For the Intermec 6400

Page 221

Configuration Command Reference

7

Display Backlight Timeout (continued) Or:

To set the backlight timeout: 1. Scan this bar code: Enter Accumulate Mode / Set Backlight Timeout

*+/$+DF* *+/$+DF*

2. Scan a numeric value (one or two digits) for data from these bar codes:

*0*

*1*

*2*

*3*

*0*

*2*

*4* *4*

*6* *6*

*8* *8*

*1*

*3*

*5*

*5*

*7*

*7*

*9*

*9*

3. Scan this bar code: Exit Accumulate Mode

*-/* *-/*

PSK Example:

im_command (“$+DF5”,5); will set the backlight timeout to 5 minutes.

7-19

Page 222

6400 PSK Reference Manual

Display Font Type Purpose:

Selects the type or size of font that is used on the 6400 screen. You can set a regular size font (6x9), a font with double-height characters (6x18), or a font with double-width and double-height characters (12x18).

Syntax:

DTdata Acceptable values for data are: 0 1 2

Default: Scan:

6 pixels by 9 pixels (6x9) font 6 pixels wide by 18 pixels high (6x18) font 12 pixels wide by 18 pixels high (12x18) font

6x9 One of these bar codes: Set Display Font Type to 6x9

Set Display Font Type to 6x18

*$+DT0*

*$+DT1*

*$+DT0*

Set Display Font Type to 12x18

*$+DT2* *$+DT2*

PSK Example:

im_command (“$+DT2”,5); will set the display font type to 12x18.

7-20

*$+DT1*

Page 223

Configuration Command Reference

7

End of Message (EOM) Purpose:

Attaches an EOM to the end of a data block to indicate the end of data transmission to and from a 6400. When EOM is disabled, the 6400 communicates in Character mode. When EOM is enabled, the 6400 communicates in Frame mode. You must configure a value for EOM before you can set these other serial communications commands: • • • •

Configuration Commands Via Serial Port Handshake LRC Start of Message (SOM)

If EOM is disabled or not set, you need to disable these serial communications commands. EOM cannot equal the same value that is set for SOM. You cannot set EOM to any of these values: • • • • • Syntax:

AFF (ACK) DLE NEG (NAK) Poll RES (EOT)

• • • •

REQ (ENQ) SEL XOFF XON

PFdata Acceptable values for data are one or two ASCII characters.

Default:

\x03 (hexadecimal value for ETX)

Scan:

To disable EOM, scan this bar code: Disable EOM

*$+PF* *$+PF*

Or:

To set EOM to one or two ASCII characters: 1. Scan this bar code: Enter Accumulate Mode / Set EOM

*+/$+PF* *+/$+PF*

7-21

Page 224

6400 PSK Reference Manual

End of Message (EOM) (continued) 2. Scan one or two bar codes for data from the “Full ASCII Table” in Appendix C. 3. Scan this bar code: Exit Accumulate Mode

*-/* *-/*

PSK Example:

im_command (“$+PF\x03”,5); will set EOM for the serial port to ETX.

7-22

Page 225

Configuration Command Reference

7

Interleaved 2 of 5 Purpose:

Enables or disables decoding of Interleaved 2 of 5 (I 2 of 5) symbology. I 2 of 5 is a high-density, self-checking, continuous numeric symbology. It is mainly used in inventory distribution and the automobile industry.

Syntax:

CAdata Acceptable values for data are: 0 2-30 98

Disabled Fixed length (even number only) Case Code (6 or 14 characters) with a check digit

Variable length is not supported. Default: Scan:

Disabled One of these bar codes: Disable Interleaved 2 of 5

*$+CA0* *$+CA0*

Enable Interleaved 2 of 5, Case Code (6 or 14)

*$+CA98* *$+CA98*

Or:

To set Interleaved 2 of 5 to a fixed length: 1. Scan this bar code: Enter Accumulate Mode / Set Fixed Length

*+/$+CA* *+/$+CA*

2. Scan a numeric value for data from these bar codes. (Use even numbers 2-30 only.)

*0*

*1*

*2*

*3*

*0*

*2*

*1*

*3*

7-23

Page 226

6400 PSK Reference Manual

Interleaved 2 of 5 (continued)

*4* *4*

*6*

*6*

*8* *8*

3. Scan this bar code to exit: Exit Accumulate Mode

*-/* *-/*

PSK Example:

im_command (“$+CA16”,6); will enable I 2 of 5 with a fixed length of 16 characters.

PSK Example:

im_command (“$+CA98”,6); will enable I 2 of 5 Case Code (either 6 or 14 characters).

Keypad Clicker Purpose:

Enables or disables the keypad clicks. The 6400 sounds a click each time you press a key or decode a row of a two-dimensional symbology.

Syntax:

KCdata Acceptable values for data are: 0 1

Default: Scan:

Disable keypad clicker Enable keypad clicker

Disabled One of these bar codes: Disable Keypad Clicker

Enable Keypad Clicker

*$+KC0*

*$+KC1*

*$+KC0*

PSK Example:

im_command (“$+KC1”,5); will enable the keypad clicker.

7-24

*$+KC1*

Page 227

Configuration Command Reference

7

MSI Purpose:

Enables or disables decoding of MSI symbology. MSI code is similar to Plessey code. MSI code includes a start pattern, data characters, a check digit, and a stop pattern. The check digit is always transmitted.

Syntax:

CNdata Acceptable values for data are exactly two digits, corresponding to: First digit: Second digit:

Default: Scan:

0 1, 2, or 3 0 or 1

Disabled Enabled - 1 modulus 10 check digit Ignored

Disabled To disable MSI, scan this bar code: Disable MSI

*$+CN01* *$+CN01*

To enable MSI and transmit a check digit, scan this bar code: MSI With 1 Modulus 10 Check Digit, Transmit Check Digit

*$+CN21* *$+CN21*

PSK Example:

im_command (“$+CN21”,6); will enable MSI.

7-25

Page 228

6400 PSK Reference Manual

Parity Purpose:

Sets the parity for the serial port. The 6400 uses parity for error checking in data transmissions.

Syntax:

IBdata Acceptable values for data are: 0 1 2

Default: Scan:

No parity Even parity Odd parity

Even parity One of these bar codes: No Parity

Even Parity

*$+IB0*

*$+IB1*

*$+IB0*

*$+IB1*

Odd Parity

*$+IB2*

*$+IB2*

PSK Example:

im_command (“$+IB2”,5); will set parity to odd.

Postamble Purpose:

Sets the postamble that is appended to any data you scan with the 6400. Common postambles include cursor controls such as tabs or carriage return line feeds.

Syntax:

AEdata Acceptable values for data are up to 25 ASCII characters. If you enter the AE command without data, the postamble is disabled. If you are entering quotation marks as data or grouping configuration commands, you need to enclose the data within quotation marks (see the example). Note: To scan a bar code label that includes quotes, you must configure the 6400 to use Code 39 in Full ASCII mode. For help, see “Code 39” earlier in this chapter.

7-26

Page 229

Configuration Command Reference

7

Postamble (continued) Default: Scan:

Disabled (no characters) To disable the postamble, scan this bar code: Disable Postamble

*$+AE* *$+AE*

Or:

To set the postamble to an ASCII character string: 1. Scan this bar code: Enter Accumulate Mode / Set Postamble

*+/$+AE* *+/$+AE*

2. Scan a value for data from the “Full ASCII Table” in Appendix C. The postamble can be from 1 to 25 characters. 3. Scan this bar code: Exit Accumulate Mode

*-/* *-/*

Example:

You want to set a postamble that includes quotation marks. Enter the postamble by scanning this full ASCII bar code label: Set Postamble to “B”

*/D/KAE/B/B/BB/B/B/B* *$+AE"""B"""*

You must enclose the data within quotation marks and precede each quotation mark with another quotation mark so that the quotation marks are not treated as the end of the data. PSK Example:

im_command (“$+AEB”,5); will set the postamble to B.

7-27

Page 230

6400 PSK Reference Manual

Preamble Purpose:

Sets the preamble that precedes any data you scan with the 6400. Common preambles include a data location number or an operator number. Note: You can set the preamble to use characters from the extended ASCII character set. However, you cannot scan in extended ASCII characters in the Preamble command.

Syntax:

ADdata Acceptable values for data are up to 25 ASCII characters. When you enter the AD command without data, the preamble is disabled. If you are entering quotation marks as data or grouping configuration commands, you need to enclose the data within quotation marks (see the example). Note: To scan a bar code label that includes quotes, you must configure the 6400 to use Code 39 in Full ASCII mode. For help, see “Code 39” earlier in this chapter.

Default: Scan:

Disabled (no characters) To disable the preamble, scan this bar code: Disable Preamble

*$+AD* *$+AD*

Or:

To set the preamble to an ASCII character string: 1. Scan this bar code: Enter Accumulate Mode / Set Preamble

*+/$+AD* *+/$+AD*

2. Scan a value for data from the “Full ASCII Table” in Appendix C. The preamble can be from 1 to 25 characters. 3. Scan this bar code: Exit Accumulate Mode

*-/* *-/*

7-28