For the Intermec 5020
Page 81
Configuring the 5020
!
2
To close or collapse an expanded parameter list
1. Press
7 or to select a parameter that is marked with a negative sign .
7
2. Press to close the expanded list. For example, if the focus is on the parameter Obtain IP Address via DHCP, press to close the parameter list.
3 ! 3
To change a parameter
1. Press to move the focus to the parameter list area.
9
2. Press or to select a parameter. If necessary, press to expand a parameter list. Parameter values that you can change will appear in the options area as you select them. 3. Press to move the focus to the options area.
4. Change the parameter. There are four types of entry fields: •
!
Drop-down list: Press or to toggle through the options until the option you want is highlighted.
•
Entry field or box:
7 9 4 5
Type or scan a value. To enter an IP address, use the or keys to move the cursor between segments of the IP address field. To edit the data in an entry field, use the arrow keys, , or .
2-17
Page 82
5020 Data Collection PC User's Manual
•
4
Check box Press option.
• to check or clear the
!
Option button list Press or to move the focus to the option you want to select.
3 &
&
5. Repeat Steps 1 through 4 to change another parameter in the same parameter tab. 6. Press to move the focus to the Apply button and then press . A message box appears, asking you to confirm the changes. 7. Press to confirm the changes and exit the message box.
Refreshing Parameter Settings You can refresh or reset any parameters until you press the Apply button to save the changes. A refresh discards all unapplied edits and resets the values to the previous saved value. A refresh also refetches and synchronizes the values for read-only parameters like DHCP status and access point name. After you apply changes, you cannot refresh the parameters to the previous settings. However, read-only parameters are always updated when you refresh.
3 & & 3 &
To refresh settings
1. Press to move the focus to the Refresh button or choose Refresh from the File menu.
2. Press to refresh the parameters in the current screen. A message box appears to confirm the refresh. For example, if the Scanner configuration screen is displayed on the 5020 screen and you choose refresh, the 5020 only refreshes the scanner parameters. 3. Press to choose Yes or press
9
& & to select No and then press .
4. Press to move the focus to the Apply button and then press . A message box appears to confirm the changes. 5. Press
2-18 to exit the message box.
Page 83
Configuring the 5020
2
Restoring Factory Defaults In the Configuration application, there are two ways to restore factory default parameters: •
You can select the Defaults button in a parameter screen to restore the defaults to all the parameters listed on that screen.
•
You can select Restore Factory Defaults from the File menu to restore the defaults to all parameters. Note: Because using the Restore Factory Defaults option resets all network parameters, a loss of network communications may result. This option should only be used by your network administrator or by Intermec support personnel. After using this option, a warm boot may be necessary to restart the 5020.
For a list of the default values, see Appendix A, “502X Default Configuration," in the 502X system manual.
3 & & 3 &
To restore factory defaults in the current Configuration screen
1. Press to move the focus to the Defaults button.
2. Press to restore the default parameters in the current screen. For example, if the Scanner parameters tab is onscreen and you choose to restore the defaults, the 5020 sets only the Scanner parameters to the factory defaults. A confirming message box appears. 3. Press 4. Press 5. Press to choose Yes or press
9
&
& to select No and then press .
to select the Apply button and then press . A confirming message box appears.
to close the box and restore defaults to the parameters in the current screen.
To restore factory defaults to all parameters
" ! &
1. Be sure a Configuration menu is onscreen (not the Configuration main screen). 2. Press
F(
& on the Standard keypad) to open the File menu.
3. Press to choose Restore Factory Defaults and press . A confirming message box appears. 4. Press to close the message box and restore all parameters to their default conditions.
2-19
Page 84
5020 Data Collection PC User's Manual
Viewing Terminal Information Choose Unit Information in the Troubleshoot menu to view battery charge status and terminal information. To view terminal information
1. If the Configuration application is not open, press Configuration.
&" " 0
. Choose Programs and then
2. Press on the Standard keypad) to open the Troubleshoot menu and T( press . The Unit Information screen appears.
7 9
The Battery Status tab shows the charge level of the main and bridge batteries. 3. Press or to move the focus to the Terminal Version tab, which shows the 5020’s
• model number.
• serial number.
• manufacturing software version.
• current software version.
• current software build.
•
PCB part number.
•
RFID part number (where applicable).
• last day serviced.
%
4. Press to close the Unit Information screen and return to the main Configuration application screen.
2-20
Page 85
Configuring the 5020
2
Configuring the 5020 by Scanning Bar Code Labels You can configure the 5020 by scanning bar code labels listed in the 502X system manual or by creating your own Code 39 or Code 93 bar code labels. For configuration bar codes listed by name, see Chapter 7, “Configuration Command Reference,” in the 502X system manual. Here are the commands that you can configure or enable using bar code labels: •
Automatic Shutoff
•
Interleaved 2 of 5
•
Beep Duration
•
Keypad Caps Lock
•
Beep Frequency
•
Keypad Clicker
•
Speaker Volume
•
MSI
•
Codabar
•
PDF 417
•
Code 11
•
Plessey
•
Code 16K
•
Postamble
•
Code 2 of 5
•
Preamble
•
Code 39
•
Scanner Mode
•
Code 49
•
Scanner Redundancy
•
Code 93/93i
•
Scanner Selection
•
Code 128
•
Scanner Timeout
•
Decode Priority
•
Scanner Trigger
•
Decode Security
•
Symbology Identifier
•
Display Backlight Timeout
•
UPC/EAN
You need to configure all other commands using the Configuration application, the Configuration Management application in Unit Manager, or SNMP.
2-21
Page 86
5020 Data Collection PC User's Manual
When you scan bar code configuration commands, the 5020 sounds an audio signal unless the beep volume is turned off. There are two beep sequences: •
Low beep, low beep, high beep, high beep means you scanned a valid configuration command.
•
Three low beeps means you scanned an invalid configuration command.
You can create bar code labels that contain more than one configuration command. For example, you can create one bar code label to configure the computer for •
One-Shot Scanner mode (SB0).
•
Scanner Redundancy set to high (SR2).
One-Shot Scanner Mode, Set Scanner Redundancy to High
*$+SB0SR2* *$+SB0SR2*
When you create bar code labels to set one or more configuration commands, follow these rules: •
The bar code label must be printed using Code 39 or Code 93/93i symbology.
•
The bar code label must include the start and stop character. Most bar code printing utilities automatically include the start and stop character.
•
The bar code label must start with $+ (Change Configuration command).
•
Each configuration command must include the command syntax and the value for the command. For example, BV is the command syntax for Beep Volume and the value 4 sets the speaker volume to loud.
•
If you set one configuration command to a string of ASCII characters and another configuration command follows, you must enclose the value in quotation marks. If you do not include the quotation marks, the computer will interpret everything after the first command as data and will not find the second configuration command. For example, to set the preamble to BV, use $+ADBV (no quotation marks are needed). To set the preamble to BV and turn off the beep volume, use $+AD"BV"BV0, or change the order and use $+BV0ADBV. To clear the preamble and postamble from a single label, use $+AD""AE.
•
2-22
To include quotation marks when you set a value, the entire value must be enclosed in quotation marks. Type two sets of quotation marks ("") to include one quotation mark as the value for a command. For example, to set the preamble to ABC"D, use $+AD"ABC""D".
Page 87
Configuring the 5020
2
Configuring the 5020 Remotely After the 5020 is communicating in your network, you can configure it by • using a Web browser and the Configuration Management application in Unit Manager.
• sending SNMP commands from an SNMP management station.
You can use a Web browser on a desktop PC and the Unit Manager applications to configure all parameters and remotely manage your 5020. You can configure parameters for all 5020s on your network one at a time using the Configuration Management application in Unit Manager from your desktop. For help, see Chapter 4, “Using Unit Manager,” in the 502X system manual. You can also send SNMP commands to the 5020 from an SNMP management station to configure the 5020. For help, see “Configuring the 502X by Using SNMP”in Chapter 2 of the 502X system manual. For help with connecting the 5020 to your network, see Chapter 3, “Connecting the 5020.”
2-23
Page 88