
100 msec 20 sec
500 msec 40 sec
2 sec 60 sec
Intercharacter Delay
0 msec 10 msec
1 msec 20 msec
2 msec 50 msec
5 msec 100 msec
Turnaround Delay
0 msec 10 msec
1 msec 20 msec
2 msec 50 msec
5 msec 100 msec
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
Polling Mode D Parameters
Options
Interface
RS-232
RS-422/RS-485 (single device)
Terminal setting
Buffered
Transparent
Baud rate
2400
4800
Default settings are in bold text.
6-6
9600
19200 continued
Page 113
Configuring the 9560
6
Communications Protocol Configuration Settings (continued) Multi-Drop Parameters
Options
Interface
RS-222/RS485
Address character
A
A to Z, 0 to 5
Terminal setting
Buffered
Transparent
XON/XOFF
NUL/NUL
Any ASCII character
Baud rate
2400
4800
9600
Parity
Even
Odd
Disable
Data bits
7
8
Stop bits
1
2
Timeout Delay
5 msec 10 sec
100 msec 20 sec
500 msec 40 sec
2 sec 60 sec
Intercharacter Delay
0 msec 10 msec
1 msec 20 msec
2 msec 50 msec
5 msec 100 msec
Turnaround Delay
0 msec 10 msec
1 msec 20 msec
2 msec 50 msec
5 msec 100 msec
19200
Default settings are in bold text.
6-7
Page 114
9560 Transaction Manager User’s Manual
User-Defined and User-Defined Multi-Drop Protocol Configuration Settings Parameters
Options
Interface
RS-232
RS-422/RS-485
Multi-drop default
Terminal setting
Buffered, Block
Transparent
Nonbuffered Full-Duplex
Nonbuffered Half-Duplex
XON/XOFF
NUL/NUL
Any ASCII character
Baud rate
110 2400
300 4800
600 9600
1200 19200
Parity
Even
Odd
Disable
Data bits
7
8
Stop bits
1
2
Timeout Delay
5 msec 10 sec
100 msec 20 sec
500 msec 40 sec
2 sec 60 sec
Intercharacter Delay
0 msec 10 msec
1 msec 20 msec
2 msec 50 msec
5 msec 100 msec
Turnaround Delay
0 msec 10 msec
1 msec 20 msec
2 msec 50 msec
5 msec 100 msec
Interface
RS-232
RS-422/RS-485
LRC
Disabled
POL
NUL
SEL
NUL
RES
NUL
REQ
NUL
AFF
NUL
NEG
NUL
SOM
NUL
EOM
CR LF
EOR
NUL, NUL
Records per block
1
EOF
NUL
SOP
SI
EOP
SYN
Default settings are in bold text.
6-8 continued
Page 115
Configuring the 9560
6
User-Defined and User-Defined Multi-Drop Protocol Configuration Settings (continued) RUN
DC2
END
SO
PSS
CR
PAK
RS
BAK
BEL
Default settings are in bold text.
Note: For User-Defined Multi-Drop protocol, the interface default is RS-422/RS485.
6-9
Page 116
9560 Transaction Manager User’s Manual
Using Batch Configuration To configure several readers identically, you can print a bar code “menu” with several parameters per label. A label can contain up to 48 characters, but this many characters may not scan easily. Each label should include the following, in this order: •
Start character (*). Intermec printers automatically generate this start character.
•
The Enter Configuration command ($+).
•
Desired configuration commands and applicable data. See Chapter 7, “Configuration Commands.”
•
The Exit Configuration command ($-).
•
Stop character (*). Intermec printers automatically generate this stop character.
Batch Configuration Example To configure the reader with Point-to-Point protocol using 2400 baud, scan the following batch label:
*$+PA1IA4$-* *$+PA1IA4$-*
The label contains the following information:
9560-53U
6-10
Page 117
Configuring the 9560
6
Downloading Configuration Commands You can download any configuration command from a host computer. You can combine commands into a single downloaded string of up to 254 characters. The string must use the host communication protocol currently in effect. Each command string should include the following, in this order: •
Enter Configuration command ($+)
•
Desired configuration commands and data
•
Exit Configuration command ($-)
If you send a string of configuration commands that contains an invalid command, the reader executes the last valid command and stops processing the string. The reader remains in Configuration mode and recognizes only these two commands: •
Exit Configuration ($-) to act on the valid commands
•
Reset (-.) to exit without acting on the commands
The data string for a specific command may include another recognized command, such as CR, LF, or HT. If you want the reader to treat the command as data, you must precede the command with the Command Override (DLE). For more information, see “Command Override” in Chapter 8.
Download Command Example As noted above, each command must include the Enter Configuration command ($+) and the Exit Configuration command ($-). For example, to set the 9560’s baud rate at 9600, send this data string: $+IA6$where: $+ enters Configuration mode
IA identifies the baud rate parameter
6 selects the 9600 option
$- exits Configuration mode and updates the parameter.
6-11
Page 118
9560 Transaction Manager User’s Manual
Using Prompting Configuration Mode In Prompting Configuration, the 9560 prompts you step by step through all configuration tasks. The reader displays a prompt for each option within each parameter, beginning with the current setting. You can change each setting or accept it as is. The following pages explain how to enter Prompting Configuration, how to move around, and how to exit. The Standard Display Prompts table and LargeType Display Prompts table list the configuration prompts and their options. The options are the same for the standard and large-type displays, but the prompts are different.
Entering Prompting Configuration Mode 1. Make sure that the reader is plugged in and the power is on. 2. If the reader is connected to a CRT terminal, set the reader for buffered or transparent display to match the terminal setting. Scan one of these labels: Buffered
Transparent
*$+OC1$-*
*$+OC2$-*
*$+OC1$-*
*$+OC2$-*
3. Enter Prompting Configuration mode. Press Ctrl E from the keyboard or scan this label: Enter Prompting Configuration
*$+$+* *$+$+*
The 9560 sounds one low beep and the reader displays the first Prompting Configuration screen. <?>HELP <CR>START Use the following sections and tables to change your settings in Prompting Configuration mode.
6-12
Page 119
Configuring the 9560
6
Moving Around in Prompting Configuration Mode You can move through all the parameters of a particular task or move through the options within each parameter. To move through Prompting Configuration mode 1. Decide which task to perform: select bar codes, set operating parameters, or define host protocols. 2. Press Enter until the prompt for that task appears on the screen or terminal display. Pressing Enter moves you to the next configuration prompt. 3. Press Space until the option you want appears on the screen. Pressing Space cycles through the choices for the current prompt. 4. Press Enter to accept the currently displayed option. The prompt for the next parameter is displayed. Type
Or Scan This Label
To Do This
Ctrl E¤
*$+$+*
Enter Prompting Configuration mode.
*%+*
Move forward from one parameter to the next.
*%-*
Move backward from one parameter to the previous one.
*%/*
Move through the parameter options. To select the displayed option, press Enter. The new value is stored in the buffer until you exit Prompting Configuration mode.
*$+$+* Enter
*%+* Bksp or Del
*%-* Space
*%b/* Ctrl P
?
Treat the next character entered as data. You can enter control characters into configuration command strings.
*%J*
Enter Help mode.
*$-*
Exit Prompting Configuration mode and save your changes.
* *
Exit Prompting Configuration mode without saving your changes.
*?* Esc
*$-* Ctrl Z
*-.*
Note: You must set the 9560 for transparent or buffered display if you are using a CRT.
6-13
Page 120
9560 Transaction Manager User’s Manual
Finding Help in Prompting Configuration Mode You can use the help command anytime in Prompting Configuration. When you type the question mark ?, the 9560 displays the commands that Prompting Configuration recognizes, one screen at a time. To enter Help, press ?. To move forward in Help, press Enter. To move backward in Help, press Bksp. To exit Help: 1. Scroll through to the beginning or end of the help prompts. 2. At the first prompt, press #. Or, at the last prompt, press Enter. The screen returns to the prompt shown prior to entering Help mode.
Exiting Prompting Configuration Mode You have two ways to exit Prompting Configuration mode: •
To exit and update the parameters, press Esc or scan:
*$-* *$-*
•
To exit without updating the parameters, press Ctrl Z or scan:
*-.* *-.*
Prompting Configuration Mode Example In this example, the reader is not connected to a CRT, and you want to disable Code 93. The reader has the large character 1x20 display. Follow these steps: 1. Scan the Prompting Configuration label. Enter Prompting Configuration
*$+$+* *$+$+*
The 9560 displays this prompt: <?>HELP <CR>START
2. Press Enter. The 9560 displays this prompt:
6-14