Troubleshooting with the Supervisory CRT
The procedure outlined below is easier and quicker than compiling a list of all the individual device addresses. |t would be necessary to go to each device, put it into the required mode, and determine its address. Even then you still would not know if the controller was configured to use those addresses.
1. Call up the Select Polled Devices screen from the Master Menu by entering [6], [CR]. The Select Polled Devices screen will be displayed as shown in Figure 10-3.
Select Polled Devices
TIME
Connected
Connected
VOZRHPAGHITUAAMVAWDY HAMA MAM OAM MH OM UPBWNHKHFON KK ECCHUNDO AA MMMM MAAN OM
Press CNTL-T For Listing of Task Options
\ A
Figure 10-3 Select Polled Devices
© 1987 INTERMEC Corporation Page 10-15
Page 292
TROUBLESHOOTING
2. Look in the status column, to the right of the device addresses, and see which addresses have an E for enabled.
3. Inspect the devices to ensure that they are all on.
4. Check the column to the right of the status column on the Select Polled Devices screen. Any device address with “Connected” in it is being used. For example, address W in Figure 10-3 is being polled by the controller, and is able to respond.
5. Check that the “Connected” devices equal the number of devices that are physically connected and turned on.
If the number of devices is larger than the number of "Connected" addresses on the Select Polled Devices screen, either there is a problem with one or more devices not communicating with the controller, or two devices may have the same address.
6. If some addresses are enabled, but "Connected" is not displayed, these addresses may be used by new devices.
If you need more enabled addresses, press [CR] until the cursor is across from the address, and then enter [E], followed by [CR] to enable an address. Repeat as necessary.
7. Exit the Select Polled Devices screen using one of the two following procedures:
a. Enter [CNTL] [7] to write the device address settings to the RAM copy of the configuration parameters, re- initialize the controller and return to the Master Menu.
b. Enter [ESC] to save the device address settings to the EEPROM copy of the configuration parameters, re- initialize the controller and return to the Master Menu.
Page 10-16 © 1987 INTERMEC Corporation
Page 293
SECTION 11
MAINTENANCE
MAINTENANCE SUMMARY SAFETY PRECAUTIONS Energized Equipment Resuscitation Do Not Repair or Adjust Alone INSPECTION CLEANING
DISCONNECTING OR POWERING DOWN THE CONTROLLER
POWER SUPPLY MAINTENANCE
INTERNAL BATTERY
© 1987 INTERMEC Corporation
Page 11-1
Page 294
MAINTENANCE
MAINTENANCE SUMMARY
The 9154 Controller requires no maintenance during normal operation. For years of trouble-free use, follow the guidelines and procedures listed below:
SAFETY PRECAUTIONS
Only trained and authorized technicians or operators should work on energized electrical equipment. Improper repair methods could result in injury or death.
Energized Equipment
Energized electrical equipment is dangerous. Electrical shock from energized equipment can cause death. Never work on energized equipment unless authorized to do so by a responsible authority. If emergency work on energized equipment is authorized, be sure that it is accomplished in strict compliance with approved safety regulations.
Resuscitation
Persons working on or near high voltage should be familiar with approved industrial first aid methods. If someone is injured and stops breathing, initiate resuscitation immediately. A delay could result in the victim's death.
Do Not Repair or Adjust Alone
Do not under any circumstances repair or adjust energized equipment alone. The immediate presence of someone capable of rendering aid is essential for operator safety.
Page 11-2 © 1987 INTERMEC Corporation
Page 295
Safety Precautions
INSPECTION
Occasionally, a visual inspection of the controller and the rest of the system should be performed to ensure that the system is intact and that hazardous changes in the work environment have not occurred.
1. Check that the controller is properly connected to an earth ground. The connection to the controller grounding stud should be tight and free of corrosion. The connection wire should be tightly connected to an earth ground, such as the building ground, power service conduit, or grounded metal structure.
2. Inspect the work environment for conditions that would interfere with the proper function of the controller. Large electric motors, welders, and switching equipment may alter the original conditions under which the data communication interface was chosen. See Section 3, “Designing a 9154 System,” and Section 4, "Installing Hardware," for information on how to choose the correct data communication interface for your environment.
3. Check that the controller is properly mounted. Ensure that the mounting location is safe and free from the potential for water or other liquids coming in contact with the controller system.
4. Check all data communication connections. Ensure that they are properly connected and free of corrosion.
© 1987 INTERMEC Corporation Page 11-3
Page 296
MAINTENANCE
CLEANING
Wipe dust and dirt from the controller using a soft cloth and non-abrasive cleaner. The controller is spill-proof, but not water-proof. Do not allow cleaning fluid or any other liquid to get into the interior of the controller.
DISCONNECTING OR POWERING DOWN THE CONTROLLER
CAUTION
Before disconnecting the power supply from the controller, ensure the controller Power pushbutton Is In the off position. If the power supply is disconnected before the controller is turned off, the controller's firmware may not function correctly on power-up.
To avoid damaging the equipment, observe the following procedure when disconnecting power to the controller:
1. Disconnect, disable with the Supervisory CRT, or turn off all polled devices. 2. Turn off the controller. 3. Disconnect the power supply from the rear of the controller.
Page 11-4 © 1987 INTERMEC Corporation
Page 297
Power Supply
POWER SUPPLY
The power supply is not a repairable unit. If the power supply is damaged, it must be removed and replaced with a new power supply. Contact your local INTERMEC service representative.
When replacing a power supply, check that the new power supply is the correct one for the controller and the available power source. See Section 4, "Installing Hardware,” for instructions on determining the proper power supply.
If you are experiencing recurrent problems with the power supply, the best way to protect the power supply is to ensure that the power source is noise-free, free of voltage surges, and of the proper voltage and frequency. Electronic devices are available to remove voltage surges from power sources.
MAINTENANCE
During normal operation, you should never have to open the controller. If damage to the EEPROM or other internal components is suspected, contact your local INTERMEC service representative. The four status lights indicate that the following internal damage may exist.
. If the fault light blinks every half second, the RAM is defective. . If the configuration light blinks every half second, the EEPROM is defective.
. If all four status lights blink every half second when the controller is powered up, the ROM is defective.
For additional information on determining if internal damage has occurred, see Section 10, “Troubleshooting.”
© 1987 INTERMEC Corporation Page 11-5
Page 298
MAINTENANCE
INTERNAL BATTERY
Do not Inclnerate, crush, or puncture batteries. The electrolyte contained In NiCad batteries is composed of caustic materlals that are harmful to eyes and skin.
Do not short-circult the battery. Burns may result. Short circults can occur If a battery is placed on a metal shelf, if metal tools are used, or if the battery Is placed in a pocket containing coins or keys.
The controller contains a NiCad battery that backs up the RAM during power-down. As necessary, the controller charges the battery. The battery requires no maintenance and should last the life-time of the controller.
Page 11-6 © 1987 INTERMEC Corporation
Page 299
GLOSSARY
Affirmative Acknowledgement Character (AFF) -- Indicates an affirmative acknowledgement to a message.
Alphanumeric -- The character set which contains letters, numbers and usually other characters such as punctuation marks.
ASCII -- The character set and code described in American National Standard Code for Information Interchange, ANSI X3.4- 1977. Each ASCIl character is encoded with 7-bits (8-bits including parity check). The ASCII character set is used for information interchange between data processing systems, communication systems and associated equipment. The ASCII set consists of both control and printing characters.
Bar Code Reader -- A device used to read a bar code symbol.
Bit -- An abbreviation for “binary digit". A single element (0 or 1) in a binary number.
Byte -- A combination of bits in a predetermined pattern, designed to representa digit or alphanumeric character.
Character - 1. A single group of bars and spaces which represent an individual number, letter, punctuation mark, or other symbol. 2. A graphic shape representing a letter, numeral, or symbol. 3. A letter, digit, or other symbol that is used as part of the organization, control, or representation of data.
CMOS - A type of integrated circuit with a low power drain. Chemically, a combination of PMOS and NMOS.
Compile and Run IRL Program Character (RUN) -- Sent by the host to define the end of a downloaded program and tell the reader to run the program (if no errors found).
Computer Response Required Mode (CRRM) -- When enabled, the reader requires a response from the computer before the reader will accept more data. The message must be transmitted using the protocol currently in effect. The protocol characters only, with no data, are sufficient.
© 1987 INTERMEC Corporation Page G-1
Page 300
GLOSSARY
Configuration -- The selected parameters to determine the operation of the controller.
CrossBar -- An INTERMEC designation for a group of Bar Code equipment that works together to provide flexible networks that meet customer requirements. Devices that readily communicate with each other.
Digital -- Pertaining to data in the form of digits. In signals, digital refers to a signal which assumes one of a predetermined set of values, such as 0 or 1, as opposed to a signal which may assume any value over a continuing range of values, such as an analog signal.
Drop Cable -- The cable that extends from a Multi-Drop main trunk cable to the polled device. A length of 30 feet is allowed with INTERMEC Part No. 047653. Maximum length of 20 feet with a customer-supplied cable.
Drop Site -- The location on a Multi-Drop main trunk cable where a drop cable is connected.
EEPROM - Electrically Erasable Programmable Read Only Memory.
In the 9154 Controller, the integrated circuit (IC) where configuration parameters are stored when they are permanently saved.
EIA -- Electrical Institute of America. Maintains industry standards for electrical and electronic equipment, for example RS-232. Specifications can be ordered from EIA Engineering Department, Standards Sales Office, 2001 Eye St. NW, Washington, DC, 20006.
Electromagnetic Noise -- Sometimes called Electromagnetic Interference (EMI), the undesirable electromagnetic phenomena (energy waves) from sources such as lightning discharge, rotating electrical machinery, welding equipment, electronic equipment, and radio or television transmission. Electromagnetic noise degrades signals generated by electronic equipment and impairs performance.
End of File Character (EOF) -- Sent at the end of a file when using IRL. End of Message Character (EOM) - - Sent at the end of reader messages and must be sent at the end of host messages. The transmit and receive EOM characters can be defined separately.
Page G -2 © 1987 INTERMEC Corporation