Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 9 of 16

5020 Data Collection PC User's Manual: Chapter 2: Configuring the 5020, pages 73 to 80

Pages 73 to 80 of 144, from 5020 Data Collection PC User's Manual

The original document is the PDF (2.0 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Intermec 5020

Page 73

Configuring the 5020

& &

2

11. If your DHCP server is configured to automatically set the Primary and Secondary DNS addresses, press . The Radio dialog box appears.

&

If your server will not automatically set the DNS addresses, enter them now. When finished, press . The confirmation dialog box appears. Press . Note: If your 5020 comes with a radio, the Radio dialog box (either OpenAir or 802.11) appears. Continue with Step 12. On a batch 5020, the Identification dialog box appears. Go to Step 14.

3

12. Press to move from field to field in the Radio dialog box. Enter information with the alphanumeric keys. For help, see “Using the Keypad” in Chapter 1.

4 to place a Note: To enable WEP encryption for the 802.11b HR radio, press check mark in the box. For WEP 64 encryption, the WEP key must be 5 characters in length. For WEP 128, the WEP key must be 13 characters in length. Other WEP parameters must be set using the Configuration application. For help, see “Using the Configuration Application” later in this chapter.

&

&

13. Press . The confirmation dialog box appears. Press . The Identification dialog box appears.

2-9

Page 74

5020 Data Collection PC User's Manual

&

& &

14. Enter a name for the 5020 in the Device Name field. When finished, press . The confirmation dialog box appears. Press . An alert message appears. Note: You may not need to enter a name for your 5020. If this is true, press . An alert message appears.

&

15. The alert message reminds you that you must turn the 5020 off and back on again to enable the changes. Press . The Congratulations message appears.

16. Press

& to close Fast Config. Press

' twice to turn the 5020 off and back on again.

The 5020 should now be communicating with your wired or RF network. When an RF 5020 is in range of the access point, the icon appears and remains on in the Notification Tray icon, the indicating that the 5020 is communicating with the access point. If you see the 5020 is unable to connect to the access point. See Chapter 4, “Troubleshooting and Maintenance,” for help. If you are using a UDP Plus network, you need to use the Configuration application to set UDP parameters and enable the network. For help, see “Enabling UDP Plus” in Chapter 3.

2-10

Page 75

Configuring the 5020

2

Using the Configuration Application You can use the Configuration application to

• • • view, change, or set all parameters in real time. restore factory defaults to a selected group of parameters or all parameters as needed. view system and terminal information.

Note: You can also extend and customize the Configuration application. For help, see Appendix D, “Extending the Configuration Applications,” in the 502X system manual.

! !

To use the Configuration application

1. Press 2. Press 3. Press to open the Start menu.

9 to highlight Programs and then press .

to highlight Configuration.

&

4. Press . The Configuration main screen appears.

2-11

Page 76

5020 Data Collection PC User's Manual

The Configuration main screen includes four menu options: Choose the File menu to close a menu or screen, apply changes, refresh the screen to the previous settings, restore factory defaults, and exit the Configuration application.

File

The Edit menu options undo, cut, copy, and paste are reserved for future use.

Edit

Choose this menu to view and set data collection, unit, IE browser, network, and SNMP parameters. For help using the Configure menu, see the next section.

Configure

Choose this option to check the charge status of the main and bridge batteries or view terminal version information. For help, see “Viewing Terminal Information” later in this chapter. Troubleshoot

"" " & ! " &

5. To select a menu, press plus the application menu shortcut. For example, to select the Configure menu, press on Standard keypad). C( 6. Use

!

and to select a menu option and then press .

7. To exit the Configuration application, press on the Standard F( keypad) to open the File menu. Press to highlight Exit and then press .

Viewing and Changing Parameters Select items in the Configuration menu to view parameter groups and change the configuration settings of your 5020.

To view and change parameter settings in the Configuration application

1. If the Configuration application is not open, press Configuration. 2. Press

2-12

" C (

. Choose Programs and then on Standard keypad) to open the Configure menu.

Page 77

Configuring the 5020

2

The Configure menu lists these five parameter groups: Includes bar code symbologies and symbology identifiers, scanner parameters, decode options, and virtual wedge settings. Data Collection

Includes display, audio, and keypad options; date and time; serial port baud rate; and power management. Unit

Includes browser connection, home page and cache settings, and function key URLs. Internet Explorer (IE) Browser

Network

!

SNMP

Includes all network settings such as Ethernet protocols and radio options.

&

Includes SNMP security, trap, and identification parameters.

3. Use and to select a parameter group and press . The configuration screen for that group appears. For example, the Network screen is shown here.

3

4. Use the and arrow keys to navigate in the configuration screen. Make the changes you need for each parameter. For help, see the next section.

&

3 ! " & '

5. To save your changes in each configuration screen, press and then press .

to select the Apply button

6. To exit the Configuration application, press on the Standard F( keypad) to open the File menu. Press to highlight Exit and then press . 7. If you changed any network settings, press twice to make the changes effective.

Note: If you changed the UDP Plus Enable parameter, warm boot the 5020. For help, see “Booting the 5020” in Chapter 4. See the next illustration to see how the parameters are listed in each of the five groups. The illustration shows the first level of parameters in each group. To find a parameter not shown in the illustration, see the command name in Chapter 7 of the 502X system manual.

2-13

Page 78

5020 Data Collection PC User's Manual

Configuration Parameters at a Glance

File Edit Configure Troubleshoot

File Edit Configure Troubleshoot

File Edit Configure Troubleshoot

Data Collection Unit IE4 Browser Network SNMP

Data Collection Unit IE4 Browser Network SNMP

Data Collection Unit IE4 Browser Network SNMP

Scanner

Timeout Mode Trigger Mode Redundancy Selection

Date/Time Display

Backlight Timeout Backlight Level Key Clicks Caps Lock On

Decode Options

Decode Security Level Decode Priority

Keypad

Virtual Wedge Preamble Postamble Grid Code Page

Power Management

Automatic Shutoff

Virtual Wedge

Serial Port

IrDA Baud Rate

Speaker

Volume Low Beep Frequency High Beep Frequency Low Beep Duration High Beep Duration

Symbologies

Code 39 Interleaved 2 of 5 Code 2 of 5 Codabar Code 93/93i Code 11 Code 49 MSI Code 16K UPC/EAN Plessey Code 128 PDF 417

Symbology ID

Code 39 ID Code 128 ID Codabar ID Code 93 ID Code 11 ID Interleaved 2 of 5 ID Code 16K ID PDF 417 ID MSI ID Plessey ID Straight 2 of 5 (2 bar SS) ID Straight 2 of 5 (3 bar SS) ID Code 49 ID Code 49 Function Code 1 ID Code 49 Function Code 2 ID Code 49 Function Code 3 ID UPC A ID UPC E ID EAN 8 ID EAN 13 ID

Home Page Cache Size (KB) Underline Links Use LAN (no auto dial) Use Proxy Server

Date and Time Options

F6 key F7 key F8 key F9 key F10 key

Function Key URLs

File Edit Configure Troubleshoot

File Edit Configure Troubleshoot

Data Collection Unit IE4 Browser Network SNMP

Data Collection Unit IE4 Browser Network SNMP

Protocols

(RF 5020s only) Radio or Ethernet

(Batch 5020s only)

UDP Plus TFTP IDRS

Security

IP Address Name Servers TCP/IP Extensions Radio

Read Only Community String Read/Write Community String Read Encryption Write Encryption Encryption Key

Traps

Authentication Threshold

Identification

Contact Name Location

IP Address Name Servers

Advanced

Config Manager Enable Config Subagent Enable UDP Plus Enable

Identification

Device Name

5020U312.eps

Note: In the Network parameter group, you will see either Radio or Ethernet when the corresponding card has been installed in your 5020. If the correct tab does not appear, see Chapter 4, “Troubleshooting and Maintenance.”

2-14

Page 79

Configuring the 5020

2

Navigating in the Parameter Screens This section explains how to navigate around the parameter screens, change parameters, and apply changes. The next illustration shows the different areas and buttons on each parameter screen.

Focus

Parameter tabs

Parameter list

Parameter group (from Configure menu)

Buttons

Parameter options

The focus in this illustration is the box around the Security parameter tab, indicating that the tab is the active section of the screen. When you move the focus to the parameter list or parameter options area, the focus changes to highlight the parameter or option. When you move the focus to a button, the button box outline appears darker. Read-only parameters will not appear in the parameter options area. Here is a summary of the keys you use to navigate in the Configuration application. Detailed instructions are also listed next. To Do This

Move the focus from one area to the next within a tab Move the focus in reverse order within a tab Select the next parameter tab. If the focus is on a tab, you can also press to select the next parameter tab. Move up and down in the parameter list Toggle through the options in a drop-down list Move the focus through the options in an option button list Expand a parameter list for a parameter marked with a plus sign

3 63 7 9 $3 ! 9 7 $9 Press or and

Close or collapse a parameter list for a parameter marked with a negative sign Scroll a tab to the right to view information

2-15

Page 80

5020 Data Collection PC User's Manual

To select another parameter tab

• •

7 9 $3

With the focus on a parameter tab, press

3 or .

If the focus is not on the tab, press to select the next tab. For example, press to move the focus from an item in the Date/Time tab to the Display tab.

3

To select a parameter

1. Press 2. Press

!

until the first parameter in the parameter list is highlighted. or

3 !

to select a parameter in the list.

For example, press to move the focus from the Display tab to the first parameter, Backlight Timeout. Press to select the next parameter, Backlight Level.

3 ! 9

To view an expanded parameter list

1. Press 2. Press to move the focus to the parameter list area.

or to select a parameter that is marked with a plus sign .

9

3. Press . The expanded parameter list appears. For example, if the focus is on the parameter Obtain IP Address via DHCP, press to see the expanded parameter list.

2-16

$