The text of a manual · part 31 of 33
9154 Line Controller System Manual, pages 301 to 310
Pages 301 to 310 of 330
The original document is the PDF (7.7 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 9154
Page 301
GLOSSARY
End of Program Block/Continue Character (EOP) -- Sent by the host after a block of IRL program statements to tell the reader that another block of IRL statements is coming.
End of Record Character (EOR) -- Sent at the end of a message record.
FCC -- Federal Communications Commission. Maintains government regulations regarding communication and electronic equipment.
FIFO -- First In, First Out. The first record stored in a buffer is the first record to be processed.
Hardware -- Physical equipment, such as mechanical, magnetic, electrical, or electronic devices, as opposed to the computer program or method of use.
Interference, See Electromagnetic Noise.
LED, Light emitting diode. A semiconductor that produces light at a wavelength determined by its chemical composition. This light source is often used in bar code readers.
LRC -- Longitudinal Redundancy Check; a check that is the exclusive OR of all the rest of the bits in the message. In 9154 Controller operation it starts at the second bit of the header, if no header is used at the second character of the SOM, or at a minimum at the first character of the message.
Main Trunk Cable, The Multi-Drop cable extending from the 9-Pin polled device connector on the rear of the controller.
Modem -- MOdulator/DEModulator; a device for conversion of one form of a signal to another that is suitable for transmission over communication circuits, typically from digital to analog and then from analog to digital.
Multi-Drop Protocol -- Used when connecting multiple readers to a INTERMEC 9154 Controller or a 9161A Option 02 Multi-Drop Concentrator. Muiti-Drop protocol is similar to Polling Mode D; however, in Multi-Drop, each device on the line is assigned a unique POL and SEL character. Multi-Drop operates only at 2400 baud or higher, and its data communication protocol can’t be modified.
© 1987 INTERMEC Corporation Page G-3
Page 302
GLOSSARY
Negative Acknowledge Character (NEG) -- Indicates a negative acknowledgement to a message.
Ontine -- An operation in which peripheral devices are connected directly to the processing unit.
Parity -- A system for encoding binary characters with an odd or even number of binary "1" bits. Parity is not related to whether the original characters are odd or even, but rather to how an individual character is made to have an odd or even number of "1" bits with the addition of one more bit (1 or 0). When Even parity is used, characters having an odd number of binary ones in their structure have a "1" bit added to make the number of "1" bits even. Characters whose binary representation already has an even number of "1" bits have a "0" bit added so that the number of "1" bits remains even. For the purpose of data processing and data communication, parity is used to provide a self-checking feature in bar codes and other transmission techniques.
Poll Character (POL), Sent by the host to request reader data. For Multi- Drop protocol, a unique character should be defined for each reader on a data line.
Preamble -- Predefined data that is automatically appended to the beginning of transmitted data. Commonly used to identify which peripheral the host is receiving information from.
Program Acknowledgement Character (PAK) -- Sent by the reader in response to a good program.
Program Statement Separator Character (PSS) -- Separates individual IRL program statements from one another in a block of IRL program statements. PSS must not be defined same as EOM.
RAM, Random Access Memory; contents can be altered any time. Information can be written or read anywhere within the storage device in the same amount of time, regardless of where the information is stored.
Reader -- A device used for machine reading of bar codes; typically consists of a scanner, a decoder, and a data communications interface.
ROM, Read Only Memory; normally contents of this type of electronic memory are read, but can’t be altered. See EEPROM.
Page G-4 © 1987 INTERMEC Corporation
Page 303
GLOSSARY
RS-232 - - An industry standard (EIA) for a 25-Pin hardware interface used between computers and various types of peripheral equipment to allow communication.
RS-422/485, An industry standard (EIA) for a 9-Pin hardware interface between electronic equipment which is used to allow the equipment to communicate.
Select Character (SEL) -- Sent by the host to request if the reader can accept data. For Multi-Drop protocol, a unique character should be defined for each reader on a data line.
Start of Message Character (SOM) -- The first character in messages sent to or received from the host.
Transient Voltage Suppressors -- An electronic circuit that protects a line from voltage surges. Used on the 9154 Controller host computer and Supervisory CRT interfaces.
UART, Universal Asynchronous Receiver/Transmitter. Modem.
XON/XOFF Character -- Allows XON/XOFF flow control.
© 1987 INTERMEC Corporation Page G-5
Page 304
Page 305
APPENDIXES
APPENDIX A: SPECIFICATIONS APPENDIX B: DEFAULT EEPROM SETTINGS APPENDIX C: ASCIi CONTROL CHARACTERS
APPENDIX D: FULL ASCII CHART
© 1987 INTERMEC Corporation Page A-1
Page 306
APPENDIXES
APPENDIX A: SPECIFICATIONS
PHYSICAL CHARACTERISTICS
The controller package consists of an injection molded plastic top and bottom housing. The bottom housing supports the electronics. The package is spill resistant but not waterproof. The interior of the housing is sprayed with conductive paint for shielding.
DIMENSIONS
Height: 1.4 in (3.5 cm) Width: 6.5 in (16.5 cm) Length: 7.5 in (19.1 cm)
HARDWARE INTERFACES
Host Port
EIA RS-232 EIA RS-422/485
Page A-2 © 1987 INTERMEC Corporation
Page 307
Appendix A
Multi-Drop Port
EIA 4-wire RS-485
Supervisory CRT Port
EIA RS-232
ENVIRONMENTAL
The controller will operate in ambient temperatures from 0° C to +50° C and can be stored from -10° C to +60° C. The controller will operate from 10% to 90% relative humidity (non-condensing).
OPERATOR FEEDBACK
The controller has four status lights and one power light which are visible through a window on the front panel. The power light turns on when the controller receives +5 volts.
SAFETY STANDARDS MET
. UL 478 5th Ed.
° CSA C22.2 #154-M1983
. VDE 0806/08.81
. VDE 0871/06.78
* FCC Docket 10780 Part 15, sub par. J
© 1987 INTERMEC Corporation Page A-3
Page 308
APPENDIXES
Page A-4 ©1987 INTERMEC Corporation
Page 309
Appendix B
APPENDIX B: DEFAULT EEPROM SETTINGS
Parameter: Default:
Supervisory CRT
Clear Screen Sequence <SUB>
Cursor Position Sequence <ESC>=RC
Host Line Parameters
Line Speed 9600 Parity E Data Bits 7 Stop Bits 1
Multi-Drop Line Parameters
Line Speed 9600 Address p
Supervisory CRT Line Parameters
Line Speed 9600 Parity E Data Bits 7 Stop Bits 2
To Host Transmission Parameters
# Records Per Bik 1
Record Separator <CR>
Header
SOM <STX>
EOM <ETX>
RES <STX> Z <CR> AFF <STX> Y <CR> NEG <STX> Z <CR> Error Message SOM <STX>
Error Message EOM <ETX> Transparency Check N
Data Wait Mode N
©1987 INTERMEC Corporation
Possible Values:
Up to 6 ASCII characters
Up to 8 ASCII characters
19200,9600,4800,2400,1200, 600,300,110
E=Even, O=Odd, N=None 7or8 tore
19200,9600,4800,2400 m,n, 0, p
19200,9600,4800,2400,1200, 600,300,110 E=Even, O=Odd, N=None
7or8 defaulted
0 to 99
Up to § ASCII characters Up to 5 ASCII characters Up to 5 ASCII characters Up to 5 ASCII characters Up to 5 ASCII characters Up to 5 ASCIl characters Up to 5 ASCII characters Up to 5 ASCII characters Up to 5 ASCII characters Y for Yes or N for No
Y for Yes or N for No
Page B-1
Page 310
APPENDIXES
Parameter: Default: Possible Values:
From Host Transmission Parameters
POL <ENQ> Up to 2 ASCil characters SEL <BEL> Up to 2 ASCII characters AFF <ACK> Up to 2 ASCII characters NEG <NAK> Up to 2 ASCII characters DLE <DLE> Up to 2 ASCII characters SOM <STX> Up to 2 ASCII characters EOM <ETX> Up to 2 ASCII characters Record Separator <CR> Up to 2 ASCII characters Delay (x 10 ms) 1 0 to 99 Timeout (x 1 sec) 60 0 to 60 Xon / Xoff Enable N YorN LRC Enable N YorN
Real Time Clock Parameters
Date 87.01.01 Year.Month.Day Time 00.00 Hour.Month
Time Append
Enable Time Append N Y for Yes or N for No Interval (x 1 minute) 1 0 to 99
Record Day Rollover N Y for Yes or N for No
Time Broadcast
Enable Time Broadcast N Y for Yes or N for No Interval (x 1 minute) 1 0 to 99
Preamble <HT> up to 5 ASCII characters Postamble, up to 5 ASCil characters Display Format 24 12 or 24
Include YY/MM/DD N Y for Yes or N for No
Page B-2 ©1987 INTERMEC Corporation