5020 Data Collection PC User's Manual: Chapter 3: Connecting the 5020, pages 98 to 106

Pages 98 to 106 of 144, from 5020 Data Collection PC User's Manual

The original document is the PDF (2.0 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Intermec 5020

Page 98

5020 Data Collection PC User’s Manual

Helveticcond blk

39jjj

Before you can use the 5020 for serial or IrDA communications, you need to connect and configure the device. The next sections cover these topics: •

Connecting the 5020 to Another Device

•

Connecting With a Serial I/O Card

•

Configuring the Baud Rate

Once the 5020 is connected, you can use ActiveSync to establish a partnership between your desktop PC and the 5020 for browsing, file transfers, application development, and other device management activities. For help, see “Using ActiveSync” in Chapter 5 of the 502X system manual.

Connecting to Another Device You can physically connect the 5020 to another device using one of the methods described next. Either connect the Serial Communications Dock to a device (host computer, printer, or other serial device) using an RS-232 null-modem serial cable (Part No. 070268), or connect the IrDA Communications Dock to an IrDA transceiver using the IrDA port. Connect the power supply to the dock and then place the 5020 in the dock. You can transfer data between the 5020 and the device connected to the dock. For help, see the D5020 Communications Dock Getting Started Guide (Part No. 068976). D5020 IrDA and Serial Communications Docks

To device To power

5020U026.eps

3-10

Page 99

jjjj39

Connecting the 5020 helveticacondensed

3

Connect the serial adapter to a device (host computer, printer, or other serial device) using an RS-232 null-modem serial cable (Part No. 070268). Connect the power supply to the serial adapter. Install the serial adapter onto the IrDA port on the 5020. You can transfer data between the 5020 and the device connected to the serial adapter. For help, see the L5020 Serial Communications Adapter Quick Reference Guide (Part No. 068978). L5020 Serial Communications Adapter

To device To power supply

5020U049.eps

Install a serial I/O PC card in a batch 5020 and connect the cable from the serial PC card to a device (host computer, printer, or other serial device). You can transfer data between the 5020 and the device connected to the serial PC card. You may need to configure the 5020 baud rate (default of 115200) to match the serial PC card. Check the documentation that ships with your serial PC card. For help with installing PC cards, see “Using PC and Compact Flash Memory Cards” in Chapter 1. To configure the 5020 for use with a serial card, see “Connecting With a Serial I/O Card” later in this chapter. For help with changing the baud rate, see “Setting the Baud Rate” later in this chapter. Serial I/O PC Card (Batch 5020 only)

5020U079.eps

To device

3-11

Page 100

5020 Data Collection PC User’s Manual

Helveticcond blk

39jjj

Line up the IrDA port on the 5020 with the IrDA port on another 5020 or on a PC. The two IrDA ports must be within about 30.5 centimeters (1 foot) of each other. You do not need to set the IrDA baud rate because the two computers will auto-negotiate and choose the highest possible speed. 5020-to-5020 (or IrDA Port)

IrDA communications

5020U076.eps

Connecting With a Serial I/O Card (Batch 5020s only) Serial connections to the 5020 are enabled through the IrDA port by default. To enable a serial connection through a serial I/O card, you need to set up a new connection route. The next instructions explain how to configure a batch 5020 to communicate through a serial I/O card. After the 5020 has been configured in this manner, you can use ActiveSync to communicate with the host PC. For help with ActiveSync, see “Using ActiveSync” in Chapter 5 of the 502X system manual. After you have configured the 5020 to communicate through the serial I/O card, you can return the communications route to the IrDA port when needed. To do this, see “To select the IrDA port” later in this chapter. To configure a batch 5020 for use with a serial I/O card

1. Install the serial I/O card in the 5020. For help, see “Inserting and Removing PC Cards” in Chapter 1. 2. Press 3. Press

3-12

' to turn on the 5020. . The Start menu appears.

Page 101

jjjj39

&

4. Press

Connecting the 5020 helveticacondensed

3 to select Run and press . The Run dialog box appears.

&

5. Type REMNET and press . The Connection dialog box appears. Select the Make New Connection icon.

&

6. Press . The Make New Connection dialog box appears.

7. Enter a name for the new connection. When finished, press Connection.

3 to select Direct

3-13

Page 102

5020 Data Collection PC User’s Manual

Helveticcond blk

39jjj

3

&

8. Press to select the Next button and press . The Make New Direct Connection dialog box appears.

9. Press

! 3

& to select Socket I/O Serial from the drop-down list.

10. Press to select the Configure button and press . The Device Properties dialog box appears.

11. Press

& 3 to change the Baud Rate setting to 19200.

&

12. Press . The Make New Direct Connection screen appears. 13. Press

14. Press

3-14 to select the Finish button and press . The Connection screen appears.

"%

. The Task Manager screen appears.

Page 103

jjjj39

! %

! 9

3

Connecting the 5020 helveticacondensed

&

3

15. Press to select Connections. Press to select End Task and press . Connections disappears from the Task Manager list. 16. Press 17. Press 18. Press to close Task Manager. The 5020 desktop appears.

& to open the Start menu.

7

& to select Settings and press . The Control Panels desktop appears.

19. Press and then press to select the Communications icon. Press . The Communications Properties dialog box appears.

$3

20. Press appears.

3

& to select the PC Connection tab and press . The PC Connection tab

&

21. Press to select the Change button and press . The Change Connection dialog box appears.

3-15

Page 104

5020 Data Collection PC User’s Manual

Helveticcond blk

22. Press 23. Press 24. Press

39jjj

! & 3 "

& & to select your new connection and press .

again to return to the PC Connection tab.

!

& to select the Identification tab and press . The Control Panels desktop appears.

25. Press twice to open the File menu. Press desktop appears.

to select Close and press . The 5020

The 5020 is now set up to communicate through the serial I/O card. If you need to return the 5020 serial communications to the IrDA port, see the next section.

! 9

To select the IrDA port

1. Press 2. Press

& to open the Start menu.

7

& to select Settings and press . The Control Panels desktop appears.

3. Press and then press to select the Communications icon. Press . The Communications Properties dialog box appears.

$3

4. Press appears.

3-16

& to select the PC Connection tab and press . The PC Connection tab

Page 105

jjjj39

3

&

Connecting the 5020 helveticacondensed

3

5. Press to select the Change button and press . The Change Connection dialog box appears.

6. Press 7. Press 8. Press

& 3 "

& to select IrDA Port and press .

again to return to the PC Connection tab.

!

&

& to select the Identification tab and press . The Control Panels desktop appears.

9. Press twice to open the File menu. Press desktop appears.

to select Close and press . The 5020

The 5020 is now ready for serial connections through the IrDA port. Note: On a cold boot, any new connections made in REMNET are lost, and serial communications are reset to the IrDA port. You need to recreate any new serial connections after a cold boot. For help, see “To configure a batch 5020 for use with a serial I/O card” earlier in this chapter.

Setting the Baud Rate The baud rate you set for the 5020 IrDA port must match the baud rate set for the serial port on the connected device. You must connect the 5020 to a D5020 Communications Dock or an L5020 Serial Communications Adapter to set the IrDA baud rate. Set the baud rate using the Configuration application, the Configuration Management application in Unit Manager, SNMP, or Fast Config. To set the baud rate with the Configuration application

1. If the Configuration application is not open, open the Start menu. Choose Programs and then Configuration.

!

2. Open the Configure menu. 3. Press

& to select Unit and then press . The Unit configuration screen appears.

3-17

Page 106

5020 Data Collection PC User’s Manual

Helveticcond blk

39jjj

9

4. Press to select the Serial Port configuration tab and then press baud rate.

5. Press

3

3 and use the arrow keys to select the baud rate.

6. To save your changes, press

! '

9. Press to select the IrDA

& to select the Apply button and then press .

7. Exit the Configuration application. 8. Press

3

& to highlight Exit and then press . twice to have the changes take effect.

Once the 5020 is connected and configured, you are ready to connect and transfer data between the 5020 and the device that is connected to the IrDA or RS-232 serial port. You can use PC Connection to establish a serial connection, and then use ActiveSync to establish a partnership for file and application management. For help, see “Using ActiveSync” in Chapter 5 of the 502X system manual.

3-18