The text of a manual · part 17 of 33
9154 Line Controller System Manual, pages 161 to 170
Pages 161 to 170 of 330
The original document is the PDF (7.7 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 9154
Page 161
Introduction
After the polled devices have been configured, the controller system should be operational. See Section 10, “Troubleshooting,” for methods of testing system operation.
The controller supports device specific polling, a feature which allows the host to request information from a specific Multi-Drop address. For information about this capability see Section 7, "Host to 9154 Communication.”
MULTI-DROP POLLING ON THE 9154
Multi-Drop polling is accomplished using one main trunk line to carry messages to a series of up to 32 devices. Each of the 32 devices is assigned its own one-character address, A-Z or 0-5. For each address there are distinct POL and SEL characters. Each device can identify information directed to it by the specific POL and SEL character accompanying the message. The POL characters are used to request information from the devices and the SEL characters are used to request permission to transmit to the devices.
The controller starts polling the devices by sending the POL signal for the first enabled address to all the connected devices on the main trunk cable. If there is no response before the time out limit is reached, the controller polls the next enabled address.
To increase the speed at which connected devices are polled, the controller only polls the addresses that are enabled on the Supervisory CRT screen 6, Select Polled Devices. See Section 5, “Configuring the Controller,” for instructions on enabling addresses.
Because the controller is compatible with INTERMEC 9161 02 Multi-Drop Concentrator, the controller's Multi-Drop port is assigned an address (m,n,o, or p) like each of the four Multi-Drop ports on the INTERMEC 9161 02 Multi-Drop Concentrator. The port address becomes part of the device address as illustrated in Figure 6-1. While used when the host computer communicates with the controller, the port address is not used by the controller when polling the devices. The choice of port address is configured on the Supervisory CRT Select Operating Parameters screen. See Section 5, "Configuring the Controller,” for instructions on configuring the controller's Multi-Drop port.
© 1987 INTERMEC Corporation Page 6-3
Page 162
CONFIGURING POLLED DEVICES
Since the device address is a parameter configured on the device, the address is independent of physical location. In Figure 6-1, for example, the addresses are all assigned in order from “A” for the first device to “5” for the device farthest away from the controller on the Multi-Drop line. However, the addresses could just as easily be assigned in reverse order, starting with "5" and ending with “A”, or in no particular order at all. No matter where a device is located along the main trunk line, the device will respond to its own POL and SEL and no others.
For Multi-Drop polling to work, all the devices must operate at the same baud rate as the controller. Baud rate can be configured for both the controller and the devices.
More information about Multi-Drop protocol can be obtained from INTERMEC Data Communication Manual, Part No. 044737.
Multi-Drop Port p (Configurable as m,n, 0, p) Controller Devices A-Z, 0-5 _
J 7 / 7
; | IP] COG] GIG Ge Lo |
Figure 6-1 Multi-Drop Device Addressing Scheme
Page 6-4 © 1987 INTERMEC Corporation
Page 163
Multi-Drop Protocol
MULTI-DROP PROTOCOL
The following readers and printers allow direct selection of Multi-Drop protocol:
9440 Readers (9440 Communication Dock required) 9510 Readers
9511 Readers
9512 Readers
9540 Readers
9550 Readers
863X-Series Printers
864X-Series Printers
If you are using Interactive Reader Language (IRL) with Multi-Drop protocol, your host application program must use the default values for the IRL parameters listed in Table 6-1. If you use IRL download parameter values other than those listed in Table 6-1, you must use User-Defined Multi-Drop protocol. See the next sub-section "User-Defined Multi-Drop Protocol.”
Selecting Multi-Drop Protocol
Select Multi-Drop protocol from the list of protocols displayed on the screen used for protocol selection. For example, 9510, 9511, 9512 Online Readers have their protocol selected in Configuration mode, while 863X-Series Printers have their protocol selected in Options Mode. For specific instructions, see the manual for your device.
© 1987 INTERMEC Corporation Page 6-5
Page 164
CONFIGURING POLLED DEVICES
Table 6-1
IRL (Interactive Reader Language) Parameters
Parameter:
Value:
Default What it does:
EOF EOR
Records
SOP
EOP
RUN
END
PSS
PAK
BAK
SOH NUL
SI
SYN
DC2
So
CR
RS
BEL
The End of File character indicates the end of a file. The End of Record character indicates the end of a record. A value of NUL means the EOR is disabled. Number of program records transmitted per block at one time. If more than one, the EOR should be defined. The Start of Program character notifies the reader that data encountered after the SOP is a block of IRL program statements.
End of IRL Program Block/Continue character is sent after a block of IRL program statements and notifies the reader that another block of IRL statements is being sent.
The Compile and Run IRL Program character indicates the end of a program. If the program is error-free, the reader will run the program.
The End of IRL Program Block/Compile character notifies the reader that the program download is complete.
The Program Statement Separator separates individual IRL program statements within a block.
The PAK character is a Good Program Compile character which the reader sends in response to a downloaded IRL program that compiles error free.
The BAK character is a Compile Error character which the reader sends in response to a downloaded IRL program the contains compile errors.
Note: Use either the RUN or END character at the end of a message, but not both.
Page 6-6
© 1987 INTERMEC Corporation
Page 165
Multi-Drop Protocol
Setting Baud Rate
CAUTION
All devices must be set to the same baud rate as the controller. If all the devices are not operating at the same baud rate, data communication problems will result.
All the polled devices must be set to the same baud rate of transmission as the controller's Multi-Drop port. The other operating parameters, such as the parameter value for parity and the timeout, are all automatically set when Multi- Drop protocol is selected. For specific information about setting the baud rate, see the device manual.
Setting the Device Address
Setting the address involves entering a one character value for the address, A-Z or 0-5. How a device address is selected varies with the model of device. For example, 9510, 9511, 9512 Online Readers have their device address entered in Configuration mode, while 863X-Series Printers have their device address selected in Options Mode. See the manual for your model of device.
The address should be one of the addresses enabled on the Supervisory CRT Select Polled Devices screen. Record the device address in the form provided later in this section under “Tracking Device Addresses.”
USER-DEFINED MULTI-DROP PROTOCOL
If your host application program uses IRL download parameters values different than the default values listed in Table 6-1, standard Multi-Drop protocol can not be used because it will not allow you to change the values of IRL parameters. Instead, you must use User-Defined Multi-Drop Protocol which allows the entering of custom IRL download parameters. When User-Defined Multi-Drop protocol is used, the other device communication parameters must be individually configured to Multi-Drop protocol values or the controller will not be able to communicate with the devices.
© 1987 INTERMEC Corporation Page 6-7
Page 166
CONFIGURING POLLED DEVICES
Configuring a Device’s Communication Parameters
With IRL readers like the 9512, User-Defined Multi-Drop protocol is used to configure communication parameters. The parameters must correspond to the Multi-Drop protocol values listed in Table 6-2. See the device manual for specific instruction on entering parameters.
Table 6-2 User-Defined Multi-Drop Parameter Requirements
Parameter: Required Value: AFF ACK
NEG NAK
REQ ENQ
RES EOT
EOM1 ETX
EOM2 NUL (Disabled) SOM STX
LRC Must be enabled Timeout 100 msec Interchar 0 msec Turnaround 5 msec Terminal Mode Buffered or Transparent Stop Bits 1
Data Bits 7
Parity Even
(For the 951X family) XON = NUL (Disabled) XOFF = NUL (Disabled)
When you use User-Defined Multi-Drop protocol, you can redefine the IRL download parameters listed in Table 6-1. For more information about IRL refer to IRL 2.1 Programming Reference Manual, INTERMEC Part No. 048609. For specific information about configuring IRL characters see your reader manual.
Page 6-8 © 1987 INTERMEC Corporation
Page 167
User-Defined Mult!i-Drop Protocol
Setting Baud Rate
CAUTION
All devices must be set to the same baud rate as the controller. If all the devices are not operating at the same baud rate, data communication problems will result.
Baud rate may be 2400, 4800, 9600 or 19200 baud. The baud rates for each device must be the same as the controller baud rate setting and all other devices. See the manual for your device for instructions on setting baud rate.
Setting the Device Address
In User-Defined Multi-Drop protocol, a device address is assigned by entering the POL and SEL character corresponding to the desired Multi-Drop address. Table 6-3 lists the POL and SEL characters for each of the 32 device addresses. This table should be used to set addresses for devices that require selection of POL and SEL characters. To use the table, locate the device address, and then read across to find the POL and SEL characters that must be entered.
© 1987 INTERMEC Corporation Page 6-9
Page 168
CONFIGURING POLLED DEVICES
Table 6-3 Device Address and POL/SEL Characters for Multi-Drop Protocol
Device Address: Pol Character: Sel Character: ASCil HEX ASCII HEX A FS ic Gs 1D B RS 1E US 1F Cc Space 20 | 21 D . 22 # 23 E $ 24 % 25 F & 26 ' 27 G ( 28 ) 29 H * 2A + 2B I , 2c - 2D J . 2E / 2F K 0 30 1 31 L 2 32 3 33 M 4 34 5 35 N 6 36 7 37 .@) 8 38 9 39 P : 3A : 3B Q < 30 = 3D R > 3E ? 3F Ss @ 40 A 41 T B 42 Cc 43 U D 44 E 45 Vv F 46 G 47 WwW H 48 I 49 x J 4A K 4B Y L 4c M 4D Zz N 4E 1) 4F 0 P 50 Q 51 1 R 52 Ss 53 2 T 54 U 55 3 Vv 56 W 57 4 x 58 Y 59 5 Zz 5A [ 5B
Page 6-10 © 1987 INTERMEC Corporation
Page 169
Tracking Address Usage
TRACKING ADDRESS USAGE
Because there are two ways to set the device address, it is possible to give two devices the same address. For example, one device may be directly assigned address N, and another with User-Defined Multi-Drop protocol assigned 6 for POL and 7 for SEL (which corresponds to address N). If two devices have the same address, then both devices will try to drive the line at the same time, and communication problems will result.
To avoid assigning two devices the same address, it is advisable to keep a list of addresses already in use. Table 6-4 provides a sample form for recording addresses.
Each address should be marked off as itis assigned a device. It is helpful to know the identification number of each device so that if a device is removed later from the middle of the address range, another device can be placed at that address. If there are no device identification numbers, put a check in the Device Identification column or write down a description such as: 9510, Receiving; 9512, Shipping; 9512, Stores; etc.
Note: The controller will only poll and select addresses enabled on the Supervisory CRT Select Polled Devices screen.
© 1987 INTERMEC Corporation Page 6-11
Page 170
CONFIGURING POLLED DEVICES
Table 6-4 Device Address Form
Enabled/ Address: Disabled: ID Number: Date:
ARONAN<KTXS<CHMDOVOZErT AC -TOAMIOD>
Page 6-12 © 1987 INTERMEC Corporation