Page 141
Select Transmission Parameters
Responses to device specific polls are the same as for general polls. See Section 7, “Host to 9154 Communication,” for more information about device specific polling.
SEL: The SEL is used by the host to ask if the controller wants to send a message. SEL can be up to two ASCII characters.
The default value for SEL is ASCII BEL. If this value is satisfactory, press [CR]. SEL can be left blank, in which case the host can send data whenever it has data, without waiting for an AFF from the controller to confirm that it is ready to receive the data. To disable SEL enter [CNTL] [X] and press [CR].
AFF: AFF is the host response to a controller message indicating that the data is good.
The default value of AFF is ASCII ACK. AFF may be two ASCII characters.
NEG: NEG is the host response to a controller message and indicates that the data is bad and should be re-transmitted.
The default value of NEG is ASCII NAK. NEG can be up to two ASCII characters.
DLE: DLE is the character that precedes the control codes in host-to-controller communication to tell the controller that the character immediately after DLE is to be interpreted as data and not as a command.
The default for the host DLE is DLE (10H). The host DLE can be any single ASCII character.
SOM: The Host to Controller Start of Message is sent at the beginning of data messages to the controller. With certain protocols, this parameter can be disabled.
However, to maintain a secure data environment, it is recommended that this parameter not be disabled.
The default for the host SOM is STX (02H). The host SOM can be up to two ASCII characters.
© 1987 INTERMEC Corporation Page 5-29
Page 142
CONFIGURING THE CONTROLLER
EOM: The Host to Controller End of Message is sent at the end of data messages to the controller. This parameter must not be disabled or the controller will be unable to determine when or where received data ends.
The default for the From Host EOM is ETX (03H). The From Host EOM can be up to two ASCIl characters.
Record Separator: The Host Record Separator is sent after every individual data record that the host sends to the controller.
The default for the Host Record Separator is CR (ODH). It may be up to two ASCII characters.
Delay Timer: If the host sends a POL to the controller asking if it has data, the controller will respond to that POL in the time specified by the Delay timer. The numeric value that is entered in the Delay data field is multiplied by 10 msec to give the amount of time that the controller will respond in. For example, if the Delay value is 2, the controller will respond in 20 msec.
The default for the Delay timer is O msec. Any two digit number between 0 and 99 may be entered in the Delay Timer field.
Timeout: The Timeout parameter selects the amount of time the controller will wait, after sending a message to the host computer, before it expects a response. The Timeout is also used when receiving data from the host. The next character must be received within the Timeout specificied. The numeric value for this parameter is multiplied by one second to obtain the length of the timeout period. For example, if the timeout is "5", and the controller has transmitted data in response to a host POL, the controller will expect an AFF or NEG before five seconds have elapsed. If the timeout period is exceeded, the controller will register a timeout error, and be ready to re-transmit the data record at the next host POL.
Page 5-30 ©1987 INTERMEC Corporation
Page 143
Select Transmission Parameters
The default for the Timeout is 60 seconds. The Timeout can be any one or two digit number, 0 to 60.
XON/XOFF Enable: The XON/XOFF Handshake allows the controller and host to limit data transmissions if their receive buffers are full. The XON/XOFF handshake is especially useful if you are using an unsolicited communication protocol.
When the receiving unit's receive buffer is full, it will send XOFF (ASCII DC3) to the transmitter, telling it not to send any more data. After the receiving unit's receive buffer has room for more data, the receiving unit will send XON (ASCII DC1) to tell the transmitting unit that it is ready to accept data again.
The default for XON/XOFF is "N" for disabled. If this is satisfactory, press [CR]. To enable XON/XOFF, enter "Y" for Yes and press [CR].
LRC: The LRC is a message error check sent after the EOM character. The LRC is calculated as the exclusive OR of all the applicable characters in the following message block:
«<Header> <SOM> Data <EOR> <EOM>
If the header is enabled, all characters except the first character of the header are used.
If the header is disabled, all character except the first character of the SOM are used,
If neither the header or the SOM are used all of the characters in the message are used.
The default for the LRC is “N", for disabled. If this value is satisfactory, press [CR].
To enable LRC, enter [Y] for Yes and then press [CR].
© 1987 INTERMEC Corporation Page 5-31
Page 144
CONFIGURING THE CONTROLLER
Saving Transmission Parameters Review the transmission parametes displayed on the screen and change if necessary.
Then save the parameter values, re-initialize the controller, and return to the Master Menu by using one of the two following commands:
[CNTL] [7] Save the transmission parameters to RAM. [ESC] Save the transmission parameters to RAM and EEPROM.
See "Saving Parameters" earlier in this section for detailed information about saving parameters.
Page 5-32 ©1987 INTERMEC Corporation
Page 145
Select Clock Parameters
SELECT CLOCK PARAMETERS
The real time clock parameters are set using the Select Clock Parameters screen. To display the Select Clock Parameters screen enter [3], the press [CR]. The cursor will be positioned in the first parameter field, Date.
Select Clock Parameters HH:MM Set Real Time Clock: Date won ceeecevcccecee YY.MM.DD (YY.MM.DD) Time .ie cece ee eee eee ee HH.MM (HH. MM) Press CNTL~Y to Set Clock Time Append: Enable Time Append ...N (Y or N) Interval ..........66- 1 (0-99 minutes) Record Day Rollover .. N (Y or N) Time Broadcast: Enable Broadcast ..... N (Y or N) Interval (0-99 minutes) Preamble . Postamble Display Format ....... 24 (12 or 24) Include YY/MM/DD----- N (Y or N) Press CNTL-X to Cancel Line Press CNTL~T Return to Task Opcions Press ESC to Update EEPROM N
Three types of real time clock parameters are available on this screen: 1. Set Time and Date
2. Time Append 3. Time Broadcast
© 1987 INTERMEC Corporation Page 5-33
Page 146
CONFIGURING THE CONTROLLER
Set Time and Date is used to update the controller real time clock.
Time Append specifies if and how to add time to the data records received from polled devices.
Time Broadcast specifies if and how time should be broadcast to the polled devices.
Both Time Append and Time Broadcast can be disabled. If they are disabled you will not need to change the other field associated with them.
The host computer can configure all of the controller's time parameters with host commands. For more information about computer configuration of the controller, see Section 7, “Host to 9154 Communication.”
Note: If the host happens to update a clock parameter while this screen is displayed on the Supervisory CAT, the screen will be redisplayed so that you can see the change.
Set Real Time Clock
The two Set Real Time Clock parameters are used to change the time on the controller's internal real time clock. The current time is displayed in the upper right corner of the Supervisory CRT screen, and will be used for any Time Append or Time Broadcast parameters that are enabled.
Date: To update the controller's real time clock enter a new date in the following format:
YY.MM.DD
The following field restrictions apply:
Field: Field Name: Valid Entry: MM Month 1-12
DD Day 1-31
YY Year 00-99
Page 5-34 ©1987 INTERMEC Corporation
Page 147
Select Clock Parameters
Numbers are the only acceptable entries. if a invalid entry is made in the field, the CRT will beep and the cursor will stay in the field. The field delimiter (.) between YY and MM, and MM and DD must be entered in its proper locations or the Supervisory CRT will not accept the entry.
Time: The current real time clock time is displayed in the upper right corner of the screen in the following format:
HH.MM (HH = hour, MM = minutes).
To update the time on the controller's real time clock, enter a new time in the hours and minutes format. The following field restrictions apply:
Field: Field Name: Valid Entry: HH Hours 0-23 (24-hour) MM Minutes 0-59
Numbers are the only allowable entries in either the Hours or Minutes field. Ifa invalid entry is made in either part of the field, the CRT will beep and the cursor will be re-positioned at ithe start of the field. The field delimiter between Hours and Minutes (.) must be entered, or the Supervisory CRT will beep and not accept the input.
Updating the Real Time Clock: After setting the time, you can update the controller real time clock by entering [CNTL] [Y]. Once the real time clock has been updated, all time functions will use the new time.
Time Append Parameters The three Time Append parameters allow time to be appended to the records received from the polled devices at a specified time interval.
Do not enable time append on both the controller and the polled devices. If time is enabled on both, problems will occur at the host application when a record is received with two time stamps.
© 1987 INTERMEC Corporation Page 5-35
Page 148
CONFIGURING THE CONTROLLER
To add time to every record, enable Time Append and leave the Time Append Interval as zero. The controller will append time to every record in the following format:
data>DD:HH:MM <EOR>
To add time at regular intervals, enable Time Append and change the Time Append Interval to a non-zero value. A time record will be added to data waiting to be sent to the host at the specified time interval. The format is:
>DD:HH:MM <EOR>
Enable Time Append: Time append adds the time to records received from the devices at the time interval specified by the time interval parameter. Two options are available, "Y" for Yes, to enable time append, and “N" for No, to disable time append. The default is "N" for disabled.
If you will need time append enabled, press [CR]. To enable time append, enter [Y] and press [CR].
Interval: The interval is the minimum length of the time between adding time records to the information in the polled device data buffer. The time interval can be up to two digits (0-99) and represents minutes.
For example, if the time interval is one minute, and an hour passes before the next data record is received from the polled devices, the polled device data buffer is not given a time statement every minute. Instead, the time is added only when a data record is added for transmission, regardless of how many time intervals have passed.
In situations where the controller system is sparingly used for periods of time (for example, during the lunch hour), the communication between the controller and the host computer would consist primarily of time messages. Instead, when a record is finally received, a time message with the time of the last minute will be added.
Page 5-36 ©1987 INTERMEC Corporation
Page 149
Select Clock Parameters
The example that follows shows the data as it would appear in the Review Data Buffer screen explained in Section 8, “CRT Control of 9154 Communication.”
A5PCB2223-45 >02:04:14 A3PCB2224-44 >02:04:15
If a time interval of 0 is satisfactory, press [CR]. This means that a time message will be appended to every data record.
To set a new time interval, enter a number between 0 and 99 to represent minutes and press [CR].
Record Day Rollover: The Record Day Rollover puts a time stamp into the polled device buffer at 12:00 midnight. This guarantees that the host computer program will have data to extract from the controller when its program starts in the morning.
The default value for Record Day Rollover is N for No. If having the Record Day Rollover disabled is satisfactory, press [CR].
To enable Record Day Rollover, enter [Y] and press [CR].
Time Broadcast The five time broadcast parameters allow the current time to be broadcast to the polled devices, as displayed in the upper right corner of the Supervisory CRT screen. The format of the time broadcast depends on how the time broadcast parameters are configured. The format of the time is hour, minute in either military or standard 12-hour time format. Any combination of the Preamble, YY/MM/DD, and Postamble can be disabled.
© 1987 INTERMEC Corporation Page 5-37
Page 150
CONFIGURING THE CONTROLLER lf Time Broadcast is enabled, time will be sent to the polled devices in the following format:
<preamble>HH:MM<postambie> If Include YY/MM/DD is specified, time will be sent in the following format:
<preamble > YY/MM/DD:HH:MM < postamble >
If time is going to be displayed on the polled devices, time broadcast must be enabled. If no time broadcast is desired, and the value for Enable Time Broadcast is “N", then skip the whole Time Broadcast section of the screen.
Enable Time Broadcast: This parameter allows time, in the format determined by the other time broadcast parameters, to be transmitted to the polled devices.
The default setting is "N" for Time Broadcast disabled. If this is satisfactory, press [CR].
To enable the broadcast of time, enter [Y] then [CR].
Interval: The time broadcast interval parameter specifies how often the time display on the polled devices will be updated. The range of acceptable inputs is any two digits from 0 to 99. The parameter value specifies minutes.
The default parameter is "1," indicating that the time will be updated every minute. If"1" is satisfactory, press [CR].
To change the time interval, enter a new number for the minutes desired, and then press [CR]. If set to "0", the time will not be broadcast.
Preamble: The preamble parameter allows a short message to be placed before the time broadcast. It can be one to five ASCII characters long or be left blank to signify that it is disabled. {f a message longer than five characters is entered, the Supervisory CRT will beep, and the message will be truncated to five characters.
The default message for Preamble is the single ASCil character HT. If this is satisfactory, press [CR].
Page 5-38 ©1987 INTERMEC Corporation