The text of a manual · part 5 of 33
9154 Line Controller System Manual, pages 41 to 50
Pages 41 to 50 of 330
The original document is the PDF (7.7 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 9154
Page 41
Controller Features
Controller Polled Device Interface Features The controller's polled device interface, with its Multi-Drop port, has the following features that support a wide range of user device layouts.
* The Multi-Drop channel is capable of supporting up to 32 readers and printers. You can connect up to ten satellite wand stations to each reader in a daisy chain stretching up to 150 feet in length. Using a drop line configuration, the ten satellite wand stations can extend over a distance of up to 500 feet.
* The controller is upwardly compatible with the INTERMEC 9161 02 Multi- Drop Concentrator. The controller can work with over eight different models of INTERMEC readers and printers in a CrossBar network, including the following:
Devices: Comments:
Readers:
INTERMEC 9440 (Requires 9440 Communication dock)
INTERMEC 9510
INTERMEC 9511
INTERMEC 9512
INTERMEC 9540
INTERMEC 9550
Printers:
INTERMEC 863X-Series INTERMEC 864X-Series
. High speed data transmission between the controller and the polled devices can occur at up to 19200 baud.
© 1987 INTERMEC Corporation Page 2-11
Page 42
INTRODUCTION TO THE 9154
A SAMPLE 9154 SYSTEM
The 9154 Controller is a controller for the CrossBar system a group of INTERMEC components designed to work within existing data processing environments. CrossBar components can be used together to satisfy a wide variety of data collection and data processing needs. CrossBar networks are composed of three types of components:
1. AController or Port Concentrator 2. Various Bar Code Printers and Bar Code Readers 3. Input Devices
The controller or concentrator controls the data traffic between polled devices (readers and printers) and the host computer. Bar code printers print bar code labels. Bar code readers decode data from bar code labels and transmit it to the controller or port concentrator. Input devices scan the bar code labels and pass that information to the reader to be interpreted. Input devices include laser scanners, keyboards, satellite wand stations, and wands.
Page 2-12 © 1987 INTERMEC Corporation
Page 43
A Sample 9154 System
Figure 2-5 illustrates an example of a 9154 Controller-based CrossBar network used as a manufacturing control system. Moving outward from the controller along the Multi-Drop cable, and then clockwise around the system, the components are as follows.
* Aprinter is used in the Receiving Department to mark incoming parts with bar code labels. A reader with a wand is used to track incoming parts inventory.
° In stores, a reader equipped with a laser scanner and keyboard is used to track inventory of both parts and finished products.
* On the shop floor, assembly line workers use satellite wand stations to record what job was done, who performed the job, and when it was performed. Six satellite stations are connected to the reader.
* Areader with a slot scanner for reading badges is used by employees to record their starting and ending times.
* The host computer in the office is connected directly to the 9154 Controller using an appropriate hardware interface. The controller provides real time data from the devices to the host.
* The INTERMEC-supplied power supply transforms AC power to DC power levels required by the controller.
. A Supervisory CRT, used to configure the original system, is reconnected to troubleshoot problems or change operating parameters as needed.
. The 9154 Controller monitors all the communication between the host and the five devices. The entire system of polled devices is connected by Multi- Drop cabling. Using the controller as an interface, the host can work with the four readers and the printer using only one of its communication ports.
© 1987 INTERMEC Corporation Page 2-13
Page 44
INTRODUCTION TO THE 9154
Satellite Wand Stations
Reader «( \, Slot NAS _<Scanner
Reader
Reader, __ - \_ Scanner ~ Reader Wand ae Ss Keyboard pa Printer “ Host Z Computer oo 9154 Multi-Drop Power Supervisory Line Controller Supply
CRT
Figure 2-5 A Typical 9154 Controller Configuration
Page 2-14 © 1987 INTERMEC Corporation
Page 45
SECTION 3
DESIGNING A 9154 SYSTEM
DESIGN CONSIDERATIONS
PLANNING THE PHYSICAL LAYOUT Installation Plan Installation Guidelines Laying Multi-Drop Cabling Test System
SELECTING A COMMUNICATION INTERFACE BETWEEN THE HOST AND 9154
Available Interfaces
Comparing RS-232 and RS-422/485
Data Line Considerations
GROUNDING CONSIDERATIONS Communication Interfaces and Grounding Grounding Conductor Making a Good Ground Connection Grounding Long Data Lines
LIGHTNING PROTECTION
THROUGHPUT AND RESPONSE TIME ANALYSIS
Introduction Calculating the Response Time Deriving Cycle Times
CONFIGURATION PREPARATION
Data Communication Considerations Configuration Parameters
© 1987 INTERMEC Corporation
Page 3-1
Page 46
DESIGNING A 9154 SYSTEM
DESIGN CONSIDERATIONS
This section contains general instructions for planning the installation of a CrossBar system based on the 9154 Controller. It addresses the physical installation and some aspects of the configuration of the controller firmware. Good initial planning prevents future operational problems. A system not meeting the guidelines and requirements outlined in this section is not guaranteed to work properly.
PLANNING THE PHYSICAL LAYOUT
Installation Plan
To plan your system installation, determine which locations will be serviced, how many stations are required, and what other equipment will be interfaced with the 9154 Controller. Itis a good idea to review your requirements with a staff member of your company’s facility maintenance department.
As part of the planning process, include a scale floor plan layout such as the one shown in Figure 3-1. List the required equipment in the layout and show the locations where equipment is to be installed. After making a scale layout, check the layout against the physical installation requirements listed in the next section, "Installation Guidelines,” to ensure the system will work correctly.
Figure 3-1 illustrates the scale layout for the sample controller-based system shown in Figure 2-5. Note the distances marked on the layout. They can be used to check the total length of the Multi-Drop line, and to estimate the location of the Multi-Drop devices to ensure that the drop segments are kept to a maximum of 30 feet in length.
Many trade-offs in cable length and interfaces occur in designing a system. For example, to minimize the length of the main trunk cable, the controller may be located closer to the devices. A shorter main trunk line, however, may result in a longer cable connection between the controller and the host computer. A greater length of cable is susceptible to interference introduced by electrical machinery. To reduce interference, an RS-422/485 interface may be required rather than the RS-232 interface.
Page 3-2 © 1987 INTERMEC Corporation
Page 47
Planning the Physical Layout
Receiving L Main Office CEPI ISTE Feet Wand | a 3 ae 8 aren: en Stores 33 i ot 1 i) 300 Feet Engineering 200 y ts Feet ; K 1 t- - i : Me Liaw TARA RAXRANAGOODOAAASAAA RA 100 (Potential Future Production Expansion) fe T Feet ty} Lunch 1} Room Slot Pa Scanner 2 & Ny * ] J { 1 T | at 200 Feet > 250 Feet 2 Main Trunk Line, System Component to Accessary WE CDrop Segments (30 ft. Max) {This tine not to scale) @2ZZa Host to Controller Interface Satelliie Wand Station Figure 3-1
Installation Floor Plan
© 1987 INTERMEC Corporation Page 3-3
Page 48
DESIGNING A 9154 SYSTEM
Installation Guidelines Plan the layout of the system with the following guidelines in mind.
The Multi-Drop line connecting the devices must meet the following requirements. Figure 3-2 illustrates these requirements.
* The maximum length of the main trunk cable should not exceed 2000 feet.
* The maximum drop length from the main trunk cable to a device should not exceed 30 feet.
+ The drop sites must be at least two feet apart.
* The polled devices connected to any one controller should all be located in the same building.
Multi- Drop Controller | 2000 Ft. Max. 4 "ly ca | t 30 Ft. Max. Device Device Device } 2 Ft. Min. Figure 3-2
Minimum and Maximum Cable Lengths
Page 3-4 © 1987 INTERMEC Corporation
Page 49
Planning the Physical Layout
The distance between the host and the controller is one of the factors effecting the choice of communication interface to use. The distance can be up to 4000 feet with an RS-422/485 interface and even longer lengths may be used witha RS-232 interface operating into a modem.
CAUTION
Interconnecting cables that run too close to other electrical equipment or using cables of extreme length can cause internal physical damage or hinder the performance of your equipment. . The layout of the installed cable should be engineered to ensure that the noise and ground potential values are kept within specification.
To minimize electrical interference, avoid areas where cables and equipment will be located near other large electrical power equipment (for example, large motors, welders, motor controllers, and switching gear).
The building in which the system is to be installed must be provide a good earth ground to which the controller can be connected.
If the quality of the AC power source is questionable, surge protection is advised.
A maximum of 32 polled devices may be hooked up to the Multi-Drop line. However, since ten satellite wand stations can be connected to one reader, and each reader counts as one device, you can connect a much larger array of bar code equipment to the controller. In general, a device is something that can be reading all the time. For example, 10 satellite wand stations can be connected in a daisy chain to a reader, but at any given moment only one wand station may be scanning bar code.
© 1987 INTERMEC Corporation Page 3-5
Page 50
DESIGNING A 9154 SYSTEM
Satelllte Wand Stations: The satellite wand stations themselves can be arranged in two configurations according to your needs. Figure 3-3 illustrates both the daisy chain and drop line layouts. For more detailed information about connecting satellite wand stations to your reader, see the appropriate INTERMEC reader manual.
Daisy Chain: If the satellite wand stations are strung together in a daisy chain, the cable length from the reader to the last satellite station can be a maximum distance of 150 feet. You can place up to ten satellite wand stations can be placed anywhere within the 150 feet of length. Figure 3-3 a) illustrates the daisy chain configuration.
Drop Line: If a drop line is used, connect the 10 satellite wand stations to drop boxes which are placed in the drop line. Figure 3-3 b) illustrates the drop line configuration. You must meet the following layout for a drop line:
* The cable distance from the reader to the first drop box can be a maximum of 10 feet. A satellite wand station may not be connected to the first drop box.
*, The entire length of the drop line, from the first drop box to the last drop box, may not exceed 500 feet.
* The maximum cable length from a drop box to a satellite wand station is 50 feet.
. Do not daisy chain together satellite wand stations off a drop box.
Available INTERMEC cables for making satellite wand station interconnections are listed in the Satellite Wand Station section of your reader manual.
Page 3-6 © 1987 INTERMEC Corporation