Page 311
Appendix C
APPENDIX C: ASCIi CONTROL CHARACTERS
NUL Null character. This character is non-printing time delay or filler character.
SOH Start of Heading. Used in bysync data streams to denote the start of message heading data block.
STX Start of Text. Signals the end of heading data and the beginning of information data.
ETX End of Text. Informs the receiver that all information data has been transmitted.
EOT End of Transmission. Indicates the end of transmission of all data associated with a message.
ENQ Enquiry. Request a response.
ACK
Acknowledgement. Used to verify proper communication between transmitter and receiver.
BEL Bell. Signals a situation that requires human intervention.
BS Backspace. Used to control the active print position of the cursor and printer.
©1987 INTERMEC Corporation Page C-1
Page 312
APPENDIXES
HT Horizontal Tab. Causes the cursor to move to the next predetermined position before printing.
LF Line Feed. Causes the cursor to advance to the same column position in the next line of text.
VT Vertical Tab. Causes the cursor position to advance to the same columna predetermined number of lines down from the present line.
FF Form Feed. Used to advance a print head to the next logical top of form or toa predetermined line of the next form or page.
CR
Carriage Return. Used to advance the active print or display position to the first column of the same line. Unless the carriage return is followed by a line feed, the characters that follow the carriage return will overstrike characters already printed on the line.
so Shift Out. Extends the standard graphics character set.
Sl Shift In. Resets to the Standard ASCIi character set.
DLE Data Link Escape. Used to modify the meaning of a limited number of subsequent characters.
DC1
Device Control 1. An electronic toggle switch. This character is often designated as XON and is used to re-initiate the listing of a file that was temporarily halted by a DC3 character.
Page C-2 ©1987 INTERMEC Corporation
Page 313
Appendix C
DC2 Device Control 2. An electronic toggle switch. Varies with vendor application.
DC3 Device Control 3. An electronic toggle switch. This character is often designated as XOFF and is used to temporarily halt the listing of a file.
DC4 Device Control 4. An electronic toggle switch. Varies with vendor applications.
NAK Negative Acknowledgement. Used to indicate improper transmission between a transmitter and a receiver.
SYN Synchronous Idle. Used in the bisync protocol to initiate or maintain communication synchronization when no data is being transmitted.
ETB End of Transmission Block. Used to indicate the end of a particular block of transmitted data.
CAN Cancel. Varies with vendor application, but is generally used to denote an error in data transfer.
EM End of Medium. Used to indicate either the physical end of a data medium or the end of a portion of data medium containing desired data.
SUB Substitute. Used for data communication accuracy control.
ESC Escape. Used for communications with printers.
©1987 INTERMEC Corporation Page C-3
Page 314
APPENDIXES
FS File Separator. An information separator control character used to mark a logical boundary between files being transferred.
GS Group Separator. An information separator character used to mark the logical boundaries between groups of transmitted data.
RS Record Separator. An information separator character used to mark logical boundaries between records.
us Unit Separator. The final information separator character.
DEL Delete. Not actually a character but is used to erase or obliterate characters.
SP Space.
Page C-4 ©1987 INTERMEC Corporation
Page 315
Appendix D
APPENDIX D: FULL ASCII CHART FULL ASCil Binary® Hex' Dee? C393 Chart | Binary Hex Dec C39 Char Controi Character Definitions> 00000000 00 00 %U NUL 01000000 40 64 %V NUL Null, or all zeroes
00000001 01 01 00000010 02 02 00000011 03 03
SA SOH 01000001 41 $8 STX 01000010 42 $C ETX 01000011 43
SOH Start of Heading STX Start of Text ETX__End of Text
00000100 04 04
$0 €£OT 01000100 44 EOT End of Transmission
00010000 10 16 00010001 11 17 00010010 12 18 G0010011 13 19
00000101 05 05 SE ENQ 01000101 45 ENQ Enquiry 00000110 06 06 $F ACK 01000110 46 ACK Acknowledgement 00000111 07 07 $G BEL 01000111 47 BEL Bell
00001000 08 08 $H 6S 01001000 48 BS Backspace 00001001 09 09 $1 HT 01001001 49 HT Horizontal Tab 00001010 OA 10 $u LF 01001010 4A LF Line Feed 00001011 08 u $K VT 01001011 4B VT___ Vertical Tab 00001100 OC 12 SL FF 01001100 4C FF = Form Feed 00001101 OD 13 CR 01001101 4D CR Carriage Return 00001110 0& 14 so 01001110 4E Shift Out 00001111 OF 15 Si 01001111 4F SI Shift In
DLE 01010000 50 OCi 01010001 51 oc2 01010010 52
OLE Data Link Escape
DCi Device Control 1 (XON) OC2 Device Controt 2
DC3_ Device Control 3 (XOFF)
00010100 14 20 00010101 15 21 00010110 16 22 00010111 17 23 00011000 18 24
0C4 01010100 54 NAK 01010101 55 SYN 01010110 56 ETB 01010111 57 CAN 01011000 58
OC4 Device Control 4
NAK Negative Acknowledge SYN Synchronous Idle
ETB End Transmission Block CAN Cancel
N<XSE<CANHDOVOZEO AG TONMMOOWP>s
Mi N O P O R S__DC3 0101001153 T U Vv Ww Xx YY Z
IK IANKKSKCHODOVOZSH|ASTIONMOGOV>O n (o)
Ssegesgesssaeseessssarresesusraranzesaas
00111100 3C 60 00111101 3D 61 00111110 3E 62 O01 3F §3
00011001 19 25 § EM 01011001 59 EM_ End of Medium 00011010 1A 2 § SUB | 01011010 5A SUB Substitute 00011011 1B 27 %A ESC 01011011 5B %K ESC Escape 00011100 1C 28 %B FS 01011100 5C %L FS File Separator 00011101 1D 29 %*C GS 01011101 5D %M GS = Group Separator 00011110 1E& 30 %0 ARS 01011110 5E %N RS Record Separator Qoo1i111 iF 31 %E US 01011111 SF %O, US Unit Separator 00100000 20 32 SP _ SPé 01100000 60 %wW SP Space 00100001 21 «33° «C/A 01100001 61 +A a DEL Delete 00100010 22 34iCB 01100010 62 +8 Ob 00100011 2335 IC 01100011 63 +C cc 00100100 24 «#8936 =ID OS 01100100 64 +D d Not 00100101 25 37s Ei 01100101 65 +E @ ,__ Notes 00100110 26 «638 IF & 01100110 66 +F of 0 Bit positions are 76543210 00100111 27, 39,ssGst 01100111 67 +G Qg 1 Hexadecimal value 00101000 28 4940 IH ( 01101000 68 +H A 2 Decimal value 00101001 29° «41s Il ) 01101001 69 +h 3 Code 39 character(s) 00101010 2A 42) J * 01101010 6A +30 j 4 ASCII character 00101011 2B 43 IK + 01101011 6B 107 +K_k § Hold down Control key 00101100 264g 01101100 6C 108 +L | and press key (o left of 00101101 20 45 IM - 01101101 6D 109 +M m gefinttion P 00101110 2E «46 NS; 01101110 6E 110 +N on 6 SP is the SPACE 00101111 2F 47 10 7 01101111 GF 111 +0 o character 00110000 30. 48 «=1P? «0 01110000 70 112 +P p 7 The Code 39 characters 00110001 31 49 «Qt 01110001 71. «113 +Q q IP through /Y may be 00110010 32 50 JR 2 01110010 72 114 +R oF interchanged with the 00110011 33. 551 S38 01110011 73 115 4S 5 8 Rembers 0 through 9 ith 00110100 34° 52. TG 01110100 74 «116 =4T +t OX OF WY Ores 00110101 35 «953 UC 01110101 75 «117 +#U 9 Mis the DELETE 00110110 36 «54 VO 01110110 76 4118 4+V ov character OO110111 37 55 IW 7? 01110111 77 119 +W ow 00111000 38 «656 «6X 8B 014111000 78 120 +X x oo111001 39 «57 «IY 9 01111001 79 121 +Y y O0111010 3A «58 OZ: O111010 7A 122 4+Z Zz OO11011 38 59 %F_ ; 01111011 78 123 %P {
]
}
01111100 7C 124 %Q 01141101 70 125 %R 01111110 7E 126 %S ~
Own 7F 127° %T? me s My Ar imi. ge
01
March 1988
©1987 INTERMEC Corporation Page D-1
Page 316
Page 317
INDEX
A
Address assigning for devices, 6-7, 6-9 determining available, 10-14 multi-drop port, 5-19, 6-3 tracking usage, 6-11 AFF, 5-25, 5-29 Append time to data command format, 5-35, 8-30 ASCII control characters defined, C-1 conversion chart, D-1 entering control characters, 5-23 Authorized service locations, 1-5 Automatic baud rate detection sequence, 5-4
B
Battery storage, 11-6 to protect data, 2-8, 9-3 warning about, 1-11 Baud Rate controller, 5-16, 5-18 device, 6-7, 6-9 supervisory CRT, 5-4, 8-18 warning about, 1-10, 6-7, 6-9 Buffer review screen, 8-39, 10-12 Buffering capability, 2-2, 2-8
© 1987 INTERMEC Corporation Page I-1
Page 318
INDEX
Cc
Cabling multi-drop requirements, 3-4, 4-27 RS-232 (host), 4-17 RS-422/485, 4-21 Caution definition, 1-7 summary of, 1-7 Checklist data communication, 3-26 troubleshooting, 10-2 verifying configuration, 5-44 verifying system installation, 4-36 Clear screen sequence, 5-6 Clock real time, 2-8, 5-34 Commands enter, 5-11 sent from host, 7-41 Communications standards supported, 2-2 Compatible INTERMEC devices, 2-11, 6-5 Configuration controller, 5-2 default settings, 3-27, B-1 device addresses, 6-7, 6-9 downloading from host, 7-40 for non-standard CRT, 5-5 multi-drop parameter, 6-8 restore factory settings, 8-7 Connection controller to CRT, 4-13 controller to ground cable, 4-8 controller to host, 4-16, 4-19 controller to modem, 4-22 controller to polled device, 4-23 controller to power supply, 4-9
Page I-2 © 1987 INTERMEC Corporation
Page 319
INDEX
Controller components location, 2-4 connections, 2-4 features, 2-8 front panel, 2-4 rear panel, 2-5 sample system, 2-12 CrossBar network definition, 2-12 design considerations, 3-2 CRT connector, 2-4 configuration, 5-3 type supported, 5-4 see also “supervisory CRT” Current loop interface adapter, 2-2, 4-23 installation, 4-23 when to use, 3-11 Cursor address command sequence, 5-7 Cursor row and column positions, 5-7 Cycle time poll, 3-21 select, 3-22
D
Daisy chain configuration defined, 3-6 Data bits, 5-18 Data communication considerations, 3-26 multi-drop, 6-3 see also “protocol, host interface” Data entry commands, 5-13 Default configuration settings, 3-27 Delay timer, 5-30
© 1987 INTERMEC Corporation Page I-3
Page 320
INDEX
Devices compatible with controller, 2-11 configuration of, 6-2, 6-5, 6-7 messages sent by, 8-39, 10-11 sending messages to, 8-44 specific polling, 7-8 terminology defined, 1-13 to start and stop polling, 5-14 total number allowed, 2-2, 3-5 Dimensions, controller, A-2 Disconnecting the power supply, 4-12, 11-4 Display buffer review screen, 8-39, 10-12 Display error messages screen, 8-33, 10-6 DLE character definition, 5-29 in transparency check, 7-12 Drop cabling, multi drop allowable lengths, 4-26, 4-30 attaching to trunk cable, 4-32, 4-34 cable part number, 4-30 Drop line configuration definition of, 3-6 installation, 3-6, 3-7
E
EEPROM copy of configuration parameters, 8-9 saving parameters, 5-11, 5-14, 8-5 Enable time broadcast, 5-38, 8-31 Entering ASCII contro! characters, 5-23 Environmental specifications, A-3 EOM importance of, 5-44 in message block, 7-5, 7-6 EOR in data record, 7-5, 7-7
Page I-4 © 1987 INTERMEC Corporation