The original document is the PDF (1.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 9560
Page 101
Data Communications and Operating Options
5
Katakana Characters in Roman Alphabetical Order Key
Key
Alt+key
Alt+key
A
Ku-Ten a
“
3 del b
Q ,
B
HajimeKakko b
!
4
R c
S
C
OwariKakko c
K
5
P d
T U V W X Y Z ! @ 3 $ % ^
D
Doku-Ten d
>
6
Daku-Ten
E
Chyu-Ten e
$
7
F
< » ¼ . ¾ À Á ½ ¿ / f
%
8 g
?
9
L N ~ h
:
i
= j
;
k
.
l
_ m
& n
¥ o
(
P
Cho-on Fugue p
)
& * ( ) _ + | { } :
Q
A B C D E F G H I J q
‘ r
* s
< t
/ u
- v
M w
# x
R y
+ z
" a e f g h i j k l m n o p q r s t u v w x y z
G H I J K L M N O
R S T U V W X Y Z
5-27
Page 102
9560 Transaction Manager User’s Manual
Katakana Characters in Japanese Alphabetical Order Normal Katakana Characters
~
|
)
%
Z
U
P
K
F
A
Alt+9 w t o j e
Alt+5
Alt+c
V
Q
{
^
!
V
Q
L
G
B x p k f a
Alt+7
W
R
}
_
&
@
W
,
M
H
C y u q l g b
Alt+v
X
S
:
*
3
X
S
N
I
D z r m h c
Alt+8
Y
T
<
"
+
(
$
Y
T
O
J
E
F
Alt+z v s n i d
Alt+4
Z
U
> Alt+x
Lowercase Katakana Characters
Á
»
L
G
¼ H
/
½
.
O
M
I
¾ J
5-28
¿
À
N
K
Page 103
Data Communications and Operating Options
5
Special Katakana Characters in Japanese Alphabetical Order Cho-on
Ku-ten
Alt+U
A
Chu-ten
Hajime-kakko
Alt+L
B
¥
Owari-Kakko
Alt+N
C
Daku-Ten
Doku-ten
Alt+6
D Chyu-ten E
Ro-maji Mode Character Table The following table shows the Ro-maji spelling for each Katakana character that appears on the display. When the reader is configured for Ro-maji mode, type in the Roman letters underneath the desired character and the Katakana character appears on the display. Hint: As you type in Ro-maji, Katakana characters appear on your display. If you see Roman letters appear, and you did not press the function key to toggle to the US-ASCII character set, you made a mistake. To correct your mistake, press Backspace to erase all the Roman letters and retype your message.
Ro-maji Spelling for Katakana Characters Normal Katakana Characters
~
|
)
%
Z
U
P
K
F
A wa ra ya ma ha na ta sa ka a
{
^
!
V
Q
L
G
B ri mi hi ni ti/chi si/shi ki i
}
_
&
@
W
,
M
H
C ru yu mu hu/fu nu tu/tsu su ku u
:
*
3
X
S
N
I
D re me he ne te se ke e
$
Y
T
O
J
E ho no to so ko o
>
"
+ nn ro yo mo
5-29
Page 104
9560 Transaction Manager User’s Manual
Ro-maji Spelling for Katakana Characters (continued) Daku On Characters
°
-
¦
¡ ba da za ga
±
¬
§
¢ bi di zi/ji gi
²
¨
« bu du zu gu
³
®
©
¤ be de ze ge
´
¯
ª
¥ bo do zo go
Handaku On Characters
Lowercase Katakana Characters
µ
Á
» pa xya xa
¶
¼ pi xi
·
½
/
.
pu xyu xtu/xtsu xu
¸
¾ pe xe
¹
¿
À po xyo xo
5-30
Page 105
Data Communications and Operating Options
5
9560 Operating Modes and Command Types The 9560 has three basic operating modes: •
Data Entry mode, which includes Accumulate and Full ASCII modes
•
Configuration mode
•
IRL Editor mode
Data Entry mode By default, the reader is in Data Entry mode, waiting to receive data or commands from a bar code label, the keypad, or the host. You scan a label or send a command to change modes. For example, if you want to set several reader parameters, you would enter Prompting Configuration and make changes.
Use configuration mode to define the general operation of the scanner, such as bar codes recognized. For more information, see Chapter 6, “Configuring the 9560.” Configuration mode
Use the IRL editor to create and edit IRL programs. For more information, see Chapter 9, “Interactive Reader Language.”
IRL Editor mode
Accumulate Mode Accumulate mode is a part of Data Entry mode that you use to build longer data blocks to send to the host. The reader stores both multiple-read and regular labels in the data buffer until you tell the reader to send the information to the host. After scanning the Enter Accumulate label and a regular label, the reader does the following: 1. sounds one low beep, 2. adds the label information to the data buffer, 3. holds the data until you send the command to transmit. The reader transmits the buffer contents only after you scan the Enter label, the Exit Accumulate label, or the Transmit (No Clear) label. See Chapter 8, “Data Entry Commands,” for information on the Accumulate mode commands.
5-31
Page 106
9560 Transaction Manager User’s Manual
Full ASCII Mode Full ASCII mode is a part of Data Entry mode that you use to enter or transmit ASCII control characters or lowercase characters as data. When the reader is in Full ASCII mode, it decodes alphanumeric characters as ASCII characters. For example: If the Reader Is
And You Scan
The Reader Records
In Full ASCII
*$M* the ASCII control character
CR (0D Hex) Out of Full ASCII
*$M*
2 alphanumeric characters,
$ and M In or Out
*$* and *M* of Full ASCII
$ and M
2 alphanumeric characters,
See Chapter 8 “Data Entry Commands” for information on the Full ASCII mode commands.
Command Types The 9560 recognizes two types of commands: configuration commands and data entry commands. Configuration commands Set the reader operating parameters, bar codes, communication protocol, and protocol characters. These settings are saved in memory, even if the reader’s power is removed. When you scan the Default Configuration label, the reader operating parameters return to the factory default settings.
For the complete definition of all Configuration commands, see Chapter 7, “Configuration Commands.” Data Entry commands Cause the reader to perform specific functions, such as transmit data or sound beeps. When you scan a Default Configuration label, changes you made with Data Entry commands are not saved.
For the complete definition of all Data Entry commands, see Chapter 8, “Data Entry Commands.”
5-32
Page 107
code39 helconital nugget
6 Configuring the 9560
A F
B
K
G
C
L
H
D
M
I
P U
Q V
R W
E N
J
S
O
X
T Y
C ap s $ 7
/ , Z
4
8
1
5
9
2
6
0
3
B ks p
S pa ce
In
. E n te r te rm
F 1 F 2 F 3 F 4 F 5
F 6 F 7 F 8 F 9
9 F10 5 6 0 ec
Page 108
nugget code39 helconital
Page 109
Configuring the 9560
6
This chapter explains how to configure the 9560 to work in your system.
Specifying Configuration Parameters Before you use the 9560 with your system, you must specify these configuration parameters: • Bar code symbologies • Reader operating parameters • Communications protocol You may be able to use the default configuration settings. Compare the default settings listed in the tables in this section with the settings required by your system. If your system can operate with the default settings, then skip this chapter and proceed to Chapter 8, “Data Entry Commands.” Use any of the following five methods to specify the configuration settings. Bar code command label configuration You can quickly configure the 9560 for one or more particular parameters by scanning the appropriate bar code label. For a specific bar code command, see Chapter 7, “Configuration Commands.” Batch configuration In Batch configuration, you can configure each reader in the system identically. You print a bar code “menu” of the common parameters, and then scan this into each reader. See “Using Batch Configuration,” later in this chapter. Default configuration Scan the Default Configuration label or download the .+ command from the host to use the factory default settings. You can scan this label any time except when the 9560 is in Prompting Configuration mode. Default Configuration
*.+* *.+*
You can download configuration commands from the host computer. See “Using Downloading Commands,” later in this chapter.
Download configuration
The 9560 displays the configuration commands on the reader display or terminal screen and prompts you for all the options for each command. See “Using Prompting Configuration,” later in this chapter.
Prompting configuration
6-3
Page 110
9560 Transaction Manager User’s Manual
Note: You do not need to reconfigure the 9560 after a power failure. The 9560 saves your selected parameters in nonvolatile memory. Note: The 9560 keypad does not contain a Ctrl key. To enter a command requiring the Ctrl key, scan a bar code or use a 1700 keyboard or a terminal keyboard.
Bar Code Configuration Settings Parameter
Options
Codabar
Disable No start/stop
ABC ABCD stop/start
Standard DC1-DC4 stop/start
CODE 11
Disable
1 check digit
2 check digits
CODE 39
Disable Transmit ck digit
No check digit Not transmit ck digit
Check digit
Code 93
Enable
Disable
Code 128
Disable
Standard
Full ASCII
Enable
Disable
I 2/5
Disable
Specified even length
Variable length
Case code
2 of 5
Disable
3 bar start/stop
2 bar start/stop
Specified length
UPC/EAN
All versions enabled
UPC A/EAN-13 enable
EAN-8 enable EAN-8 disable
Supplementals enable
UPC E enable UPC E disable
UPC A/EAN-13 disable
UPC A only
Supplementals disable
Default settings are in bold text.
6-4
Concatenated
HBIC
UCC128 only