Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 11 of 16

5020 Data Collection PC User's Manual: Chapter 3: Connecting the 5020, pages 89 to 97

Pages 89 to 97 of 144, from 5020 Data Collection PC User's Manual

The original document is the PDF (2.0 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Intermec 5020

Page 89

3 Connecting the 5020

Page 90

white

Page 91

jjjj39

Connecting the 5020 helveticacondensed

3

Connecting the 5020 To Your Network You can easily use the 5020 as an end device in your wired or RF network. There are several ways to connect the 5020 to your network: •

Install an Ethernet card (purchased separately) in a batch 5020 to communicate with other devices in your network.

•

Use the radio in an RF 5020 to communicate with other RF devices in your network.

•

Use the IrDA port or install a serial I/O card (purchased separately) to transfer data between the 5020 and a host computer.

To configure your 5020 for an Ethernet or RF network, see “Setting The Network Parameters” later in this chapter. To configure and use the IrDA port, see “Configuring for Serial or IrDA Communications” later in this chapter.

Learning About Network Protocols The 5020 communicates using either of these network protocol options: •

TCP/IP

•

UDP Plus

The 5020 ships with TCP/IP enabled. In a TCP/IP network, the 5020 communicates directly through the access points or through the Ethernet network to the host or server. UDP Plus is an Intermec protocol built on top of the User Datagram Protocol (UDP). It maximizes the performance of RF networks and provides robust data communications. In a UDP Plus network, the 5020 communicates through the DCS 30X to the host or server. If you have a DCS 30X network, you must enable UDP Plus on the 5020. TCP/IP

5020

Host

UDP Plus

5020

5020

5020

Access point

Access point

Ethernet DCS 30X

5020

5020

5020

5020

5020U095.eps

3-3

Page 92

5020 Data Collection PC User’s Manual

Helveticcond blk

39jjj

The network parameters you need to set depend on your network environment. If you are using a DHCP (Dynamic Host Control Protocol) server, the 5020 broadcasts a message to the server, and the DHCP server assigns these network parameters: •

IP address

•

Subnet mask

•

Default router

•

Primary and secondary DNS servers

•

Primary and secondary WINS servers

DHCP is automatically enabled on the 5020. If you are not using a DHCP server, you need to disable DHCP and manually set the network parameters. You only need to set the DNS and WINS servers if they are required for your network communications. If you are on a network that uses a WINS server or you want to use universal naming conventions (UNC) such as \\computer_name\share_name\filename, you need to set the device name. For help with setting the device name, see “Setting Communications Properties” in Chapter 3 of the 502X Data Collection PC System Manual (Part No. 071479).

Learning About RF Network Settings (RF 5020s only) Caution Make sure all components with antennas are at least 30 centimeters (1 foot) apart when power is applied. Failure to comply could result in equipment damage. Conseil Assurez-vous que la distance entre tous les éléments avec antennes soit d’au moins 30 centimètres (un pied) avant de faire la connexion avec l’alimentation électrique, faute de quoi vous risquez d’endommager votre installation. Your RF 5020 ships with either an OpenAir radio or an 802.11b HR radio. To connect to an RF network, you need to • configure your access points.

• configure the 5020 radio parameters. For an OpenAir radio, you need to set the security ID and domain. For an 802.11b HR radio, you need to set the network name and WEP key.

The access point acts as a bridge to provide RF communications between the 5020 and the DCS 30X or host. When you first consider purchasing an RF data collection system, an Intermec representative works with you to perform a site survey at your facility. The survey analyzes the range of RF devices in your facility, determines the placement of the access points, and ensures that the access point coverage overlaps to provide uninterrupted RF access at any location within the building. This manual assumes that a site survey is complete and the access points are installed.

3-4

Page 93

jjjj39

Connecting the 5020 helveticacondensed

3

If the host computer communicates with the 5020 through 011X access points, you may need to add the 5020 IP address and MAC address as a static entry in the host’s ARP table. For help, see “Problems With Connectivity” in Chapter 4.

Setting the Network Parameters To quickly get the 5020 connected to your network, you can use the Fast Config application to set these basic network and RF parameters for a TCP/IP network: •

Date and time

•

Baud rate of a host PC serial port

•

DHCP server enabling

•

IP address, subnet mask, and default router

•

Primary and secondary WINS addresses

•

Primary and secondary DNS addresses

•

Security ID and domain for OpenAir radios

•

Network name and WEP key for 802.11b HR radios

•

Device name

After you use Fast Config, the 5020 should be communicating in your network. For help with Fast Config, see “Using Fast Config” in Chapter 2. For a UDP Plus network, follow the Fast Config instructions and then use the Configuration application to enter UDP parameters and enable the network. For help, see “Enabling UDP Plus” later in this chapter. You can also configure each network and radio parameter using the Configuration application. For help, see “Using the Configuration Application” in Chapter 2. After you have connected the 5020 to your network, you can remotely set parameters by using the Configuration Management application in Unit Manager from your desktop PC. For help, see “Using Configuration Management” in Chapter 4 of the 502X system manual. You can also remotely set parameters on the 5020 by sending SNMP commands from an SNMP management station. For help, see “Configuring the 502X by Using SNMP” in Chapter 2 of the 502X system manual.

3-5

Page 94

5020 Data Collection PC User’s Manual

Helveticcond blk

39jjj

Enabling UDP Plus The DCS 30X supports and manages communications with other devices in the RF or Ethernet network. When you install and configure the DCS 30X, you identify the host computer(s) and 5020s in your network. The 5020s communicate through the DCS 30X with your host by using UDP Plus. For help installing the DCS 30X, see the DCS 30X manual. Host

5020

5020

Access point

Ethernet

DCS 30X

5020

5020 5020U081.eps

For the 5020 to communicate with the server, you must perform these tasks on the DCS 30X: •

Configure the UDP Plus network.

•

Assign an IP address to each 5020, or if you are using a DHCP server, set up the DNS Configuration dialog box on the DCS 30X.

•

Enable all 5020s.

•

Define the host environment parameters.

•

Define the host communications parameters.

Next, you need to configure UDP Plus on the 5020. If you have not configured the network parameters, start with the instructions for “Setting the Network Parameters” earlier in this chapter.

3-6

Page 95

jjjj39

Connecting the 5020 helveticacondensed

3

To enable UDP Plus

1. Turn on the 5020 and open the Start menu.

! 3

& 9

2. Start the Configuration application and select the Configure menu. 3. Press to select Network and then press . The Network configuration screen appears.

4. Press to select UDP Plus and then press . The expanded UDP Plus parameter list appears. For a definition of each parameter, see Chapter 7, “Configuration Command Reference,” in the 502X system manual.

5. Choose Controller IP Address and set the IP address of the DCS 30X. You can set other UDP Plus parameters as needed.

$3

6. To save your changes, press 7. Press appears.

3

& to select the Apply button and then press .

three times to select Advanced. The Advanced configuration screen

3-7

Page 96

5020 Data Collection PC User’s Manual

Helveticcond blk

8. Press

3

39jjj and then

!

to select the UDP Plus Enable parameter.

3

9. Press to move to the UDP Plus Enable check box, and then press mark in the box. 10. To save your changes, press

3

'

4 to place a check

& to select the Apply button and then press .

11. Exit the Configuration application and press twice to make the changes effective.

12. Warm boot the 5020 to enable UDP Plus. For help, see “Booting the 5020” in Chapter 4. The 5020 should now be communicating in your UDP Plus network. When the 5020 is icon appears and remains on in the Notification communicating with the DCS 30X, the icon, the 5020 is unable to communicate with the DCS 30X. See Tray. If you see a Chapter 4, “Troubleshooting and Maintenance,” for help.

3-8

Page 97

jjjj39

Connecting the 5020 helveticacondensed

3

Configuring for Serial or IrDA Communications The 5020 has an IrDA port for data communications with a host computer. To convert the IrDA port to an RS-232 serial port, you need an L5020 Serial Communications Adapter, a D5020 Communications Dock, or a serial input/output (I/O) PC card.

Locating the IrDA Port The 5020’s IrDA port is located on the end of the 5020 below the keypad.

IrDA port 5020U024.eps

5020 Data Collection PC in a Wired Network

Host

File server

5020 with L5020 Serial Communications Adapter Terminals Ethernet

PC

5020U080.eps

5020 in a D5020 Communications Dock

5020 with serial I/O PC card installed

3-9