The text of a manual · part 22 of 28
6400 PSK Reference Manual, pages 211 to 220
Pages 211 to 220 of 272
The original document is the PDF (1.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 6400
Page 211
Configuration Command Reference
7
Beep Volume Purpose:
Set the beep volume according to operator preference and work environment.
Syntax:
BVdata Acceptable values for data are: 0 2
Default: Scan:
Off Normal
Normal One of these bar codes: Beep Volume Off
Beep Volume Normal
*$+BV0*
*$+BV2*
*$+BV0*
PSK Example:
*$+BV2* im_command (“$+BV2”,5); will set the beep volume to normal.
Codabar Purpose:
Enables or disables decoding of Codabar symbology. Codabar is a self-checking, discrete symbology. The American Blood Commission (ABC) Codabar requires that you retain and transmit the start/stop code digits when processing a Codabar symbol. Start/stop code digits are always transmitted.
Syntax:
CDdata Acceptable values for data are one or two digits, corresponding to:
Default: Note:
First digit
0 2
Disabled Enabled
Second digit
0 or 1
Ignored
Disabled The configuration CD20 is not permitted for consistency with other Intermec products.
7-9
Page 212
6400 PSK Reference Manual
Scan:
One of these bar codes: Disabled
Enable ABC, Transmit ABCD Start/Stop
*$+CD00*
*$+CD11*
*$+CD00*
PSK Example:
*$+CD11* im_command (“$+CD11”,6); will enable codabar.
Code 39 Purpose:
Enables or disables decoding of Code 39 symbology. Code 39 is discrete, variable length, and self-checking. The character set is uppercase A to Z, 0 to 9, dollar sign ($), period (.), slash (/), percent (%), space ( ), plus (+), and minus (-). The maximum character length for a label is 23 characters. The 6400 decodes three types of ASCII: •
Code 39 non-full ASCII
•
Code 39 full ASCII
•
Code 39 mixed-full ASCII
Code 39 non-full ASCII Non-full ASCII uses a one-character encoding scheme. For example, you encode the data “SAMPLE” as follows:
*SAMPLE* *SAMPLE*
This label decodes as SAMPLE. Code 39 full ASCII Full ASCII uses a two-character encoding scheme to extend the character set to 128 characters. You use the dollar sign ($), slash (/), percent (%), or plus (+) followed by an uppercase letter to represent one of the characters in the extended set. You must encode lowercase letters as a plus sign (+) followed by their uppercase equivalents. For a list of ASCII characters and their Code 39 representations, see the “Full ASCII Table” in Appendix C. Use Code 39 full ASCII to enter ASCII control characters or lowercase characters as data. You should also enable Code 39 full ASCII to use ASCII command characters. For example, you encode the data “sample” in Code 39 full ASCII as follows:
*+S+A+M+P+L+E* *+S+A+M+P+L+E*
7-10
Page 213
Configuration Command Reference
7
Code 39 (continued) In Code 39 non-full ASCII, this label decodes as +S+A+M+P+L+E. In Code 39 full ASCII, this label decodes as sample. Code 39 mixed-full ASCII Use mixed-full ASCII when printers encode the same label two different ways. For example, if you have a bar code with the data $%a, some printers encode the data as follows:
*/D/E+A* */D/E+A*
In the “Full ASCII Table” in Appendix C, /D represents $ and /E represents %. If you configure the 6400 for Code 39 full ASCII, the 6400 decodes the data as $%a because there are three valid full ASCII character pairs to represent the data. Other printers encode the data $%a as:
*$%+A* *$%+A*
The $ and % are valid Code 39 characters in the non-full ASCII character set. However, the 6400 will not decode this label if it is configured for full ASCII because the data is not represented by valid full ASCII character pairs. To decode the label correctly, you need to configure the 6400 for mixed-full ASCII. When you configure the 6400 for Code 39 mixed-full ASCII, the 6400 will decode both of the labels above as $%a. Mixed-full ASCII interprets any valid full ASCII character pairs that appear in the label, but does not require that all data be encoded with a valid full ASCII character pair. If you are uncertain how your labels are encoded, configure the 6400 for mixedfull ASCII, which decodes all valid Code 39 labels. If you configure the 6400 for Code 39 full ASCII, you should check for Code 39 mixedfull ASCII. Mixed-full ASCII does not apply when you configure the 6400 for non-full ASCII. Note: The interpretive text shown under bar code labels does not always accurately reflect the data that is encoded in the label. The interpretive text represents how the label should be decoded.
7-11
Page 214
6400 PSK Reference Manual
Code 39 (continued) Use this table to help configure your 6400.
Syntax:
Code 39 Option
Bar Code Label
Decodes
Non-full ASCII
$%+A /D/E+A
$%+A /D/E+A
Full ASCII
$%+A /D/E+A
No decode $%a
Mixed-full ASCII
$%+A /D/E+A
$%a $%a
CBdata Acceptable values for data must be three digits, corresponding to:
Default: Scan:
First digit:
0 1
Disabled Enabled with no check digit
Second digit:
0 1
Ignored Ignored
Third digit:
0 1 2
Code 39 non-full ASCII Code 39 full ASCII Code 39 mixed-full ASCII
Enable Code 39 Full ASCII with no check digit (111) To disable Code 39: Disable Code 39
*$+CB000* *$+CB000*
To enable Code 39 with non-full ASCII: Enable Code 39, non-full ASCII
*$+CB110* *$+CB110*
To enable Code 39 with full ASCII: Enable Code 39; full ASCII
*$+CB111* *$+CB111*
7-12
Page 215
Configuration Command Reference
7
Code 39 (continued) To enable Code 39 with mixed-full ASCII: Enable Code 39; mixed-full ASCII
*$+CB112* *$+CB112*
PSK Example:
im_command (“$+CB110”,7); will enable Code 39 non-full ASCII.
Note:
For compatibility with other Intermec products, the second digit must be included. Even though it is ignored, it must be 0 or 1. All digits must be in the valid ranges shown; otherwise, the command is invalid and has no effect.
Code 128 Purpose:
Enables or disables decoding of Code 128 symbology. Code 128 is a very high density alphanumeric symbology that supports the extended ASCII character set. It is a variable length, continuous code that uses multiple element widths.
Syntax:
CHdata Acceptable values for data are: 0 1
Default: Scan:
Disabled Standard Code 128
Standard Code 128 One of these bar codes: Disable Code 128
Enable Standard Code 128
*$+CH0*
*$+CH1*
*$+CH0*
Notes:
*$+CH1*
If you configure Standard Code 128, the 6400 will not decode Function Code 1 characters in the first position of a bar code label. Any subsequent Function Code 1 characters are translated to the ASCII GS control character as a separator for variable length fields. UCC/EAN function code 1 extensions are not supported.
PSK Example:
im_command (“$+CH1”,5); will enable standard Code 128.
7-13
Page 216
6400 PSK Reference Manual
Command Processing Purpose:
Command processing allows you to disable or enable reader commands. For example, you can disable the Backlight command. You may want to disable reader commands to prevent a user from accidentally entering a command, or to use data that would otherwise be treated as a command. Any bar code label that contains the 2- to 4-character commands for Command Processing is treated as a reader command unless the command is disabled.
Syntax:
DCdata Acceptable values for data are: 0 1 2 3 command0 command1
Disable all reader commands Enable all reader commands Disable override Enable override Disable reader command Enable reader command
The override option is a temporary setting that allows you to enable all the reader commands for as long as you need them. When you want to return to the previous configuration, you disable the override. Note: The Enable Override option is the only bar code label you can scan to enable reader commands if you have disabled all reader commands (DC0). Default: Scan:
Enable all reader commands To enable all the reader commands or override the current settings, scan one of these bar codes: Disable All Reader Commands
Enable All Reader Commands
*$+DC0*
*$+DC1*
Disable Override
Enable Override
*$+DC2*
*$+DC3*
*$+DC0*
*$+DC2*
7-14
*$+DC1*
*$+DC3*
Page 217
Configuration Command Reference
7
Command Processing (continued) Or:
To disable or enable specific reader commands, perform these steps: 1. Scan this bar code: Enter Accumulate Mode / Command Processing
*+/$+DC* *+/$+DC*
2. Scan the bar code to disable or enable one reader command. Abort Program
Backlight
*/$*
*%.*
*/$*
*%.*
Change Configuration
*$+* *$+*
Default/Save Configuration
Delete File
*.+*
*..--*
Exit Accumulate Mode
(continued)
*.+*
*-*
*..--*
*/*
*-*
*/*
Receive File
Rename File
*.%*
*...-*
Reset
Run Program
*.%*
*-.* *-.*
*...-*
*//*
*//*
Transmit File
*%%* *%%*
7-15
Page 218
6400 PSK Reference Manual
Command Processing (continued) 3. Scan one of these bar codes: Disable the Command
Enable the Command
*0*
*1*
*0*
*1*
4. Repeat Steps 2 and 3 to disable or enable another reader command. Note: You can accumulate up to 250 characters in the buffer. If the data accumulated exceeds 250 characters, you will hear an error beep and the 6400 will reject the last bar code read. 5. Scan this bar code: Exit Accumulate Mode
*-/* *-/*
PSK Example:
im_command (“$+DC1”,5); will enable all reader commands.
7-16
Page 219
Configuration Command Reference
7
Configuration Commands Via Serial Port Purpose:
Allows you to control the data the 6400 receives through the serial port. You can set this command to execute reader and configuration commands received through the serial port, or treat all data as data without checking for special command syntax. There are two options: Disabled All data received through the serial port is treated as data. The 6400 will not execute reader or configuration commands sent or encoded in the data. Enabled The 6400 will check for and execute all reader and configuration commands (i.e., Receive File reader command or Beep Volume change configuration command). Note: Before you can enable Configuration Commands Via Serial Port, you must configure the EOM command.
Syntax:
ITdata Acceptable values for data are: 0 2
Default: Scan:
Disabled Enabled
Enabled One of these bar codes: Commands Via Serial Port Disabled
Commands Via Serial Port Enabled
*$+IT0*
*$+IT2*
*$+IT0*
PSK Example:
*$+IT2* im_command (“$+IT2”,5); will enable commands via serial port.
7-17
Page 220
6400 PSK Reference Manual
Data Bits Purpose:
Sets the number of data bits the 6400 uses when communicating with another device (i.e., host computer) through the serial port.
Syntax:
IIdata Acceptable values for data are: 7 8
Default: Scan:
7 data bits 8 data bits
7 data bits One of these bar codes: 7 Data Bits
*$+II7* *$+II7*
PSK Example:
8 Data Bits
*$+II8*
*$+II8* im_command (“$+II8”,5); will set the serial port to send and receive 8 data bits.
Display Backlight Timeout Purpose:
Defines the amount of time the backlight remains on. The backlight timeout setting significantly affects the 6400’s battery life. If you set a longer backlight timeout value, you use the power in the battery pack at a faster rate.
Syntax:
DFdata Acceptable values for data are: 0 1 - 15
Default: Scan:
Disabled Timeout in minutes
10 seconds To disable the backlight timeout, scan this bar code: Disable Backlight Timeout
*$+DF00* *$+DF00*
7-18