Page 161

Norand R Utilities Program

APPENDIX B

The three digit number (“289”) indicates the specific protocol error. These error codes apply when COMM SETTINGS is set to NPCP RS-485 or NPCP RS-232: "

“0” “1” “6” “11”

" NOTE:

No error MININET.EXE not installed User aborted communications by pressing [--] Invalid parameter specified in control file

The following values indicate an error returned by MININET.EXE. 100 is added to the error returned by MININET.EXE to avoid conflict with other defined errors.

“101” “103” “105” “106” “108” “109” “110” “111” “113” “114” “115” “117” “118” “119” “120” “121” “122” “123” “124” “125” “126” “133” “134” “135” “136”

Illegal buffer length Invalid command Command timed out Message incomplete Illegal local session number No resource available Session closed Command canceled Duplicate name in local name table Name table is full Name is deregistered, command complete Local session table full Session open rejected Invalid name number No answer Name not found Name in use on remote adapter Name deleted Session ended abnormally Name conflict Incompatible remote device Network interface is busy Too many commands outstanding Invalid LAN adapter number Command completed while cancel occurring 6400 Hand-Held Computer User’s Guide

B-11

Page 162

Norand R Utilities Program

APPENDIX B

“138” Command not valid to cancel “164”--“179” Unusual network condition “180”--“354” Adapter malfunction These error codes apply when COMM SETTINGS is set to MODEM/DIRECT and PROTOCOL is set to TTY: “0” No error “6” [--] key pressed, aborting communications “11” Invalid parameter specified in control file “23” End of transmission “101” Line lost “102” Parity error “103” Character gap too long “104” Data loss “105” Excessive NAKs (no acknowledgements) “106” Block count error “107” Block check error “108” Block framing error “109” Control character error “2xx” Modem error “xx” Hayes response code, or code defined by program: “86” Error sending command to modem “87” Expected numeric response not numeric “88” Invalid response format “89” No significant response from modem “97” COM port disabled by system due to low battery or removal of PC card modem. “98” Unrecognized English response “99” Memory allocation error

B-12

6400 Hand-Held Computer User’s Guide

Page 163

Norand R Utilities Program

APPENDIX B

These error codes apply when COMM SETTINGS is set to NOVELL NETWARE: "

“0” “6”

No error User aborted communications by pressing [--] key. “100” Connection to host failed. Verify network connection, verify that PENKEY login name exists on host. “101” Could not access include file. Verify existence of include file on host. “102” Could not allocate needed memory.

These error codes apply when COMM SETTINGS is set to NRINET: "

“0” “6” “800” “801” “802” “803” “804” “806” “807” “808” “809” “810”

No error User aborted communications by pressing [--] key. PC TCP/IP kernel is missing. Invalid client IP address. Make sure the entry for CLIENT IP ADDRESS is correct, or make sure the DHCP server is running. Invalid Service or Service Type, or invalid port number. Invalid host name or IP Address. Make sure the entry for SERVER NAME is correct, and that the server is running. Could not create socket. Check all cables and network connections. Block sent was incomplete or block received was incomplete. Client and server negotiation failed. Server specified an unsupported block size. Invalid buffer pointer. All server connections are already in use. Try again later.

6400 Hand-Held Computer User’s Guide

B-13

Page 164

Norand R Utilities Program

APPENDIX B

“811”

Timeout while sending data. Connection to remote machine dropped. Make sure the host is still running, and check all cables and network connections. “812” Timeout while receiving data. Connection to remote machine dropped. Make sure the host is still running, and check all cables and network connections. “935” Operation would block. “939” Destination address required. “940” Message too long. “948” Address already in use. “950” Network is down. “951” Network is unreachable. “952” Network dropped connection or reset. “954” Connection reset by peer. “955” No buffer space available. “960” Connection timed out. “961” Connection refused. “962” Too many levels of symbolic links. “963” File name is too long. “964” Host is down. “965” Host is unreachable. “966” Directory not empty. These error codes apply when COMM SETTINGS is set to TFTP: "

“0” “1” “6” “201” “202” “203” “204” “205” “206” “207”

B-14

No error. TCP/IP kernel is not loaded. User aborted communications by pressing [--] key. TFTP.EXE failed. TFTP.EXE not found. Unknown server. Remote file name is invalid. Local file name is invalid. File not found on server. Timeout.

6400 Hand-Held Computer User’s Guide

Page 165

Norand R Utilities Program

APPENDIX B

Option 2 COMM SETTING If you select this option, the Communications Settings dropdown list appears: 1. NETWORK. . . 2. MODEM/DIRECT 3. ACCESSORY CARD 4. HANDHELD 5. INTERSERVER

Press the number of a communications settings, or press the Y or B keys to scroll through the list, then press the [YES] key to enter.

Suboption 1 NETWORK If you select this suboption, a drop-down list appears with various networks: 1. NETWORK. . . 1. NPCP RS485 2. NPCP RS232 3. NRINET 4. TCP/IP BOOTP 5. NOVELL NETWARE

Press the number of a network or press the Y or B keys to scroll through the list, then press the [ENT] key to enter. The computer returns to the Communications Menu with the selected network assigned to Option 2. COMM SETTING. See a sample menu on page B-6. Press the [--] key to exit this drop-down list. The computer takes you to the Communications Menu.

6400 Hand-Held Computer User’s Guide

B-15

Page 166

Norand R Utilities Program

APPENDIX B

Suboption 2 MODEM/DIRECT If you select this suboption, the computer returns to the Communications Menu with the MODEM/DIRECT option assigned to Option 2. COMM SETTING: NORAND UTILITIES COMMUNICATIONS 1. BEGIN COMM SESSION 2. COMM SETTING MODEM/DIRECT 3. UNIT ID 4. MODEM PARAMETERS MODEM TYPE NM2400/NM2400A PROTOCOLBPS FMT TTY 2400 8N1 AUTO ANSWER NO 5. PHONE NUMBER 9...131369282

6. ADVANCED UTILITIES

B-16

6400 Hand-Held Computer User’s Guide

Page 167

Norand R Utilities Program

APPENDIX B

Suboption 3 ACCESSORY CARD Suboption 5 INTERSERVER If you select either of these suboptions, the computer returns to the Communications Menu with ACCESSORY CARD or INTERSERVER assigned to Option 2. COMM SETTING. NORAND UTILITIES COMMUNICATIONS 1. BEGIN COMM SESSION 2. COMM SETTING ACCESSORY CARD 3. UNIT ID

6. ADVANCED UTILITIES

Suboption 4 HANDHELD

6400 Hand-Held Computer User’s Guide

B-17

Page 168

Norand R Utilities Program

APPENDIX B

Option 3 UNIT ID If you select this option, the Change Unit ID pop-up menu appears: CHANGE UNIT ID UNIT ID 2233233 WORKGROUP 6200IPL [F4]RESET FACTORY [--]QUIT

Enter up to eight characters to change the Unit ID. Use the [mSP] key to backspace and use the [CLR] to restore the previous ID. Press the [ENT] key to save the new ID and return to the Communications Settings menu. Press the [F4] key to reset the ID to factory default. Press [--] to exit this pop-up menu.

Option 4 NETWORK PARAMETERS Network Parameters appears as Option 4 when Option 2. COMM SETTINGS is set to one of these three NETWORK options: NRINET, TFTP, or NOVELL NETWARE.

B-18

6400 Hand-Held Computer User’s Guide

Page 169

Norand R Utilities Program

APPENDIX B

NETWORK PARAMETERS with NRINET NETWORK PARAMETERS with TFTP If you select this option and Option 2. COMM SETTINGS is set to NRINET or TFTP, this Network Parameters popup menu appears: NETWORK PARAMETERS SERVER NAME SERVER IP ADDRESS 0. 0. 0. CLIENT IP ADDRESS 0. 0. 0. RTR 0. 0. 0. SUBNET MASK 0. 0. 0.

0 0 0 0

[--]QUIT

If you have an alphanumeric keyboard, press the characters to the host name, then press the [ENT] key to save the entry and move to the next field. If you have a numeric keyboard, use the A and " keys to scroll back and forth through the given set of alphanumeric characters. After a character is selected, press the [ENT] key to enter that character. Press [ENT] again to move to the next field. Press the Y or B keys to move between fields. Press [ENT] to save the entries and exit the Network Parameters menu. Press the [--] key to exit without saving the entries.

6400 Hand-Held Computer User’s Guide

B-19

Page 170

Norand R Utilities Program

APPENDIX B

NETWORK PARAMETERS with NOVELL NETWARE If you select this option and Option 2. COMM SETTINGS is set to NOVELL NETWARE, this frame type drop-down list appears: 1. 802.2 2. ETHERNET II 3. 802.3 RAW 4. 802.2 W/ SNAP

Press the number of a frame type, or press the Y or B keys to scroll through the list and press the [ENT] key to enter. Press the [--] key to exit this drop-down list without changing the frame type.

Option 4 MODEM PARAMETERS Modem Parameters appears as Option 4 when Option 2. COMM SETTINGS is set to MODEM/DIRECT. If you select this option, the Modem Parameters pop-up menu appears. MODEM PARAMETERS 1. MODEM TYPE NM2400/NM2400A 2. PROTOCOL TTY 3. BPS RATE 2400 4. DATA FORMAT 8N1 5. AUTO ANSWER -[--]DONE

Press the number of a modem parameters option, or press the Y or B keys to scroll through the list, then press the [ENT] button to enter. B-20

6400 Hand-Held Computer User’s Guide