Page 151
Select Clock Parameters
To disable the Preamble, enter [CNTL] [X], [CR]. The [CNTL] [X] command clears the parameter field, and the [CR] enters the blank field, disabling the parameter.
To enter a new message, type over the existing message, and then press [CR]. For example, to display "Time" before the time broadcast, type "Time" and press [CR]. The preamble must be the single character HT for INTERMEC readers with a display to right-justify the time data on the display.
Postamble: The Postamble parameter allows a short message to be placed after the time broadcast. Like the Preamble, this parameter can contain one to five ASCII characters or be left blank to signify that it is disabled. If a message longer than five characters is entered, the Supervisory CRT will beep, and the message will be truncated to the first five characters.
The default value for Postamble is disabled. If this is satisfactory, press [CR].
To display a postamble after the message, enter the message and [CR]. For example, type "Time" and press [CR] to enter Time as a postamble.
Display Format: The Display Format parameter selects which of the two hour formats to use. The two formats are: military (or 24 hour) and standard 12-hour time.
The default value is 24-hour time. If this time format is acceptable, press [CR].
To change the Display Format to 12-hour time, type “12” and then press [CR].
Include YY/MM/DD: When Include YY/MM/DD is enabled, the year, month, and day are transmitted as part of the time message.
The default for include YY/MM/DD is disabled. If this is satisfactory, press [CR].
To enable include YY/MM/DD and broadeast year, month, and day as part of the Time Broadcast, enter [Y], then press [CR].
© 1987 INTERMEC Corporation Page 5-39
Page 152
CONFIGURING THE CONTROLLER
Saving Clock Parameters Review the Select Clock Parameters displayed on the screen and change if necessary.
Then save the parameter values, re-initialize the controller, and return to the Master Menu by using one of the two following commands:
[CNTL] [7] Save the Select Clock Parameters to RAM. {ESC} Save the Select Clock Parameters to RAM and EEPROM.
See "Saving Parameters" earlier in this section for detailed information about saving parameters.
Page 5-40 ©1987 INTERMEC Corporation
Page 153
Select Polled Devices
SELECT POLLED DEVICES
The device addresses polled by the controller are selected using the Select Polled Devices screen. To display the Select Polled Devices screen, enter [3], then press [CR] from the Master Menu. The cursor will be positioned by the status for the first address, A.
Select Polled Devices HH :MM
DeVite Statiis (F-EnabTéed;D=prsabléd) Device Status (E=Enabled, D=vrsabTed)
VOMZEMeAQHnyron mmooawver BPMN M AMMO M HMMA UBWHKrONKX ECCHHNDO OMOM MAMMA OAM MMMM
Press CNTL-T For Listing of Task Options \ Press ESC to Update EEPROM
The controller comes from the factory with all device addresses enabled for polling. To increase the efficiency of the device polling, addresses where a device will not be connected should be disabled. You only need to enable those addresses where polled devices are connected to the controller's Multi-Drop port.
Note: The Select Polled Devices screen will be updated and redisplay if the host modifies the addresses that are enabled/disabled using a host command.
© 1987 INTERMEC Corporation Page 5-41
Page 154
CONFIGURING THE CONTROLLER
Enabling Device Addresses Use the following procedure to enable only as many addresses as needed by your devices.
1. Count the number of devices (readers and printers) that are physically installed on the main trunk cable extending from the polled device connector on the rear of the controller.
2. Move the cursor to the first address to be disabled. For example, if you have six devices connected to the main trunk cable, move the cursor down to the seventh address, G.
For ease of tracking, it is recommended that addresses be enabled starting with A and progressing to 5. However, you can arbitrarily and at random chose which addresses will be enabled. Ensure that there is an enabled address for each device, and you keep track of which addresses are enabled.
Note: To facilitate configuring the polled devices, keep a list of the Multi-Drop addresses that are enabled on the controller.
3. Disable each of the rest of the addresses by entering [D] for disable, followed by [CR] to confirm. After each [CR] the cursor will move to the next address. To skip an address, press [CR] without entering D.
Note: Some unused addresses may be left enabled to facilitate adding devices to the main trunk cable.
Page 5-42 ©1987 INTERMEC Corporation
Page 155
Select Polled Devices
4. Review the status of the addresses displayed on the screen and change as necessary.
5. Save the status of the addresses, re-initialize the controller, and return to the Master Menu by using one of the two following commands:
(CNTL] [7] Save the status of the addresses to RAM.
[ESC] Save the status of the addresses to RAM and EEPROM.
See “Saving Parameters" earlier in this section for detailed information about saving the status of the addresses.
6. If the polling of devices was stopped at the start of the configuration session, start polling again by entering [CNTL] [R].
© 1987 INTERMEC Corporation Page 5-43
Page 156
CONFIGURING THE CONTROLLER
VERIFYING CONTROLLER CONFIGURATION
At this point, the controller should be fully configured to communicate with the host and the polled devices. Review the following guidelines to verify a secure protocol environment.
1. The From Host EOM should never be disabled. If the From Host EOM is disabled the reception of data is impossible.
2. It is recommended that the To Host EOM be enabled. If itis not, the host must recognize the end of a message block some other way.
3. It is recommended that both the To Host and From Host SOM be enabled. This gives the data link protocol the ability to always know where a message starts.
4. It is advisable to start all protocol fields with ASCII control characters.
5. It is recommended that the Transparency Check be enabled so that data from polled devices will always be sent by the controller to the host as data only (if data is an ASCII control value, a DLE will precede the data).
6. The From Host DLE should not be disabled. Enabling the From Host DLE allows the host to send any ASCII characters to a polled device as data.
7. If using Unsolicited Receive and Unsolicited Transmit protocol, it is advisable to enable XON/XOFF flow control to ensure secure data communication.
8. Enabling the LRC provides added security to all transmitted and received data messages. Disabling LRC makes the protocol less secure. However, it is advisable to disable the LRC when using XON/XOFF flow control because the calculated LRC could match the XON or XOFF characters.
Page 5-44 ©1987 INTERMEC Corporation
Page 157
Verifying Controller Configuration
9. The AFF/NEG responses (To Host and From Host) allow for verification of successful/unsuccessful communication events. If the event is unsuccessful, this handshake allows the device in error to re-transmit the data. When this handshake is used, no data can be lost since another transmission event can not take place until the affirmative response is received from the previous transmission event. If the AFF/NEG handshake is disabled, data can be lost if the receiving device (controller or host computer) does not successfully get the data the first time.
10. If the controller is configured to transmit more than one record per message block, the EOR should be enabied so that the host application program can discern the individual records. |f multiple records are sent with the EOR disabled, the host application program must discern the end of records some other way. If the AFF/NEG handshake is enabled, the whole message block must be re-transmitted if a NEG response is received from the host.
11. If Data Wait mode is enabled, the communication burden on both the host and the controller is reduced. However, enabling Data Wait mode only makes sense if the From Host POL is enabled.
12. If the From Host SEL is enabled, the controller will send a NEG to the host and not let it send any data until additional buffer space is available.
If the From Host SEL is disabled, the controller will try to buffer whatever data is received. The host can overflow the receive buffer, but if the AFF/NEG handshake is enabled, the host will be asked to re-transmit the data. If the XON/XOFF handshake is enabled, the host will receive the XOFF before overflow occurs.
If the From Host'SEL is disabled, and the AFF/NEG and XON/XOFF handshakes are disabled, the host can overflow the controller's receive buffer, and the data will be lost.
© 1987 INTERMEC Corporation Page 5-45
Page 158
CONFIGURING THE CONTROLLER
SETTING DEVICE ADDRESSES
Once the operating, transmission, clock parameters, and polled device addresses have been configured, the controller is ready for operation. The only task remaining is to configure the polled devices so that they will communicate with the controller.
The devices must be configured to operate at the addresses enabled on the Select Polled Devices screen or they will not be polled. Section 6, “Configuring Polled Devices,” provides guidelines for configuring the polled devices, with particular emphasis placed on selecting device addresses.
See the appropriate operator's manuals for specific directions on configuring the different models of reader and printers.
Page 5-46 ©1987 INTERMEC Corporation
Page 159
SECTION 6
CONFIGURING POLLED DEVICES
INTRODUCTION MULTI-DROP POLLING ON THE 9154 MULTI-DROP PROTOCOL
Selecting Multi-Drop Protocol
Setting Baud Rate Setting the Device Address
USER-DEFINED MULTI-DROP PROTOCOL Configuring a Device’s Communication Parameters Setting Baud Rate Setting the Device Address
TRACKING ADDRESS USAGE
DETERMINING AVAILABLE DEVICE ADDRESSES
© 1987 INTERMEC Corporation Page 6-1
Page 160
CONFIGURING POLLED DEVICES
INTRODUCTION
This section explains how readers and printers connected to the controller must be configured to communicate with a 9154 Controller system. The controller will only work with devices that support Multi-Drop protocol. A list of readers and printers that are compatible with the controller is provided in Section 4.
There are two methods for configuring a device to communicate with the 9154 Controller using Multi-Drop protocol. The procedure you use depends on the model and how the device is used. The two methods are:
1. Multi-Drop Protocoi 2. User-Defined Multi-Drop Protocol
Normally, you use method 1. However, if you have a device like the 9512 Reader that supports IRL (Interactive Reader Language) and you need to define your own IRL download parameters, use method 2, User-Defined Multi-Drop protocol.
Regardless of which method you use, there are three steps to configuring a device to communicate with the controller.
1. | Selecting or configuring Multi-Drop protocol 2. Setting baud rate 3. Setting the device address
This section describes only the requirements for configuring devices used with the controller. For specific information about how to select baud rate, select Multi-Drop protocol, configure communication parameters, and set addresses, see the appropriate reader or printer manual. Depending on the available input devices, the parameters may be entered with a wand, by a keyboard, or using a Supervisory CRT.
Page 6-2 © 1987 INTERMEC Corporation