Page 171
Norand R Utilities Program
APPENDIX B
Suboption 1 MODEM TYPE If you select this suboption, a drop-down list appears with supported modem types. Press the Y or B keys to scroll through the list, then press the [ENT] button to enter. "
If you select drop-option OTHER EXTERNAL or OTHER INTERNAL, the Modem Init String pop-up menu appears: MODEM INIT STRING ATE0V0Q0&M0&S1&C1& D0&R/QX0L1 [F2]TEST STRING [ENT]OK [--]QUIT a. Enter the initialization string of the modem you are using. Refer to your modem’s reference manual for information. " NOTE:
Use A and " keys on numeric keyboards to scroll the alphanumeric character set.
" NOTE:
If you leave this menu blank, a string is not saved.
b. Press the [ENT] key to enter the string or press the [--] key to exit this pop-up menu.
6400 Hand-Held Computer User’s Guide
B-21
Page 172
Norand R Utilities Program
" NOTE:
APPENDIX B
Testing the modem initialization string is optional.
To test the modem string, do the following: a. Press the [F2] key. The computer replies with “PLEASE WAIT” and tests the string: "
MODEM INIT STRING ATE0V0Q0&M0&S1&C1& D0&R/QX0L1 PLEASE WAIT . . . [F2]TEST STRING [ENT]OK [--]QUIT
Momentarily, the computer displays the modem’s response: MODEM INIT STRING ATE0V0Q0&M0&S1&C1& D0&R/QX0L1 RESULT:
97
[F2]TEST STRING [ENT]OK [--]QUIT
" NOTE:
Zero indicates the modem was successfully configured. Any other value indicates an error. See page B-12 for a list of modem errors defined by this program. If this is a NORAND modem, contact the Norand Customer Response Center at 1-800-221-9236. If this is not a NORAND modem, contact your modem supplier.
b. Press the [ENT] key to update the modem initialization string. The computer returns to the Modem Parameters pop-up menu with OTHER EXTERNAL or OTHER INTERNAL assigned.
B-22
6400 Hand-Held Computer User’s Guide
Page 173
Norand R Utilities Program
APPENDIX B
Suboption 2 PROTOCOL If you select this suboption, a drop-down list of various protocols appears: 1. TTY 2. YMODEM
Press the number of a protocol, or press the Y or B keys to scroll through the list, then press the [ENT] key to enter. The computer returns to the Modem Parameters pop-up menu with the selected protocol assigned. Press the [--] key to exit this drop-down list.
Suboption 3 BPS RATE If you select this suboption, the BPS Rate drop-down list appears with various bits per second (BPS) rates: 1. 2. 3. 4. 5. 6. 7. 8.
1200 2400 4800 9600 19200 38400 57600 115200
Press the number of a BPS rate, or press the Y or B keys to scroll through the list, then press the [ENT] key to enter. The computer returns to the Modem Parameters pop-up menu with the selected BPS rate assigned. Press the [--] key to exit this drop-down list.
6400 Hand-Held Computer User’s Guide
B-23
Page 174
Norand R Utilities Program
APPENDIX B
Suboption 4 DATA FORMAT If you select this suboption, the Data Format drop-down list appears: 1. 8N1 2. 7E1
Press the number of a data format, or press the Y or B keys to scroll through the list, then press the [ENT] key to enter. The computer returns to the Modem Parameters popup menu with the selected data format assigned. Press the [--] key to exit this drop-down list.
Suboption 5 AUTO ANSWER This suboption is not supported at this time.
Option 5 PHONE NUMBER If you select this option, the Phone Number pop-up menu appears: PHONE NUMBER 9...13193693282 [ . ]DIALING PAUSE [ENT]OK [--]QUIT
Enter up to 16 characters. Use the [mSP] key to backspace; use the [CLR] to reset to the previous phone number, and press [.] to insert a dialing pause command (“,”). Press the [ENT] key to save the new phone number and return to the Communications Settings menu. Press the [--] key to exit this pop-up menu. B-24
6400 Hand-Held Computer User’s Guide
Page 175
Norand R Utilities Program
APPENDIX B
Option 6 ADVANCED UTILITIES If you select this option, the Advanced Utilities menu appears: NORAND UTILITIES ADVANCED UTILITIES 1. 2. 3. 4. 5. 6. 7.
SET DATE/TIME BATTERY STATUS FORMAT DRIVE D FORMAT RAM CARD SET BOOT DRIVE ABOUT SET KEY CLICK
Press the number of an advanced utility option, or press the Y or B keys to scroll through the list, then press the [ENT] key to enter.
6400 Hand-Held Computer User’s Guide
B-25
Page 176
Norand R Utilities Program
APPENDIX B
Suboption 1 SET DATE/TIME If you select this suboption, the Set Date/Time pop-up menu appears: SET DATE/TIME DATE: TIME:
01/20/80 23:12:04 [--]QUIT
Enter numbers for the month, day, year (1980--2079), hour, minute, and second (up to 23:59:59). Press the [ENT] key after each entry. An incorrect entry causes the computer to default to the initial number. Press the [--] key to exit this pop-up menu.
Suboption 2 BATTERY STATUS Use this suboption to check battery status. The Battery Status screen appears when you select this suboption: BATTERY STATUS MAIN PACK E TYPE
F CHARGEABLE
CAPACITY VOLTAGE
80% 7.8 OK
BACKUP VOLTAGE
7.2 OK
LCD TEMP
23 C [--]QUIT
B-26
6400 Hand-Held Computer User’s Guide
Page 177
Norand R Utilities Program
APPENDIX B
"
"
"
" "
"
The battery fuel gauge displays the battery capacity level in black from left to right. The capacity range that will display is 5--100%. If the capacity is less than 5% no operation of your computer will occur until you have recharged the battery to obtain at least 10% of its capacity. Battery type is chargeable for rechargeable battery pack. The voltage range is 6--8.4 volts. The backup battery voltage will range from 6--11 volts. Below 7 volts indicates a mostely discharged backup battery. Between 7--8 volts the backup battery could be in any charged state. Between 8--11 volts is a mostly charged backup battery and good for at least 100 hours of backup support. LCD temperature displays in celcius and measures the outside temperature of the display. Temperatures less than -4_F (-20_C) or greater than +122_F (+50_C) can cause faulty display operation.
6400 Hand-Held Computer User’s Guide
B-27
Page 178
Norand R Utilities Program
APPENDIX B
Suboption 3 FORMAT DRIVE D If you select this suboption, the Format RAM Drive pop-up menu appears: FORMAT DRIVE D
[ENT]OK
0MB 0KB [--]QUIT
Enter the total MB and KB for the RAM drive. " NOTE:
A zero in both fields deletes the RAM drive.
Press the [ENT] key after each entry. A pop-up verification appears: FORMAT DRIVE D ALL DATA ON EXISTING RAM DRIVE WILL BE DESTROYED! OK TO CONTINUE? [ENT]OK
[--]QUIT
Press the [ENT] key to continue. Press the [--] key to exit the menu.
B-28
6400 Hand-Held Computer User’s Guide
Page 179
Norand R Utilities Program
APPENDIX B
Suboption 5 SET BOOT DRIVE If you select this suboption, the Set Boot Drive pop-up menu appears: SET BOOT DRIVE 1. A: 2. B: 3. C:
4. D: 5. E: 6. F:
[--]QUIT
" NOTE:
The current default drive is highlighted in this menu.
Press the number of a boot drive, or press the Y or B keys to scroll through the list, then press the [ENT] key to enter. The computer returns to the Advanced Utilities menu. Press the [--] key to exit this pop-up menu.
Suboption 6 ABOUT If you select this suboption, the version of keyboard controller and BIOS displays.
Press the [--] key to exit this pop-up menu.
6400 Hand-Held Computer User’s Guide
B-29
Page 180
Norand R Utilities Program
APPENDIX B
Suboption 7 SET KEY CLICK If you select this suboption, the Set Key Click pop-up menu appears: SET KEY CLICK FREQUENCY Hz DURATION [ENT]OK
2051 100 mS [--]QUIT
Press the ▲ or ▼ keys to select the frequency of the key click or the length of time to hear the key click. Enter the new frequency and or the new duration settings. Press the [ENT] key after each entry. A pop-up verification appears. Press the [ENT] key to continue. Press the [--] key to exit the menu.