Page 251
Select Clock Parameters Screen
SELECT CLOCK PARAMETERS SCREEN if "3" is entered for the Task No. on the Master Menu, the Select Clock Parameters screen shown in Figure 8-6 will be displayed on the Supervisory CRT. The Select Clock Parameters screen lets you control the way the controller's real time clock is used.
Select Clock Parameters HH:MM Set Real Time Clock: Date we. cece eneeenee YY.MM.DD (YY.MM.DD) Time .....ee ee ee ee eee HH.MM (HH.MM) Press CNTL-Y to Set Clock Time Append: Enable Time Append ...N (Y or N) Interval ..... eee eens 1 (0-99 minutes) Record Day Rollover .. N (Y or N) Time Broadcast: Enable Broadcast ..... N (Y or N) Interval ............. 1 (0-99 minutes) Preamble ............. <KT> Postamble ...........- Display Format ....... 24 (12 or 24) Include YY/MM/DD.-..-.-.- N (Y or N) Press CNTL-X to Cancel Line Press CNTL-T Return to Task Options Press ESC to Update EEPROM \
Figure 8-6 Select Clock Parameters Screen
© 1987 INTERMEC Corporation Page 8-27
Page 252
CRT CONTROL OF 9154 COMMUNICATION
Select Clock Parameters Screen Layout
The time on the controller real time clock time is displayed in the upper right corner in the following format:
HH:MM
HH is hours in 24 hour format. MM is minutes.
The working part of the Select Clock Parameters screen is divided into three sections:
1. Set Real Time Clock 2. Time Append 3. Time Broadcast
The screen is made up of three columns. The first column gives the parameter name. The second column contains data fields for entering parameter values and lists the current setting for each parameter. The third column, if it exists, lists the possible values for the parameter.
Except for the Set Clock command, all commands that can be invoked from the Select Operating Parameters screen are listed at the bottom of the screen. The Set Clock command is listed just after the Set Real Time Clock parameters display.
When the Set Clock command is invoked, the time is updated on the the controller real time clock and displayed in the upper right corner of all the screens.
Page 8-28 © 1987 INTERMEC Corporation
Page 253
Select Clock Parameters Screen
Set Real Time Clock
Set Real Time Clock is used to set the time and date on the controller's real time clock. The current default date and time are displayed just to the right of the prompts.
Date: The date is entered in the following format: YY.MM.DD
YY Year, two digits (00-99). Delimiter, must be entered.
MM Month, two digits (01-12). Delimiter, must be entered.
DD Day, two digits (01-31).
Time: The time must be entered in the following format:
HH.MM
HH Hours, two digits, 00-23 (24 hour clock).Delimiter separating Hour and Minute, must be present.
MM Minutes, two digits, 0-59.
The controller real time clock counts seconds; however, seconds is nota configurable parameter. If a new time value is entered, the delimiters must be present. When the time is updated using the Set Clock command, [CNTL] [Y], the time displayed in the upper right hand corner of all the screens will change.
© 1987 INTERMEC Corporation Page 8-29
Page 254
CRT CONTROL OF 9154 COMMUNICATION
Time Append Parameters Three Time Append parameters configure the controller for appending time records to the data records received from the polled devices.
Enable Time Append: This parameter determines if time is appended to the data records, using the format specified in the next two parameters. Two values are allowed:
Y Yes, enable time append, add time records.
N No, disable time append, do not add time records.
Time Interval: The Time Interval parameter specifies the length of time in minutes between the addition of time records to the data received from the polled devices. The interval may be up to two digits (0-99).
Record Day Rollover: The Record Day Rollover parameter determines whether or not a data record will be added to the polled device buffer at 12:00 PM when the day changes. Two values are allowed:
Y Yes, enable Day Rollover, adda time record at midnight.
N No, disable Day Rollover, do not add a time record.
If Time Append is enabled, but the Time Append Interval is zero, the controller will append time to every record. The format of the record is:
Data>DD:HH:MM
Where Data is the data record, and DD:HH:MM is the time record in the Day, Hour, Minute format.
If Time Append is enabled, and the Time Append Interval is a non-zero value, a time record is added as a separate record to the data waiting to be sent to the host. The format is:
>DD:HH:MM
Page 8-30 © 1987 INTERMEC Corporation
Page 255
Select Clock Parameters Screen
Time Broadcast Parameters
Six time broadcast parameters configure the controller to send time messages to the polled devices for display on their screen. The time message is displayed left-justified on the device screen.
Enable Time Broadcast: This parameter determines if time is broadcast to the polled devices, using the format in the next five parameters. Two values are allowed:
Y Yes, enable time broadcast, send time messages.
N No, disable time broadcast, do not send time messages.
Interval: The Interval parameter specifies the length of time between broadcasts in minutes, The interval may be up to two digits (0-99).
Preamble: The Preamble parameter allows a short message to be displayed before the time message on the polled devices. The message may be one to five ASCII characters long, or the field may be left blank.
Postamble: The Postamble parameter allows a short message to be displayed after the time message on the polled devices. The message may be one to five ASCII characters long, or the field may be left blank.
Display Format: The Display Format parameter determines whether the time is represented in a 12-hour or 24-hour format. The allowable values are:
12 For 12-hour format. 24 For military time, in the 24-hour format.
© 1987 INTERMEC Corporation Page 8-31
Page 256
CRT CONTROL OF 9154 COMMUNICATION
Include YY/MM/DD: The include YY/MM/DD parameter allows the current year, month, and day on the real time clock to be added to the time message broadcast to the polled device. Two values are allowed:
y Yes, include year, month, and day in the time messages.
N No, do not include year, month, and day in the time messages.
If Time Broadcast is enabled, time will be sent to the polled devices in the following format:
< preamble > HH:MM < postamble > if there are no preamble or postamble, those fields will be missing, and the rest of the message will be left-justified.
If Include YY/MM/DD is enabled, the time is sent in the following format:
< preamble > YY/MM/DD:HH:MM <postamble >
Page 8-32 © 1987 INTERMEC Corporation
Page 257
Display Error Messages Screen
DISPLAY ERROR MESSAGES SCREEN
\f "4" is entered for Task No. on the Master Menu, the Display Error Messages screen shown in Figure 8-7 will be displayed on the Supervisory CRT. The last
20 "errors" recorded by the controller will appear on the screen.
~ Display Error Messages HH:MM 01:00:03 Device A: Parity 01:00:05 Device D: Framing 01:00:09 Device K: Overrun 01:00:21 Host Transmit Error: Parity, Framing 01:00:34 Host Receive Error: LRC 01:01:01 Power Interrupt 01:03:46 Device 3: Xmit Problem CNTL-Q to Start Review CNTL-S to Stop Review Press CNTL-T For Listing of Task Options \. _/
Figure 8-7 Display Error Messages Screen
© 1987 INTERMEC Corporation
Page 8-33
Page 258
CRT CONTROL OF 9154 COMMUNICATION
The time on the controller real time clock time is displayed in the upper right hand corner in the following format:
HH:MM
HH is hours in 24 hour format. MM is minutes.
Display Error Messages Screen Operation
This screen displays the last twenty errors that occurred in system operation. You can scroll through the error buffer by entering [CNTL] [Q] to start the review of the errors, and the [CNTL] [S] to stop the review when desired. The errors will remain on the screen until they are replaced with new errors which scroll onto the bottom of the screen. Thus, the most recent error recorded appears at the bottom of the screen, and the oldest error is displayed at the top of screen. To facilitate scrolling, the Supervisory CRT should be in scroll mode.
If multiple errors occur for a single transmission event, they may be listed together separated by commas. For example, in Figure 8-7, one host transmission event had both a parity and a framing error.
The Display Error Messages screen only displays errors generated by the controller in response to data communications received from the host computer or the polled devices. Errors generated by the host from data received from the controller will not be displayed.
Error Format Each error event occupies its own distinct screen line. Three basic error formats exist: device, host, and controller.
Page 8-34 © 1987 INTERMEC Corporation
Page 259
Display Error Messages Screen
Device Errors: Errors that occur in the data communication between the controller and the devices have the following format:
01:00:03 Device A: Parity
01:00:03 indicates that a Time the error occurred. Device identifies the error as a device error.
Ais the Device address at which the error occurred.
Parity is the name of the error type.
Host Errors: Errors that occur in the data communication between the controller and the host have one of the two following formats:
01:00:21 Host Recelve Error: Parity 01:00:21 indicates the time the error occurred.
Host Receive Error identifies the error as one that occurred in the host to controller data link when the host was sending data, the select procedure.
Parity is the name of the error type 01:00:21 Host Transmit Error: Parity 01:00:21 is the time the error occurred.
Host Recelve Error identifies the error as one that occurred on the host to controller data link when the Controller was sending data, the poll procedure.
Parity is the name of the error type.
Errors on the host to controller data link may occur anywhere in the transmission event. For example, if there is a parity error in the host's AFF response, after the host solicits data from the controller, it is a Host Transmit Error because the controller was transmitting a data message to the host (even though the error occurred in data link protocol received by the controller). Because of the error, the whole event was nullified and the controller will have to transmit the data again.
© 1987 INTERMEC Corporation Page 8-35
Page 260
CRT CONTROL OF 9154 COMMUNICATION
Controller Errors: Errors related to controller operation have the following format:
01:01:01 Power Interrupt 01:01:01 Time of error occurrence.
Power Interrupt Name of error type.
Time: Indicates when the error occurred. The time is taken from the controller real time clock. This field precedes the error message. The time is represented in the following format:
DD:HH:MM
DD Days, (1-31)
HH Hours, (0-23), 12-hour or 24-hour clock depending upon real time clock format.
MM Minutes, (0-59). An example of the format taken from Figure 8-7 follows:
01:00:03 Device A: Parity
Error Types
Over 20 distinct types of errors can be displayed on the screen. All the error message displays will be preceded by the time the error occurred. Section 10, “Troubleshooting” explains what the regular occurrence of a particular type of error means. The error types below are listed alphabetically by error type, with Device errors first, Host errors second, and Controller errors last.
Page 8-36 © 1987 INTERMEC Corporation