Troubleshooting with the Supervisory CRT

TROUBLESHOOTING WITH THE SUPERVISORY CRT

The Supervisory CAT is particularly useful in troubleshooting data communication and configuration errors.

To check the configuration parameters, call up the Task Option screens (1, 2, 3, or 6) from the Master Menu. See Section 5, "Configuring the Controller,” for instruction on how to display these screens and modify the parameters settings.

Screens 4, 5, and 6, accessible from the Master Menu, are useful for finding errors. Section 8, “CRT Control of 9154 Communication,” provides detailed information on the general use of screens 4, 5, and 6. This section provides suggestions for using these screens to find errors in the data communication protocol. It covers the following diagnostic operations:

. Isolate data communication and protocol errors and determine what caused the error.

+ Determine if the polled devices are communicating effectively with the controller.

. Determine which device addresses are being used.

To use this section, call up the Master Menu. The Supervisory CRT must be physically connected and configured, as described in Section 4, "Installing Hardware,” and Section 5, “Configuring the Controller.”

Isolate Data Communication and Protocol Errors

To isolate errors call up the Display Error Messages screen by entering [4], [CR] at the Master Menu screen. The Display Error Messages screen displays the last 20 errors recorded by the controller. As new errors occur, they scroll onto the bottom of the screen, so the list of displayed errors is continuously updated. Figure 10-1 shows a sample Display Error Messages screen.

© 1987 INTERMEC Corporation Page 10-5

Page 282 read from a scan by OCR; it may hold reading errors

TROUBLESHOOTING

01:00:03 01:00:05 01:00:09

Display Error Messages HH:MM

Device A: Parity Device D: Framing Device K: Overrun

01:00:21 Host Transmit Error: Parity,

01:00:34 Host Receive Error:

01:01:01 Power Interrupt

LRC

01:03:46 Device 3: Xmit Problem

CNTL-Q to Start Review

Framing

CNTL-S to Stop Review Press CNTL-T For Listing of Task Options

Figure 10-1

Displaying Error Messages

Troubleshooting Hints: !f occasional data communication errors occur, for example “Host Transmit Error: NEG Received," there may be nothing wrong; in normal data communication some errors may occur. The data communication protocol should take care of the problem by requiring messages to be repeated.

Page 10-6

© 1987 INTERMEC Corporation

Page 283 read from a scan by OCR; it may hold reading errors

Troubleshooting with the Supervisory CRT

However, if the “common” errors occur too often, there is probably something wrong with the data communication protocol. For example, if Overrun errors occur regularly, it may be necessary to change the baud rate at which devices are polled. Changing the baud rate involves changing the controller baud rate setting for polling devices, and setting all the polled devices to the new baud rate.

Some errors are fatal, for example, Power Interrupt. Until power is returned, no communication will occur. Section 9, "Power Failure and Recovery,” explains in detail how the controller handles power interruption.

Device Errors: For device errors, the Display Error Messages screen also shows the address where the error occurred. If a particular address has many errors, it probably indicates that the device, or devices, with that address has problems. For example, two devices could have been configured with the same address, and, thus, be trying to drive the line at the same time. (This could result in a series of parity and framing errors recorded for one particular address.)

Host Receive Errors: When the host has initiated the select sequence to send the controller a message, any error found by the controller during the transaction will be a "Host Receive Error.” The controller will expect the data to be retransmitted by the host.

Host Transmit Errors: If the host polls the controller or a specific device and an error is found by the controller during the transaction, it will be a "Host Transmit Error.” For example, if the controller has sent a message, and a parity error is detected in the hosts response, it would be a “Host Transmit Error: Parity.” The controller will retain the data for automatic re-transmission.

Time of Occurrence: Each error message is accompanied by the time at which it occurred. The time of occurrence precedes the error message, and is recorded from the controller's real time clock in the following format:

00:00:03 DD:HH:MM

DD Day

HH Hour MM Minute

© 1987 INTERMEC Corporation Page 10-7

Page 284 read from a scan by OCR; it may hold reading errors

TROUBLESHOOTING

Since the errors will remain even if the controller power is turned off, be careful to record and review which errors occur before and after changes were made to the configuration parameters or the physical set up. The errors that are displayed may be the result of past problems that have since been corrected.

Error Types: With the mix of data link and error types there are a variety of error messages that may be displayed on the screen. The error messages are listed alphabetically below by error type, along with suggested remedies to consider if the error is occurring regularly, or if the occurrence of the error is fatal. Device errors are listed first, then the combination of Host Transmit and Host Receive Errors, followed by controller errors.

Device (Device Address): Buffer Overflow

The controller is receiving too much information from the devices. The devices are sending information too fast, or sending too much information (more than 254 bytes) at one time. Check the baud rate for controller to polled devices communication. Fix polled device communication protocol so that it sends records that are shorter.

Device (Device Address): Framing A stop or start bit was not found where it should be. If this error occurs regularly, check the device baud rate.

Device (Device Address): Illegal data The data link worked but the format of the data was in error. Check the device configuration. Inspect for hardware failure of the device.

Device (Device Address): LRC

The controller is receiving the wrong LRC from the device for the transmitted message block. If this error occurs occasionally, Multi-Drop protocol will retransmit the message automatically and nothing else needs to be done. if this error occurs regularly, the Multi-Drop line is probably receiving electro-magnetic interference.

Device (Device Address): Overrun

The controller receive buffer is full. The controller is receiving information from the devices at a faster rate than it can process it. This is a firmware check; consult your local INTERMEC service representative.

Page 10-8 © 1987 INTERMEC Corporation

Page 285 read from a scan by OCR; it may hold reading errors

Troubleshooting with the Supervisory CRT

Device (Device Address): Parity

For the given message, the parity bit was the wrong one to match the even parity required by Multi-Drop protocol. This is a UART error; check that baud rate and parity are configured correctly.

Device (Device Address): SOM not received

No Start of Message character was received. Check configuration of polled devices where error occurs. Ensure devices are operating with Multi-Drop protocol.

Device (Device Address): Timeout

The device did not send data or respond before the timeout limit was reached after the controller sent a message to the device. Check configuration of controller and polled device, particularly the timeout setting.

Device (Device Address): Xmit problem

NEG received by controller, indicating that the device did not receive that transmission. Since the controller will re-send message there is no problem unless this error occurs continuously. If this error occurs continuously, check the configuration of any Multi-Drop device where this error occurs, and ensure that they are set to Multi-Drop protocol.

Host Receive Error: Buffer Overflow The controller is receiving too much information from the host.

Host is sending information too fast, or too much information at one time (more than 512 bytes). Check host to controller configuration. Adjust host communication protocol so that it does not send so much information.

Host Receive Error: Framing or Host Transmit Error: Framing A stop bit or start bit was not found where it should be.

If this error occurs regularly, check baud rate of controller. Check baud rate of host if adjustment of controller baud setting does not correct this problem.

Host Receive Error: Illegal data

Data link worked, but the format of data is in error. Data was either not a valid command, or the device address was invalid. Check the host application program. Check which device addresses are enabled on the Supervisory CRT Select Polled Devices screen.

© 1987 INTERMEC Corporation Page 10-9

Page 286 read from a scan by OCR; it may hold reading errors

TROUBLESHOOTING

Host Receive Error: LRC

LRC is not set correctly or controller is receiving wrong LRC from host. If this error occurs occasionally, there is no problem, if the host re-transmits the message automatically. If this error occurs regularly, the host-to-controller line is probably receiving electro-magnetic interference.

Host Transmit Error: NEG received

Host did not receive transmission. Since controller will re-send the message, there is no problem, unless this error occurs continuously. If the error occurs continuously, check the communication protocol of both the host and the controller.

Host Receive Error: Overrun or Host Transmit Error: Overrun

The controller receive buffer has received too much information from the host. The controller is receiving information from the host faster than it can process it. This is a firmware check, consult your local INTERMEC service representative.

Host Receive Error: Parity or Host Transmit Error: Parity

For the given message, the parity bit was the wrong one to match the configured protocol. This is a UART error; check that baud rate and parity are configured correctly.

Host Receive Error: SOM not received

No Start of Message character; the problem depends on the protocol used. Check that both the host and the controller are set up for the same type of solicited or unsolicited protocol. Check that the configuration of the SOM on the controller matches the host protocol.

Host Receive Error: Timeout or Host Transmit Error: Timeout

Host did not send data or respond before the timeout limit was reached, after the controller sent a message to the host. Check configuration of controller, especially timeout setting.

Polled Device Buffer Full

Controller polled device buffer has reached its limit for receiving information. Check for a device that is sending information continuously without operator usage. Check that all devices are set up for Multi-Drop protocol. If the host computer has not been processing information received from the controller, it should do so now.

Page 10-10 © 1987 INTERMEC Corporation

Page 287 read from a scan by OCR; it may hold reading errors

Troubleshooting with the Supervisory CRT

Power Interrupt

An interruption of power caused the firmware protection circuit to be invoked; information in RAM is protected by the battery-backup circuitry. After power is returned, past data will be processed before the normal power up routine is performed. See Section 9, “Power Failure and Recovery,” for a more detailed explanation of how the controller handles power interruptions.

Determine If the Polled Devices Are Communicating with the Controller

To determine if the polled devices are communicating with the controller, run the following test:

1. Call up the Display Buffer Review screen from the Master Menu by entering [5] and then pressing [CR] to select Task Option 5.

The Display Buffer Review screen will be displayed on the Supervisory CRT. This screen calls up the polled device FIFO (First In, First Out) buffer and allows you to view any records stored. If the time append is enabled, the time that records enter the FIFO buffer is displayed. Figure 10-2 illustrates the Display Buffer Review screen with time appended every minute.

© 1987 INTERMEC Corporation Page 10-11

Page 288 read from a scan by OCR; it may hold reading errors

TROUBLESHOOTING

Display Buffer Review HH:MM

41234567 SDATA1 234567890

>01:00:09 3DATA343533242234234-98

301:00:10

CNTL-Q to Start Review CNTL-S to Stop Review Press CNTL-T For Listing of Task Options

\.

Figure 10-2 Displaying Buffer Review

Page 10-12 © 1987 INTERMEC Corporation

Page 289 read from a scan by OCR; it may hold reading errors

Troubleshooting with the Supervisory CRT

2. Step through the buffer until the most recent data records are displayed.

Press [CNTL] [Q] to start the buffer review. The controller will continuously write data (oldest records first) to the Supervisory CRT screen a line ata time. The records will appear on the screen starting at the top; once the screen area is full, they scroll up from the bottom. If the CRT has a scrolling or roll mode, this mode should be selected. The review can be stopped by entering [CNTL] [S], and restarted by entering [CNTL] [Q]. After all the data in the buffer has been displayed, the controller will display more data as it is received.

3. Transmit a message from the polled device to the controller.

a. With a reader, scan a bar code symbol, know to be "good," for which the human-readable representation is known, like the following bar code:

*TEST LABEL* b. With a printer, use the communications diagnostic test or request the printer status. Use the Supervisory CRT Send Messages to Polled Devices screen to request printer status. See the printer manual for the specific commands and procedure.

© 1987 INTERMEC Corporation Page 10-13

Page 290 read from a scan by OCR; it may hold reading errors

TROUBLESHOOTING

4. Look for a new record displayed on the Display Buffer Review screen.

The address of the polled device is indicated by the first character of the data entry.

If the polled device can not accurately transmit/receive data from the controller, do the following:

. Check the hardware interface and cable connections between the polled device and the input device and between the polled device and the controller.

. Check the power supply connection to the polled device and to the outlet.

. Check the configuration of the polled device.

. Enter [CNTL] [R] from the Supervisory CRT to ensure the controller is polling the devices.

° If the device is a reader, review proper scanning techniques in the wand or scanner operation guide.

5. Repeat steps 3 and 4 for as many of the polled devices as desired. 6. Enter {CNTL] [7] to return to the Master Menu screen.

Determine Which Device Addresses are Being Used

To determine which addresses are in use, check device address status on the Select Polled Devices screen on the Supervisory CRT. The Select Polled Devices screen allows the user to check which Multi-Drop addresses are enabled or disabled, and also which of the enabled addresses are being used. For more detailed information about the Select Polled Devices screen, see Section 8, “CRT Control of 9154 Communication.”