Page 231

Configuration Command Reference

7

Preamble (continued) Example:

You want to set a preamble that includes quotation marks. Enter the preamble by scanning this full ASCII bar code label: Set Preamble to “B”

*/D/KAD/B/B/BB/B/B/B* *$+AD"""B"""*

You must enclose the data within quotation marks and precede each quotation mark with another quotation mark so that the quotation marks are not treated as the end of the data. PSK Example:

im_command (“$+ADB”,5); will set the preamble to B.

Start of Message (SOM) Purpose:

SOM is the first character in a message sent to or received from the host computer through the 6400’s serial port. SOM cannot equal the same value that is set for EOM. You cannot set SOM to any of these values: • • • • •

AFF (ACK) DLE NEG (NAK) Poll RES (EOT)

• • • •

REQ (ENQ) SEL XOFF XON

Note: Before you can enable SOM, you must configure the EOM command.

Syntax:

PEdata An acceptable value for data is any ASCII character. No data will disable SOM.

Default:

\x02 (hexadecimal value for STX)

Scan:

To disable SOM, scan this bar code: Disable SOM

*$+PE* *$+PE*

7-29

Page 232

6400 PSK Reference Manual

Start of Message (SOM) (continued) Or:

To set SOM to an ASCII character: 1. Scan this bar code: Enter Accumulate Mode / Set SOM

*+/$+PE* *+/$+PE*

2. Scan a bar code for data from the “Full ASCII Table” in Appendix C. 3. Scan this bar code: Exit Accumulate Mode

*-/* *-/*

PSK Example:

im_command (“$+PE\x02”,5); will set SOM to STX.

Stop Bits Purpose:

Sets the number of stop bits on the serial port.

Syntax:

ICdata Acceptable values for data are: 1 2

Default: Scan:

1 stop bit 2 stop bits

1 stop bit One of these bar codes: 1 Stop Bit

2 Stop Bits

*$+IC1*

*$+IC2*

*$+IC1*

PSK Example:

im_command (“$+IC2”,5); will set serial port to 2 stop bits.

7-30

*$+IC2*

Page 233

Configuration Command Reference

7

Time and Date Purpose:

Sets the time and date on the 6400.

Syntax:

DBdata Acceptable values for data are 12 digits corresponding to: yy mm dd hh mm ss

Default: Scan:

00-99 01-12 01-31 01-12 00-59 00-59

Year Month of the year Day of the month Hour Minutes Seconds

920101120000 To set the time and date: 1. Scan this bar code: Enter Accumulate Mode / Set Time and Date

*+/$+DB* *+/$+DB*

2. Scan a numeric value for each digit from these bar codes:

*0*

*1*

*2*

*3*

*0*

*2*

*4* *4*

*6* *6*

*8* *8*

*1*

*3*

*5*

*5*

*7*

*7*

*9*

*9*

7-31

Page 234

6400 PSK Reference Manual

Time and Date (continued) 3. Scan this bar code: Exit Accumulate Mode

*-/* *-/*

PSK Example:

im_command (“$+DB011225010101”,16); will set the date to December 25, 2001.

Time in Seconds Purpose:

If you enable the Append Time command, you can enable the Time in Seconds command to append the seconds to each transaction transmitted from the 6400. To append the time in hours and minutes, disable the Time in Seconds command.

Syntax:

DAdata Acceptable values for data are: 0 1

Default: Scan:

Disabled Enabled

Disabled One of these bar codes: Disable Time in Seconds

*$+DA0* *$+DA0*

Enable Time in Seconds

*$+DA1* *$+DA1*

PSK Example:

im_command (“$+DA1”,5); will enable time in seconds.

7-32

Page 235

Configuration Command Reference

7

UPC/EAN Purpose:

Enables or disables decoding of UPC-A, UPC-E, EAN-8 and EAN-13. When enabled, supplementals are auto-detected and are transmitted. UPC Preamble of System and Country Codes are detected and transmitted. Check digits for UPC-A and UPC-E are detected and transmitted. The 6 digits of UPC-E are expanded into a UPC-A 12-digit code.

Syntax:

CEdata Acceptable values for data are four, five, six, or seven digits. The first digit must be 0, 1, or 2. The other digits must be 0 or 1. 0000 0111

Default: Note:

Disabled Enabled

Enabled If any of the first four digits are non-zero (and in the valid range), UPC/EAN decoding is enabled. If any of the last three digits is included, they are ignored. All digits must be in the valid ranges. Otherwise, the command is invalid and has no effect. For example, $+CE2010010 enables decoding, but $+CE012111 is invalid because the third digit is 2, so the command has no effect.

Scan:

To disable UPC/EAN, scan this bar code: Disable UPC/EAN

*$+CE0000* *$+CE0000*

To enable UPC/EAN, scan this bar code: Enable UPC/EAN

*$+CE1000* *$+CE1000*

PSK Example:

im_command (“$+CE1000”,8); will enable UPC/EAN and disallow supplementals.

7-33

Page 236

blank

Page 237

nugget

39 helconital

A Status Codes

Page 238

39 helconital nugget blank

Page 239

Status Codes

A

This appendix lists the status code hex values and their meanings and contains a table of the ASCII character set and ASCII control characters.

Using the Status Code Return Values Most of the PSK functions return status codes. You can use the codes to test for error conditions that your application will act upon. How you test for the status codes depends on the complexity of the function returning the status and your application needs. In most cases, you can use the status code macros discussed in Chapter 2, “Programming Guidelines,” to determine success or failure. In other cases, you can check for the exact status code value. The next table lists the status code return values and the error message text provided by im_message. The status codes are in hex. Note: The status codes are IM_USHORT (unsigned short) values.

6400 Status Code Return Values Status Code

Message Text

0x000

Successful operation (IM_SUCCESS or IM_OK)

0x051

Response larger than buffer

0x052

Invalid command

0x053

Set attribute with bad value

0x054

Write to read-only attribute Attempted to write a value to a read-only attribute

0x055

General error not covered

0x056

Incorrect parameter or string length

0x057

Queue or pool empty

0x058

Action not permitted from this origin

0x059

Indicates that a DLE character has been found and must be removed from the input string

0x05A

During config. parsing, a digit was expected While parsing a configuration command, expected a digit but encountered another value

0x060

Queue is full

0x061

UDP+: Buffer too large to send

0x062

UDP+: NULL buffer was passed

A-3

Page 240

6400 PSK Reference Manual

6400 Status Code Return Values (continued) Status Code

Message Text

0x063

UDP+: Msg received bigger than buffer

0x064

UDP+: Msg already transmitted

0x065

UDP+: Invalid param block

0x066

Network is inactive or improperly configured

0x067

Network control block pointer is null

0x068

Data pointer is null or data length is invalid

0x069

Data length exceeds 1024

0x06A

Send buffer contains a previous application message

0x06B

Incorrect RF configuration

0x070

The Ninit usnet call failed

0x071

The Nportinit usnet call failed

0x072

The Nterm usnet call failed

0x073

The Portterm usnet call failed

0x074

The Nopen usnet call failed

0x075

The Nclose usnet call failed

0x076

The Nread usnet call failed

0x077

The Nwrite usnet call failed

0x078

Invalid group event

0x079

Network PM failed

0x07A

Invalid send buffer

0x07B

The send buff is not empty

0x07C

A failure occurred in udp timer

0x07D

Maximum number of bad sequence numbers has occurred. Possible duplicate IP address in network.

0x07E

Could not connect to controller

0x080

File open failed

0x081

Read or Write request failed

0x082

The getbuf usnet call failed

0x083

Data or ACK receive failed

0x084

File write failed

0x085

File close failed

0x0A1

Invalid sub-function request

A-4