Page 65
2 Configuring the 5020
Page 66
white
Page 67
Configuring the 5020
2
This chapter explains how to configure the 5020 using several different methods.
How to Configure the 5020 You can set many operating characteristics of the 5020 Data Collection PC, such as the bar code symbologies it decodes or settings for network connections. These characteristics are controlled by configuration parameters. The values that you set for the parameters determine how the computer operates. There are several ways to configure the 5020: Use Applications on the 5020
Scan Bar Codes 502X Intro Fast Config
Programs
ActiveSync
Settings...
IE Browser
Run...
DCPC Demo
Goto User Mode
Suspend
Use the Control Start Panel applets for local unit settings.
+ -
Scan bar codes to configure basic unit and data collection parameters.
Varadero PC Connection Configuration
Use Fast Config to quickly enter network parameters, or use the Configuration application to set all parameters. Use SNMP Commands
Use Web Browser
Use an SNMP management station to configure all 5020s on your network.
Intermec 5020 Configuration Management
Intermec 5020 Configuration Management
Ethernet or RF Network
Ethernet or RF Network Use a Web browser on your desktop PC with Configuration Management to configure parameters for each 5020 on your network.
5020U077.eps
2-3
Page 68
5020 Data Collection PC User's Manual
When first setting up the 502X, use Fast Config to set or enable most basic network parameters and get the 502X connected to your network. For help, see “Using Fast Config” later in this chapter. Use the Fast Config Application
You can use the Configuration application to configure all parameters. The 5020 does not need to be connected to your network to use its Configuration application. For help, see “Using the Configuration Application” later in this chapter. Use the Configuration Application
Scan Bar Codes You can scan bar code labels to configure basic scanning parameters including symbology enabling and scanner operation. For help, see “Configuring the 5020 by Scanning Bar Code Labels” later in this chapter.
You can change local unit settings such as memory allocation or dialing properties using the Control Panel applets. For help with the Control Panel, see Chapter 3, “Customizing the 502X Using the Control Panel,” in the 502X Data Collection PC System Manual (Part No. 071479). Use Control Panel Applets
After the 5020 is communicating in your network, you can use a Web browser on a desktop PC and the Configuration Management application in Unit Manager to configure all parameters and remotely manage your 5020. You can configure parameters for all 5020s on your network one at a time using Configuration Management from your desktop. For help, see “Using Configuration Management” in Chapter 4 of the 502X system manual. Use the Configuration Management Application
Use SNMP Commands After the 5020 is communicating in your network, you can use an SNMP management station to send SNMP commands to the 5020. For help, see “Configuring the 502X by Using SNMP” in Chapter 2 of the 502X system manual.
2-4
Page 69
Configuring the 5020
2
Using Fast Config The Fast Config application is designed to help you quickly enter basic network parameters and get the 502X connected to your wired or RF network. Fast Config presents a series of dialog boxes that allows you to set network parameters including • date and time.
• baud rate of a host PC serial port.
•
DHCP server enabling.
•
IP address, subnet mask, and default router.
• primary and secondary WINS addresses.
• primary and secondary DNS addresses.
• security ID and domain for OpenAir radios.
• network name and WEP key for 802.11b HR radios.
• device name.
To set parameters for data collection, SNMP, UDP Plus, and advanced features of an RF network, use the Configuration application. For help, see “Using the Configuration Application” later in this chapter. For more information on configuration parameters, see Chapter 7, “Configuration Command Reference,” in the 502X system manual. A typical Fast Config dialog box looks like this:
3
Press to move from field to field. Press the arrow keys to move the cursor within a field. Enter information with the keypad. For help, see “Using the Keypad” in Chapter 1.
&
Most of the Fast Config dialog boxes have three buttons: Next, Back, and Finish. The Next button is the default selection. Press to proceed to the next dialog box. Press
3
& & to select the Back or Finish buttons:
•
Select Back and press to return to the previous dialog box. For example, you could go back if you think you entered incorrect information.
•
Select Finish and press to close Fast Config. For example, you could choose Finish if you needed to change an item in only one of the dialog boxes.
2-5
Page 70
5020 Data Collection PC User's Manual
&
If you make changes in a dialog box and press , a confirmation dialog box appears:
The Yes button is the default selection. Press in the current dialog box. Press
3
& to immediately apply all changes you made
& to select the No or Cancel buttons:
•
Select the No button and press to continue without applying the changes you made in the current dialog box. For example, you could select No if you think you entered incorrect information and wanted to keep the previous settings intact.
•
Select the Cancel button and press
& to return to the current dialog box.
You can also exit Fast Config at any time by pressing d. All pending changes will be lost. Note: Before using Fast Config with a batch 5020, install an Ethernet card in the PC card slot. For help, see “Using PC and Compact Flash Memory Cards” in Chapter 1. For an RF 5020, be sure you are in range of an access point.
'
9
To set network parameters using Fast Config
1. Press 2. Press 3. Press 4. Press
2-6 to turn on the 5020.
9 & to open the Start menu.
to select Programs and press . The Programs menu appears.
to select Fast Config and press . The Welcome screen appears.
Page 71
Configuring the 5020
5. Press
&
2 to start Fast Config. The Date and Time screen appears.
3 &
Press to move from field to field. Set the correct time and date using the arrow keys. For more information, see “Using the Keypad” in Chapter 1. 6. Press . A confirmation dialog box appears, prompting you to apply the changes.
&
7. Press to continue. The Communications dialog box appears with the default baud rate (115200) selected.
&
Note: If your 5020 is not connected to a D5020 Communications Dock or an L5020 Serial Communications Adapter, a baud rate error message appears. Press to clear the error message. The Communications dialog box appears without a baud rate selected.
2-7
Page 72
5020 Data Collection PC User's Manual
&
&
8. Press to accept the default baud rate. The confirmation dialog box appears. Press . The Network dialog box appears.
&
4
9. If you are using a DHCP server, press . The WINS dialog box appears.
3
If you are not using a DHCP server, press to clear the check mark from the box. You must enter values in the IP Address, Subnet Mask, and Default Router fields. Press to move the cursor from field to field. Enter values with the number keys and use the arrow keys to move within a field. When finished, press . The confirmation dialog box appears. Press . The WINS dialog box appears.
&
&
&
10. If your DHCP server is configured to automatically set the Primary and Secondary WINS addresses, press . The DNS dialog box appears.
&
&
If your server will not automatically set the WINS addresses, enter them now. When finished, press . The confirmation dialog box appears. Press . The DNS dialog box appears.