Page 1 of 9181/9183 900MHz RF Equipment User's Manual

Manual · Intermec

9181/9183 900MHz RF Equipment User's Manual

Manual26 pagesPDF 218 KB

User's manual for the Intermec 9181 Base Radio Unit and 9183 Radio Repeater for 900 MHz RF data collection networks.

Download the PDF218 KB

Covers · 1 model

The models it covers

Summary

What is in it

Intermec's user's manual for its 900 MHz RF equipment: the 9181 Base Radio Unit, which links a Model 200 Controller or other Intermec controller to the RF data collection network, and the 9183 Radio Repeater, which extends radio coverage. For each unit it explains the components and status LEDs, mounting to drywall, wood and metal, and troubleshooting; for the BRU it also covers connecting and terminating cables to the Model 200 and 9180 controllers, and for the repeater, setting its DIP switches.

Its parts

  1. Before You Begin
  2. 1 9181 Base Radio Unit
  3. 2 9183 Radio Repeater

From the manual · read page by page

Key facts from this manual

Each line names its page in the PDF.

Intermec's 1997 user's manual (P/N 066163-001) for the 9181 Base Radio Unit and the 9183 Radio Repeater, parts of its 900 MHz RF data collection network. It explains mounting both units, cabling the 9181 to a Model 200 or 9180 controller, setting the 9183's channel switches, and reading the self-test lights.

Device
9181: base radio unit linking a Model 200 Controller or another Intermec network controller to the 900 MHz RF network p. 11
Connections
9181: power cord plus one serial link to the controller; antenna on a front-panel connector, directly or through coax p. 11
Controller cable
9181: Belden 89688 cable (Intermec P/N 583326) or equivalent p. 14
Cable kit
9181: Intermec P/N 055003, connectors and pins for the controller end and the BRU end p. 14
Cable distance
9181: up to 2,000 feet (650 meters) from the controller at 64 Kbps p. 14
Controllers
9181: Model 200 Controller (2-port or 4-port RF controller card) or 9180 controller (DNLN 1 or DNLN 2) p. 14, 15
Status LEDs
9181: Power, Radio Rx/Tx and RFNC Rx/Tx; 9183: Power, RX and TX p. 12, 22
BRU connector pins
9181: A RX+, B RX-, J TX+, K TX-; other pins not used p. 16
9180 DNLN pins
RXD on pins 8 and 9, TXD on 4 and 6, shield ground 1 and 3, circuit ground 7, +5 VDC on 5 p. 15
Self-test faults
9181: ROM, both Rx/Tx LEDs blink rapidly; RAM, Radio blinks and RFNC off; CPU, Radio off and RFNC blinks p. 17
RF channels
9183: 924, 921, 918, 915, 912, 909 or 906 MHz, set by switches 1 to 3 of SW1 p. 24
Repeat counts
9183: up to seven per signal; no more than three recommended p. 21
Repeater faults
9183: ROM test, RX and TX blink; RAM test, RX blinks and TX off; Internal RAM, RX off and TX blinks p. 26
Mounting
Within 4 feet of a power outlet; wood at least 1/2 inch thick with 5/16-inch screws; metal at least 14 gauge steel p. 12, 13, 25

What this manual walks you through

  • Mounting the 9181 base radio unit with the antenna pointing down p. 12, 13
  • Connecting the 9181 to a Model 200 Controller p. 14
  • Connecting the 9181 to a 9180 controller p. 15
  • Terminating the cable at the BRU and controller ends p. 16, 17
  • Reading the status LEDs p. 12, 22
  • Troubleshooting 9181 self-test failures p. 17
  • Setting the 9183 repeater DIP switches p. 23, 24, 25
  • Installing the 9183 repeater p. 25
  • Troubleshooting 9183 self-test failures p. 26

Good to know

  • Do not fit a DB-9 or other connector at the BRU end and run a short cable to the BRU; it gives poor performance. p. 16
  • Plastic anchors in drywall will not safely hold either unit; mount on a ceiling joist. p. 12, 25
  • Front panel torque matters: too little lets water in, too much damages the gasket. p. 24
  • Do not overtighten the shield band, or it cuts through the shield and the internal wires. p. 16
  • Self-test rapid blinking differs from the once-a-second blink of controller status packets; disconnect the BRU to tell them apart. p. 17

Questions this manual answers

What cable connects an Intermec 9181 to the controller?

Belden 89688 cable (Intermec P/N 583326) or equivalent, with cable kit P/N 055003; the run can be up to 2,000 feet at 64 Kbps. p. 14

How do I set the RF channel on a 9183 repeater?

Open the rear panel and set switches 1, 2 and 3 of SW1; the channels run from 906 to 924 MHz. p. 24

How many repeaters can a signal pass through?

Up to seven repeat counts are allowed, but the manual recommends no more than three because they slow data. p. 21

Why are the LEDs on my 9181 blinking?

Rapid blinking after power up means a ROM, RAM or CPU self-test failed; a blink once a second is normal controller traffic. p. 17

Does the 9183 repeater need a data cable?

No, its only cable is the power cord. p. 25

The whole text · 3 parts

Read the manual here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 91-9
  2. Pages 10 to 1810-18
  3. Pages 19 to 2619-26

The file

Revision and size

RevisionP/N 066163-001, 1997
PublisherIntermec Corporation
Pages26
PDF218 KB
TextText from the PDF itself.

The first pages · 3 of 26

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 26
Page 2
Page 2of 26
Page 3
Page 3of 26

More documents · 2

For the same models