A four-page Getting Started Guide (P/N 066120-002, 1998) for the Intermec 9180 Network Controller, the unit that links an Intermec 900 MHz RF data collection system to the host computer. It explains where the controller fits, what is needed to install it, how to cable it to the host, console and power, and lists its physical, electrical and interface specifications.

Device
Network controller between the host and an Intermec 900 MHz RF data collection system p. 2
Host interface
EIA RS-232 or RS-422, 300 bps to 19.2 KBps, ASCII asynchronous p. 4
Downline ports
Two RS-422 ports, DB9, 64 KBps, HDLC, 64 devices p. 4
Back panel
POWER, DNLN 2, HOST, DNLN 1 and CONSOLE connections, RESET/RUN switch p. 3
AC power supplies
120 V P/N 054182; 100 V P/N 054183; 230 V P/N 054184 p. 4
Host cable reach
RS-232 null modem up to 50 ft; RS-422 to 4000 ft; modem beyond p. 3
Console settings
Full duplex, 9600 bps, even parity, 7 data bits, 2 stop bits p. 3
Dimensions
11.1 in x 7.5 in x 2.5 in (28.2 cm x 19.1 cm x 6.3 cm) p. 4
Weight
6 lb p. 4
Operating temperature
32º to 122ºF (0º to 50ºC) p. 4
Storage temperature
-40º to 158ºF (-40º to 70ºC) p. 4
Humidity
10% to 90% non-condensing p. 4
Compatibility
Addressing and protocol compatible with the 9154 p. 4
Full manual
RF System/9180 Controller User's Manual, P/N 054292 p. 4

What this manual walks you through

  • How the 9180 fits in an Intermec 900 MHz RF system p. 2
  • Choosing a place for the controller p. 3
  • Connecting the controller to the host directly or by modem p. 3
  • Connecting the configuration console p. 3
  • Connecting power and running the power-on self-test p. 3
  • Setting up the console to configure the controller p. 3

Good to know

  • Leave at least 6 inches behind the back panel and keep the controller away from dirt, debris and liquids. p. 3
  • Make sure the controller is off before plugging in the power supply. p. 3
  • Beyond 4000 feet the host link needs a modem and an RS-232 modem cable. p. 3
  • Detailed setup and troubleshooting are in the separate RF System/9180 Controller User's Manual. p. 3

Questions this manual answers

What does the Intermec 9180 do?

It handles all communications between the host computer and the Intermec 900 MHz RF data collection network, in both directions. p. 2

What power supply does the Intermec 9180 use?

An Intermec AC supply: P/N 054182 for 120 V, 054183 for 100 V, or 054184 for 230 V, all 50/60 Hz. p. 4

What console settings does the 9180 controller need?

Full duplex, 9600 bps, even parity, 7 data bits and 2 stop bits. p. 3

How far can the 9180 be from the host?

Up to 50 feet with an RS-232 null modem cable, up to 4000 feet with RS-422, and farther with modems. p. 3

How many devices can a 9180 network controller support?

Its two RS-422 downline ports support 64 devices. p. 4

The file

Size and text

Pages4
PDF133 KB
TextText from the PDF itself.

Every page · 4

Read it here

Each page as it is printed, and its words beside it, so a phone can search and copy them.

Page 1 of Intermec 9180 Guide

The text of page 1, from the PDF itself

Getting Started Guide

9180 Network Controller P/N 066120-002

Page 2 of Intermec 9180 Guide

The text of page 2, from the PDF itself

Congratulations on Selecting Intermec to help you meet your data collection needs. You have chosen a world leader in the data collection industry.

collection network. It takes the data that is collected through the RF channels and sends it to the host computer. The 9180 Network Controller is also responsible for transmitting data from the host to the data collection devices. After it has been installed, the controller can be configured to meet your system’s specific layout requirements.

How the 9180 Network Controller Fits in a Data Collection System The Intermec 900 MHz RF data collection system is comprised of several devices that work together to compile all the data you collect and send to the host computer.

® FoT91twkC1trollererow Plt auFt osH m ro t os HoonFTLNN1orDLN2NDNem roLN2FoNTDLNNDm ro809180G.001

The 9180 Network Controller can handle all communications between the host computer and the Intermec 900 MHz radio frequency (RF) data

When installed and configured, the system works automatically and requires no assistance by an operator. The only devices that require operation are the scanners and readers used to collect the data. The rest of the RF system works as a transparent link between the data collection devices and the host computer.

,, 9183 Repeater

J2050 Vehicle Mount Unit

J2010 Reader and Scanner

SHIPPINGFINISHED GOODSPrinter with 9189RECEIVING9181 Base Radio UnitPRODUCTION

9189 with fixed reader and wands 9181 Base Radio Unit 9180 Network Controller

Supervisory ConsoleOFFICEHost Computer9180G.002

Page 3 of Intermec 9180 Guide

The text of page 3, from the PDF itself

Getting Started

2.

Place the controller on a clean stable surface that is close to an AC power outlet or surge protector. Also place the controller in an area that is protected from dirt, debris, and liquids. Position the controller so that the front panel is visible, and there is at least 6 inches (15.24 cm) behind the back panel.

To connect to the host For distances of up to 50 feet (15 meters), plug the 25-pin D-style connector prongs of the RS-232 null modem cable into the connection marked HOST on the controller back panel. Plug the other end into the host computer.

To install the 9180 Network Controller you need

a console to configure the controller.

a standard RS-232 cable for connecting the console to the controller.

Note: For distances between 50 feet (15 meters) and 4000 feet (1220 meters) use an RS-422 connection.

an Intermec DC power supply (see “Basic Electrical and Environmental Specifications” for part numbers).

an RS-232 cross-over modem bypass (null modem) cable to connect the controller directly to the host, or an RS-422 cable if the host is 50 feet (15 meters) to 4000 feet (1220 meters) from the controller. Note: For distances greater that 4000 feet (1220 meters), use a modem and a modem cable assembly that supports an RS-232 interface.

To connect with a modem Plug the 25-pin Dstyle connector prongs of the RS-232 cable into the connection marked HOST on the controller back panel. Plug the other end into a modem. Connect a modem to the host. The two modems must be connected with an acoustic coupler or a direct telephone line. 3.

Connect one end of the standard RS-232 cable to the connection marked CONSOLE on the controller back panel. Plug the other end into the console, or the modem.

4.

Turn on the controller by pressing the power switch on the back panel to the ON ( I) position. The light emitting diodes (LEDs) on the front panel will light, indicating the controller is performing a self-test. When the self-test is finished, the Power LED will remain on.

After you have placed the controller and have the power supply, console, and cables, you are ready to install the controller. 1.

Connect the controller to the host directly or with a modem.

9180Network ControllertterwulFatosH1221osHLNNLNNPoToD LNLNNNDDomFromToToomFrFrD

Make sure the controller is OFF. Connect the power supply four-pin connector into the connection marked POWER on the controller back panel. Connect the other end into the AC power outlet or surge protector.

9180G.004

Do not turn on the controller. 5. Power Supply

Configure your console so you can use it with the controller. Refer to the RF System/9180 Controller User’s Manual for more information. The console must be set for:

RESET RUNIS1POWERDNLN 2HOSTDNLN 1CONSOLE6.O9180G.003

full duplex operation 9600 bps even parity 7 data bits and 2 stop bits

Configure your controller using the console. Refer to the RF System/9180 Controller User’s Manual for more information.

Page 4 of Intermec 9180 Guide

The text of page 4, from the PDF itself

Physical Specifications Dimensions

11.1 in x 7.5 in x 2.5 in (28.2 cm x 19.1 cm x 6.3 cm)

Weight

6 lb (13.2 kg)

Basic Electrical and Environmental Specifications Power supply

AC power supplies available: 120 V 50/60 Hz (P/N 054182) 100 V 50/60 Hz (P/N 054183) 230 V 50/60 Hz (P/N 054184)

Electrical ratingP P P R 10 V, 500 mAOperating temperature

32º to 122ºF (0º to 50ºC)

Storage temperature

-40º to 158ºF (-40º to 70ºC)

Relative humidity

10% to 90% relative non-condensing

Other Specifications Host Interface

EIA RS-232 or RS-422 Data rate: 300 bps to 19.2 KBps ASCII asynchronous protocol Odd, even, mark, space parity 7 or 8 data bits One or two stops bits Xon/Xoff handshake Optional LRC for enhanced data integrity checking Addressing and protocol compatible with 9154

Downline Communications

Two ports DB9 connectors RS-422 Data rate: 64 KBps NRZI Protocol: ISO Standard HDLC Devices supports: 64

Where to Find More Information The RF System/9180 Controller User’s Manual (P/N 054292) contains all of the information necessary to install, configure, operate, and troubleshoot the controller. For information on ordering a manual, contact your local Intermec sales representative.