SECTION 2

INTRODUCTION TO THE 9154

INTRODUCTION

LOCATING CONTROLLER COMPONENTS Front Panel Rear Panel Status and Power Lights

CONTROLLER FEATURES Controller Internal Features Controller External Features Controller Supervisory CRT Interface Features Controller Host Interface Features Controller Polled Device Interface Features

A SAMPLE 9154 SYSTEM

© 1987 INTERMEC Corporation

Page 2-1

Page 32 read from a scan by OCR; it may hold reading errors

INTRODUCTION TO THE 9154

INTRODUCTION

The 9154 Multi-Drop Line Controller manages the flow of information between a host computer and up to 32 INTERMEC Bar Code Readers and Printers. The controller's buffering capability allows the host computer to perform other tasks in addition to serving the data collection network. Figure 2-1 shows the controller unit as it comes from INTERMEC, with its packaging removed.

Using a Supervisory CRT, you can configure the controller to operate with a wide variety of host computer requirements for communication protocol, including unsolicited or solicited data transmission. You can change data communication protocol parameter values from the default values as needed to satisfy user requirements.

The controller supports RS-232 and RS-422/RS-485 Communication standards as hardware interfaces to the host. 20 mA Current Loop standard can be supported with an external adapter.

Up to thirty-two readers or printers may be connected to the controller using a single 4-wire RS-485 Multi-Drop main trunk cable connected to the controller's Multi-Drop port. Over eight different models of INTERMEC readers and printers are supported.

Although the controller is built to withstand constant use in an industrial environment and requires little maintenance, it can be damaged by improper use. To avoid problems, read this manual carefully.

Page 2-2 © 1987 INTERMEC Corporation

Page 33 read from a scan by OCR; it may hold reading errors

introduction

9154 Muti-Drop Line Controller o non \Z

Rubber Feet

9154 Muti-Drop Line Controller System Manual

Figure 2-1 9154 Muiti-Drop Line Controller

© 1987 INTERMEC Corporation Page 2-3

Page 34 read from a scan by OCR; it may hold reading errors

INTRODUCTION TO THE 9154

LOCATING CONTROLLER COMPONENTS

Both the front and rear panel of the controller contain connectors for connecting other system components. The front panel also contains one power and four status indicator lights. For the location of individual controls, see Figure 2-2 for the front pane! and 2-3 for the rear panel. Information on using the controls and connectors to perform specific tasks appears as required throughout this manual.

Front Panel

In order from left to right, the front panel contains the five lights, the Power pushbutton, and the CRT connector. The front panel is illustrated in Figure 2-2. Mounting holes are located on the sides of the controller.

Status and Power Lights: The lights show the condition of various system functions and also highlight system problems by blinking. An explanation of how to use each of the status lights appears in the next sub-section, "Status Lights."

CAUTION

Before disconnecting the power supply from the controller, ensure the controller Power pushbutton is in the off position. If the power supply is disconnected before the controller is turned off, the controller's firmware may not function correctly on power-up.

Power Pushbutton: Pushing the Power pushbutton in and out turns the controller on and off by controlling the power received from the power supply. When the Power Pushbutton is out, the controller will not operate. Once in operation, never remove the controller power supply before its power has been turned off. The internal battery only provides backup power for memory and the real time clock operation.

CRT Connector (9-Pin, "D" Style, sub-miniature socket): The CRT connection connects the controller to the Supervisory CRT with an RS-232 interface. You will need adapter cable which makes the 9-Pin to 25-Pin connection, such as INTERMEC Part No. 041789S. Section 4, “Installing Hardware,” explains how to connect a Supervisory CRT to the controller.

Page 2-4 © 1987 INTERMEC Corporation

Page 35 read from a scan by OCR; it may hold reading errors

Locating Controller Components

Mounting Holes: Using the mounting holes, the controller can be mounted to a wall or other flat surface, either horizontal, vertical, or somewhere in between. The mounting holes are on either side of the controller and extend completely through the controller body. The two mounting holes do not have to be used. Section 4, "Installing Hardware,” demonstrates how to mount the controller.

Mounting Holes a (not shown) oo

2 A % S s eo ¢ [ S a < oe oe lomenemene) 9154 (MM)INTERMEC, _/ OC roo) O

Z AT

“ a na \ i) Lights Power Pushbutton (5 places) Figure 2-2 Front Panel Rear Panel

In order from left to right, the rear panel contains connectors to the power supply, host, and polled devices, as well as the grounding stud. The rear panel is illustrated in Figure 2-3.

Power Supply Connector: The power supply connector connects the INTERMEC-supplied power supply to the controller. The controller does not directly connect to an AC power source. Section 4, “Installing Hardware,” explains how to connect the power supply to the controller and a usable AC power source.

© 1987 INTERMEC Corporation Page 2-5

Page 36 read from a scan by OCR; it may hold reading errors

INTRODUCTION TO THE 9154

Host Connector (25-Pin, "D" Style, sub-minlature socket): The host connector connects the host computer to the controller with an RS-232 or RS- 422/RS-485 interface. Current Loop is supported using an external adapter and the RS-232 interface. INTERMEC Technical Centers (ITCs) can provide a list of suggested manufacturers and ordering instructions for Current Loop adapters. Section 3, "Designing a 9154 System," explains how to choose an appropriate hardware interface for your work environment, and Section 4, "Installing Hardware,” gives guidelines for installing the interfaces.

Polled Device Connector (9-Pin, "D" Style, sub-minlature socket): The device connector connects the 4-wire RS-485 Multi-Drop cabling from the polled devices to the controller. One main trunk cable is supported by the controller, but up to 32 devices can be connected to the main trunk cable. Section 3, “Designing a 9154 System,” explains how to design a Multi-Drop cabling system, and Section 4, "Installing Hardware,” explains how to install one.

Grounding Stud: The grounding stud is used to connect the controller toa building or earth ground. The controller must be connected to a ground for proper operation. Section 3, “Designing a 9154 System,” explains how to select the best ground, and Section 4, “Installing Hardware," explains how to connect a ground cable to the controller.

fad fim | Olbez==d peux @ va

I va \ T 7 1 ‘ ) Power Supply Host Polled Device Ground Stud Connector Connector Connector Figure 2-3 Rear Panel

Page 2-6 © 1987 INTERMEC Corporation

Page 37 read from a scan by OCR; it may hold reading errors

Locating Controller Components

Status and Power Lights

The five lights on the front panel indicate various system conditions. There are four status lights and one power light. Section 10, “Troubleshooting,” explains how the status lights, when blinking, can also be used for diagnosing controller problems. Figure 2-4 shows the front panel location of each light. A description of each light follows.

In order from left to right:

Lights: Turns on when:

1 Poll (Status) A polled device and the controller are communicating. 2 Host (Status) The host and the controller are communicating.

3 Fault (Status) A communication error is detected in the host or polled device protocol. The Fault light will blink if the power up RAM test fails.

4 Config (Status) The user has entered a Supervisory CRT screen that allows configuration parameters to be modified. The Config light will blink if a EEPROM hardware failure occurs.

5 Power Controller power is on.

All four status lights (Poll, Host, Fault, and Config) blink if the ROM test fails.

N SS e & ao of & - ca x 9154 (Ii) INTERMEC J © © e 2X

HH

Figure 2-4 Status and Power Lights

© 1987 INTERMEC Corporation Page 2-7

Page 38 read from a scan by OCR; it may hold reading errors

INTRODUCTION TO THE 9154

CONTROLLER FEATURES

An overview of the 9154 Controller features follows. In later sections of the manual, as the information is required for using the controller effectively, each feature is explained in greater detail.

Controller Internal Features The controller has the following internal features which help it function smoothly and self-sufficiently.

+, Aninternal battery protects data in the controller's memory for up to two weeks in case of power failure. If a protected firmware routine is executing when power is interrupted, that routine will be completed when power is restored.

+ Buffering capability allows polled device data to be stored while the host computer is performing other processing.

* Transient Voltage Suppression on the Supervisory CRT, Multi-Drop, and host hardware interfaces protect against electrostatic discharge (ESD).

+ Aconfigurable real time clock can append the time to data coming into the controller from the polled devices or broadcast the time to the readers.

Controller Externai Features The controller has several external features that help make it easy to operate.

+, Status lights indicate system conditions and assist in troubleshooting system problems.

* Agrounding stud allows connection of the controller to an earth ground to provide convenient system grounding and lightning protection.

Page 2-8 © 1987 INTERMEC Corporation

Page 39 read from a scan by OCR; it may hold reading errors

Controller Features

Controller Supervisory CRT Interface Features The use of a Supervisory CRT simplifies configuration of the controller.

¢ A9Q-Pin connector on the front of the controller allows attachment of a Supervisory CRT terminal. Once the controller system is set up, the Supervisory CRT can be used to view the system's operation, or it can be removed and used elsewhere.

. Automatic baud rate detection sequence for the Supervisory CRT port simplifies interfacing various CRT types to the controller. The following standard CRT types are supported:

IBM 3101 DEC VT100 ADM 3/5 Televideo ADM 31/32/42 Hazeltine

The controller's CRT interface parameters can be easily configured to support other CRTs.

¢ The Supervisory CRT interface facilitates troubleshooting system problems. Supervisory CRT screens can display error messages as well as data in the polled device buffer, and can also be used to send messages to polled devices.

© 1987 INTERMEC Corporation Page 2-9

Page 40 read from a scan by OCR; it may hold reading errors

INTRODUCTION TO THE 9154

Controller Host Interface Features

The controller's host interface has the following features that make the controller adaptable to a wide range of host communication protocols. The controller's host interface can be customized to meet specific host requirements.

. Host-to-controller communication protocol can be modified from the default parameter values. Both solicited or Unsolicited protocol are selectable.

* High speed data transmission can occur at up to 19200 baud between the host computer and the controller.

* True XON/XOFF handshake capability for both receiving and transmitting data to the host allow unsolicited communication protocols to be used effectively.

* The controller can be connected with the host computer using an RS-232, RS-422/485, or an optional 20 mA Current Loop adapter connected to the RS-232 interface.

* A transparency check can be enabled on the controller-to- host communication data link so that communication protocol parameters may be sent as data.

+, Device specific polling by the host is supported to simplify requesting the status of INTERMEC printers.

Page 2-10 © 1987 INTERMEC Corporation