The text of a manual · part 3 of 33
9154 Line Controller System Manual, pages 21 to 30
Pages 21 to 30 of 330
The original document is the PDF (7.7 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 9154
Page 21
Related INTERMEC Manuals
RELATED INTERMEC MANUALS
The following manuals offer additional information about equipment that may be used in a 9154 controller-based system.
INTERMEC Manual: Part No.: Systems Manuals 9510 Online Reader System Manual 046854 9511 Online Reader System Manual * 047247 9512 Online Reader System Manual * 046156 9540 Bar Code Terminal System Manual * 048538 9550 Transaction Manager System Manual * 048539 8630-Series Operator's Guide, 046065 Installation Guide, and Programmer's Manual 8640-Series Thermal TransferPrinter System Manual 048834 Quick Reference Cards 9510 Online Reader Quick Reference Card 046853 951 1/9512 Online Reader Quick Reference Card 047463 1700 Digital Keyboard Quick Reference Card 047234 9191 Satellite Wand Station Quick Reference Card 047249 9540/9550 Online Reader Quick Reference Card 048540 Other Manuals Data Communications Manual 044737 IRL 2.1 Programming Reference Manual 048609
* includes: 1700 Digital Keyboard Guide and 9191 Digital Satellite Wand Station Guide
WARRANTY INFORMATION
INTERMEC Corporation offers its customers a choice of warranty options. To receive a copy of the standard warranty provision for this product, contact your local INTERMEC sales organization and request the information. Refer to the Authorized Service Locations list which was shipped with this manual for the address and telephone number.
© 1987 INTERMEC Corporation Page 1-5
Page 22
HOW TO USE THIS MANUAL
Upon request, customers who are residents of the USA and Puerto Rico will receive the INTERMEC Corporation Supplemental Statement of Warranty (Form 603876); customers residing outside the USA will receive a Statement of Warranty prepared and supported by their local INTERMEC distributor.
Please complete and return the Reader Reply Card which is located at the front of this manual. No postage is necessary if it is mailed within the United States. SAFETY SUMMARY
General Safety Guidelines
Only trained and authorized technicians or operators should work on energized electrical equipment. Improper repair methods could result In Injury or death.
The safety of persons handling or operating INTERMEC equipment is extremely important. Warning and cautions necessary for safe handling and operation are included within the various sections of this manual. You should read all warnings and cautions in this manual before handling or operating INTERMEC equipment.
Page 1-6 © 1987 INTERMEC Corporation
Page 23
Safety Summary
Do Not Repair Or Adjust Alone: Do not under any circumstance repair or adjust energized equipment alone. The immediate presence of someone capable of rendering aid is essential for operator safety.
First Ald: An injury, no matter how slight, should never be neglected. Always obtain first aid or medical attention immediately after incurring an injury.
Resuscitation: Persons working on or near high voltage should be familiar with approved industrial first aid methods. If someone is injured and stops breathing, initiate resuscitation immediately. A delay could result in the victim's death.
Energized Equipment: Energized electrical equipment is dangerous. Electrical shock from energized equipment can cause death. Never work on energized equipment unless authorized to do so by a responsible authority. If emergency work on energized equipment is authorized, be sure that it is accomplished in strict compliance with approved safety regulations.
Warning and Cautions
The specific warnings and cautions printed on the following pages appear within the text elsewhere in this manual. They are reprinted here for emphasis. Each warning and caution is referenced to the section in which it appears.
A WARNING is an operating procedure, practice, condition, or statement which, if not strictly observed, could result in injury or death to persons handling the equipment.
A CAUTION is an operating procedure, practice, condition, or statement which, if not strictly observed, could result in damage to or destruction of equipment, or subsequent loss of equipment effectiveness.
Section 1
WARNING
Only trained and authorized techniclans or operators should work on energized electrical equipment. Improper repair methods could result in Injury or death.
© 1987 INTERMEC Corporation Page 1-7
Page 24
HOW TO USE THIS MANUAL
Section 2
CAUTION
Before disconnecting the power supply from the controller, ensure the controller Power pushbutton Is in the off position. If the power supply Is disconnected before the controller Is turned off, the controller's firmware may not function correctly on power-up.
Section 3
CAUTION
Interconnecting cables that run too close to other electrical equipment or cables of extreme length can cause internal physical damage or hinder performance of your equipment. The lay out of the Installed cable should be engineered to ensure that the nolse and ground potential values are kept within specification. WARNING
The grounding conductor should not be attached to steam or hot water pipes, lightning-rod conductors, or pipe or rod service electrodes that are not part of a multiground neutral power circult.
Page 1-8 © 1987 INTERMEC Corporation
Page 25
Safety Summary
Section 4
CAUTION
The system must be grounded and the controller grounding stud must be connected to an earth ground. Failure to connect the unit to an earth ground could result in loss of system data integrity and the possible physical deterioration of the controller due to ESD or lightning.
WARNING
Before connecting the power supply, ensure that the controller Power pushbutton Is In the off position. Failure to do so could cause injury due to electrical shock.
CAUTION
Before disconnecting the power supply from the controller, ensure the controller Power pushbutton Is in the off position. If the power supply Is disconnected before the controller is turned off, the controller's firmware may not function correctly on power-up.
CAUTION
The signal levels between the controller and both the host computer and Supervisory CRT must be as specified within supported EIA standard. If other signal levels are used, the controller, Supervisory CRT, and host computer could be damaged.
© 1987 INTERMEC Corporation Page 1-9
Page 26
HOW TO USE THIS MANUAL
Section 5
CAUTION
In most cases, two communication parameters can not be defined as the same value or communication will be Impossible. For example, If the SOM and EOM characters are BOTH defined as ETX (03H), the host and the controller will be unable to communicate. The controller will not know whether or not ETX indicates the beginning or the end of a message.
Section 6
CAUTION
All devices must be set to the same baud rate as the controller. If all the devices are not operating at the same baud rate, data communication problems will result.
Section 8
CAUTION
In most cases, two communication parameters can not be defined as the same value or communication will be impossible. For example, if the SOM and EOM characters are BOTH defined as ETX (03H), the host and the controller will be unable to communicate.
Page 1-10 © 1987 INTERMEC Corporation
Page 27
Safety Summary
Section 9
CAUTION
Do not interrupt power to the controller for more than two weeks, lf the controller contains valuable data. A power interrupt exceeding two weeks may result in the loss of data as the NiCad battery runs down and becomes unable to protect data.
CAUTION
After the controller's battery is depleted to the extent it is unable to back up RAM, charge the battery before interrupting AC power. If the battery is not allowed to recharge, data stored in RAM could be lost during an extended power interrupt.
Section 11
Only trained and authorized technicians or operators should work on energized electrical equipment. Improper repair methods could result in Injury or death.
CAUTION
Before disconnecting the power supply from the controller, ensure the controller Power pushbutton is in the off position. If the power supply is disconnected before the controller is turned off, the controller's firmware may not function correctly on power-up.
© 1987 INTERMEC Corporation Page 1-11
Page 28
HOW TO USE THIS MANUAL
WARNING
Do not incinerate, crush, or puncture batteries. The electrolyte contained in NiCad batteries is composed of caustic materials that are harmful to eyes and skin.
WARNING
Do not short-circuit the battery. Burns may result. Short circults can occur if a battery Is placed on a metal shelf, if metal tools are used, or if the battery is placed in a pocket containing coins or keys.
Page 1-12 © 1987 INTERMEC Corporation
Page 29
Documentation Conventions
DOCUMENTATION CONVENTIONS
Terminology Throughout this manual, the 9154 Multi-Drop Line Controller is referred to as the controller or the 9154.
The word device, when used alone, refers to a data collection device (reader or printer), not an input device (wand, satellite wand station, or laser scanner) that scans bar code information into the data collection device.
The words device and polled device are used interchangeably. All devices mentioned in this manual support INTERMEC Multi-Drop protocol, so they may also be called Multi-Drop Devices.
The word plug refers to the male part of a connector, and the work socket refers to the female part of a connector.
All the plugs and sockets referred to in this manual, both 9-Pin and 25-Pin, are "D"-Style, sub-miniature connectors. Thus, 9-Pin socket, and 9-Pin, “D*-Style, sub-miniature socket are used interchangeably.
Keystroke Definitions
Letters enclosed in square brackets { ] refer to a single key on the terminal keyboard. When two or more sets of square brackets are used, it means to press those keys simultaneously. For example, [CNTL] [P] means to press the control key and the letter "P“ key at the same time. If there is a comma between the keys, press the keys individually in serial fashion. For example, [1], [0] means to press the number key "1", and then press the number key "0." Keyboard entries that require more than one keystroke may be enclose in quotation marks. For example, "4800" means to press the [4], [8], [0], [0] keys in sequence.
© 1987 INTERMEC Corporation Page 1-13
Page 30
HOW TO USE THIS MANUAL
Depending on the type of keyboard, the name of certain keys may differ. This manual refers to the following keys:
Key: What It Means:
{CR] RETURN. This key may be labeled RETURN, RET, ENTER, or an ALT 191.
[ESC] ESCAPE. This key may be labeled ESC, Esc, or Escape.
[CNTL] CONTROL. This key may be labeled CTRL, ctrl, or Control.
[BKSP] Backspace. This key may be labeled Backspace, BACKSPACE, or an ALT 191.
[DEL] Delete. This key may be labeled, Rub, Del, or del.
Page 1-14 © 1987 INTERMEC Corporation