Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 2 of 3

9181/9183 900MHz RF Equipment User's Manual, pages 10 to 18

Pages 10 to 18 of 26

The original document is the PDF (218 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Intermec 9181

Page 10

.

Page 11

9181 Base Radio Unit

1

Learning About the 9181 Base Radio Unit The 9181 Base Radio Unit (BRU) links the Model 200 Controller or another Intermec network controller to the Intermec 900 MHz RF data collection network. It broadcasts information from the controller to the Intermec RF devices and receives RF signals from the devices, passing the information back to the controller. Note: The only physical connection to the BRU, other than the power cord, is to a serial port on the controller. The antenna attaches to a connector on the front panel, either directly or through a coax cable.

Understanding the BRU Components This figure shows the components for the BRU. The communications port connector, status LEDs, antenna connector, and power cord are all on the front panel. 9181 BRU Components

Ba se

Ra dio PO

WE

R

Power cord

RF

R Rxadio /Tx

NC

AN

TE

RF Rx NC /Tx

NN

91

83

A

Status LEDs Antenna connector

918XU.001

1-3

Page 12

9181 and 9183 User’s Manual

Understanding the BRU Status LEDs The front panel of the base radio unit contains three LEDs that continuously display the status of the unit. During power up and self tests, all LEDs are on and then they turn off. If all tests pass, the LEDs will show the status described in this table. LED

Description

Power

Indicates the BRU is receiving power.

Radio Rx/Tx

Lights when BRU is receiving or transmitting a packet through the radio.

RFNC Rx/Tx

Lights when the BRU is receiving or transmitting a packet of information with the controller.

Note: When the 9181 is connected to a controller, the controller sends out a packet every second. This causes the Radio Rx/Tx and the RFNC Rx/Tx LEDs to blink once a second.

Installing the BRU To install the BRU, make sure that you use cables that are appropriate for the distance between the BRU and the controller. Then, use one of these procedures.

Mounting to Drywall Surfaces If mounting the unit to drywall (sheetrock), make sure it is mounted on a ceiling joist. Plastic anchors in drywall will not safely support the BRU.

Mounting to Wood Surfaces If mounting the unit to wood, the minimum thickness must be 0.5 inch (12.7 mm). Use 5/16-inch sheetmetal or wood screws.

1-4

Page 13

9181 Base Radio Unit

1

Mounting to Metal Surfaces If mounting the unit to a metal surface, the minimum unreinforced thickness must be 14 gauge (steel). To install the BRU 1. Locate the BRU within 4 feet (1.22 m) of a power outlet. 2. Bolt the BRU to the rafters so the antenna points down. The front panel LEDs should be visible from the ground. 3. You may want to review the section “Terminating the Cable at the BRU” carefully before you continue. Route the cable between the BRU and the controller and secure with plastic tie wraps or cable clamps. At the end of the cable near the BRU, create a 7inch drip loop to prevent water from leaking into the connector. Leave a similar loop in the power cord. 4. Attach the antenna to the BRU so it points down. Make sure it is at the lowest point of the ceiling and reaches below all beams, pipes, and ducts. Installing the 9181 BRU

Mounting screws

A N T E N N A

R

F

N

C

B as e

R ad io

P O W E R

R R a x/T dio x

R R FN x/T C x

91 83

Tiewrap

Water drip loops 918XU.002

1-5

Page 14

9181 and 9183 User’s Manual

Connecting the BRU to the Model 200 Controller To connect the BRU and the Model 200 Controller, you need to know if you have a 2-port or 4-port RF controller card in the controller. You will also need: •

Intermec cable kit (Intermec P/N 055003) or equivalent. Each kit contains two sets of connectors and pins: one for the controller and one for the BRU.

•

Belden 89688 cable (Intermec P/N 583326) or equivalent. The BRU and the controller may be separated by as much as 2,000 feet (650 meters) with a data rate of 64 Kbps.

To connect the BRU to the Model 200 Controller 1. Refer to “Terminating the Cable at the BRU” and “Terminating the Cable at the Controller End” later in this chapter for important information on terminating the cable before you connect the BRU and controller. 2. Connect the 9-socket end of the cable to the controller. •

If you have a 2-port RF controller card, connect one end of the Belden cable to one of the ports on the card.

•

If you have a 4-port card, Intermec provides you with a 4-port interface cable. Insert the controller end of the interface cable into the port on the RF controller card. Connect one end of the Belden cable to one of the downline connectors (DNLN 1, DNLN 2, DNLN 3, or DNLN 4).

3. Connect the other end of the cable to the BRU.

Connecting the BRU to the 9180 Controller To connect the BRU and the 9180 Network Controller, you need:

1-6

•

Intermec cable kit (Intermec P/N 055003) or equivalent. Each kit contains two sets of connectors and pins: one for the controller and one for the BRU.

•

Belden 89688 cable (Intermec P/N 583326) or equivalent. The BRU and the controller may be separated by as much as 2,000 feet (650 meters) with a data rate of 64 Kbps.

Page 15

9181 Base Radio Unit

1

To connect the BRU to the 9180 controller 1. Refer to “Terminating the Cable at the BRU” and “Terminating the Cable at the Controller End” later in this chapter for important information on terminating the cable before you connect the BRU and controller. 2. Connect the 9-socket end of the cable to one of the downline connectors (DNLN 1 or DNLN 2) on the controller. Refer to the table on the next page for DNLN port pin assignments. 3. Connect the other end of the cable to the BRU. Refer to the table on the next page for BRU pin assignments. DNLN Port Pin Assignments Pin No.

Function

8

RXD Input Circuit A (Differential input pair for receive data)

9

RXD Input Circuit B

4

TXD Output Circuit A (Differential output pair for transmit data)

6

TXD Output Circuit B

1

Shield Ground

3

Shield Ground

7

Circuit Ground

5

+5 VDC

BRU to Network Controller Connection Network Controller

BRU

Rx+ A Rx- B

4 6

Tx+ Tx-

9 8

Rx+ Rx-

Shield Tx- K Tx+ J

918XU.003

1-7

Page 16

9181 and 9183 User’s Manual

BRU Pin Assignments

A

H G

B C

J

K F

D E

Pin

Function

A

RX+

B

RX-

J

TX+

K

TX-

All other open pins are not used.

Terminating the Cable at the BRU The conductor and cable shield for the BRU must be terminated properly. Do not terminate the cable with any other connector than the ones that Intermec recommends. Placing a DB-9 or any other connector at the BRU end of the cable and then running a short cable to the BRU connector is not acceptable and will result in poor performance. Note: If you are attaching the connector to the cable before running the cable along the ceiling, make sure the cable will not have to pass through any small holes or other obstructions that will not let the connector through. You may want to test or Ohm out the cable for shorts before connecting it to either the BRU or the controller.

Connectors That Require a Banding Tool Follow the instructions that come with the cable carefully. The bands that secure the cable shield to the BRU connector backshell is a standard shell (0.25 inch) and can be tightened with any automotive CV joint boot banding tool. Note: Do not overtighten the band or it will cut through both the shield and the internal wires. Once the shield band is installed, make sure you heat the waterproof heat shrink in place to protect the back of the connector.

Clamp-Type Connectors Note: If you are using the clamp-type BRU connector, assemble the BRU connector kit onto the end of the cable. Make sure the cable shield is properly terminated in the connector backshell.

1-8

Page 17

9181 Base Radio Unit

1

Terminating the Cable at the Controller End Once the BRU is mounted and the cable is routed and secured to the controller, size up the cable and provide plenty of extra cable length before you cut the cable. Cut the cable and terminate it with the 9-pin D shell connector from the kit. Note: It is very important that you connect the cable shield to the backshell of the connector.

Troubleshooting the BRU During power up and the self tests, all LEDs are on. If any of the self tests fail, the LEDs will blink. The LED blink patterns are listed in this table. Fault

Radio Rx/Tx LED

RFNC Rx/Tx LED

ROM Test rapid blinking rapid blinking

RAM Test rapid blinking off

CPU Test off rapid blinking

Note: Do not confuse the rapid blinking in the self tests with the blinking (every second) that occurs when the controller sends out status packets. To verify which blinking is occurring, disconnect the BRU from the controller.

1-9

Page 18

This page is a scan with no text; see it in the PDF.