This chapter provides information to help solve problems while using your 5020. You will also find guidelines for booting the 5020, instructions for upgrading and restoring the operating system image, and a procedure for verifying RF communications.

Problems and Solutions If you have a problem while using the 5020, look in this chapter to find a possible solution. This chapter consists of the following sections: Sections

Page

Problems While Operating the 5020

4-4

Problems With Connectivity

4-6

Problems While Configuring the 5020

4-8

Problems While Using Unit Manager

4-9

Problems While Scanning Bar Codes

4-11

Problems Upgrading the Operating System Image

4-13

Application Manager Error Messages

4-14

Booting the 5020

4-14

Verifying RF or Ethernet Communications

4-16

Upgrading the 5020 Operating System Image

4-16

Restoring a Corrupted Operating System Image

4-17

Caution There are no user-serviceable parts inside the 5020. Opening the unit will void the warranty and may cause damage to the internal components. Conseil Le 5020 ne contient pas de pièces révisibles par l’utilisateur. Le fait d’ouvrir l’unité annule la garantie et peut endommager les pièces internes. If you send the 5020 in for service, it is your responsibility to save your data and configuration. Intermec is responsible only for ensuring that the keypad and other hardware features match the original configuration when repairing or replacing your 5020.

4-3

Page 110

5020 Data Collection PC User’s Manual nuggetf code39

Problems While Operating the 5020

'

Problem or Message

Solution

You press to turn on the 5020 and nothing happens.

Make sure you have a charged main battery pack installed in the 5020.

'

After placing the 5020 in storage, you press to turn on the 5020 and nothing happens.

'

The main battery pack has a low charge. Replace the main battery pack with a fully charged one. Press to turn on the 5020. A message saying that the main battery pack is low appears. The Power applet opens and the 1-minute low-power shutdown process has begun. The 5020 will turn off in one minute. To stop the 5020 from turning off and to clear the message, press and then press twice.

$" %3 3

%

'

While working with an application on the 5020, you open the Start menu and cannot close the Start menu.

Press to open the Task Manager. Select your application or press twice. For help, see “Switching Between Applications With Task Manager” in Chapter 1.

You added notes to the Owner Properties applet of the Control Panel, selected the Apply button, and pressed and nothing happened.

&

Press to put the focus on Notes and press . The Owner Properties applet saves the information and closes.

The 5020 is running slowly.

Remove any unnecessary programs. Use the Application Manager in Unit Manager to remove programs. For help, see “Uninstalling Applications” in Chapter 4 of the 502X Data Collection PC System Manual (Part No. 071479).

&

If the 5020 is still running slowly, increase the program memory. Use the System applet in the Control Panel to adjust the memory allocation. For help, see “Adjusting Memory Allocation” in Chapter 3 of the 502X system manual. The 5020 does not have enough storage memory to load a file.

Use the File Manager application in Unit Manager to delete unnecessary files. For help, see “Deleting a File” in Chapter 4 of the 502X system manual. If the 5020 still does not have enough storage memory, increase the storage memory. Use the System applet in the Control Panel to adjust the memory allocation. For help, see “Adjusting Memory Allocation” in Chapter 3 of the 502X system manual.

You hotswap a PC card, such as an Ethernet card, and the 5020 does not recognize the new card.

4-4

Warm boot the 5020. For help, see “Booting the 5020” later in this chapter.

Page 111

nuggetf code39

Troubleshooting and Maintenance

4

Problems While Operating the 5020 (continued)

Problem or Message

Solution

The 5020 beeps every 15 seconds, the Power applet starts, and the Main Battery Very Low message appears:

1.

Press

2.

Press

3.

Exit any running applications.

4.

Press

5.

Replace the main battery pack with a spare charged battery pack, charge the main battery pack, or attach an external power supply.

% % ' to close the message box. to close the Power applet.

to suspend the 5020.

For more information, see “Learning About the Batteries” in Chapter 1.

The Bridge Battery Very Low dialog box appears:

1. Press

& to close the message box.

2. Apply AC power to charge the bridge battery. The bridge battery will be fully charged in approximately 72 hours. Do not remove the main battery pack until the Power applet indicates the bridge battery has at least a 50% charge or data loss may occur. You can remove the 5020 from AC power after the main battery pack is charged. For more information, see “Charging the Bridge Battery” in Chapter 1.

Pressing the arrow keys has no effect on focus placement or the cursor.

"$

The pointer may have been turned on inadvertently. If the pointer icon is visible in the Notification Tray, press to turn off the pointer. When the pointer is enabled, the arrow keys move the pointer and have no effect on the cursor or on where the focus is placed.

4-5

Page 112

5020 Data Collection PC User’s Manual nuggetf code39

Problems With Connectivity Problem or Message

Solution

You see one of these messages:

If you turned on the 5020 for the first time, press or to exit the message box. If you are using a batch 5020 or do not have a DHCP server, disable DHCP. For help, see Chapter 3, “Connecting the 5020.”

& %

& %

If you are using an RF 5020 or have an Ethernet card installed and have a DHCP server, press or to exit the message box. For the RF 5020, make sure the Radio Connect icon ( ) is displayed in the Notification Tray. Make sure you are in range of an access point. Also make sure the radio parameters, such as RF security ID or domain, are set correctly. For help, see Chapter 3, “Connecting the 5020.” If you are upgrading the 5020 operating system image, do not press any keys, and wait for the message to disappear. The upgrade will continue. With DHCP enabled, you check the network parameters and they are incorrect.

In the Configuration application or in Unit Manager, click or choose the Refresh button in whatever screen you are at.

You have an RF 5020 and the Radio Not

The 5020 is unable to connect to an access point. Be sure that

Connected icon ( ) is displayed in the Notification Tray.

• the 5020 is within range of an access point.

• the access point has been turned on.

• the 5020 has been configured correctly. For help configuring the 5020, see Chapter 3, “Connecting the 5020.”

1.

Make sure the WINS or DNS network configuration is correct and that you have access to a WINS or DNS server.

2.

Exit eMbedded Visual Tools. Use Task Manager to verify that the CEMGR process is not running. End the process if it is running.

3.

Set up eMbedded Visual Tools for remote debugging.

While using eMbedded Visual Tools, you are unable to establish a connection to the 5020.

One of the Data Buffer icons blinks: Data buffered in Data buffered out Data buffered in and out No data is currently pending or the No UDP Connection icon appears:

4-6

There is a connection problem with a DCS 30X. Make sure the 5020 is in range of an access point and that the 5020 and DCS 30X are configured correctly. For help configuring for UDP Plus, see “Enabling UDP Plus” in Chapter 3.

Page 113

nuggetf code39

Troubleshooting and Maintenance

4

Problems With Connectivity (continued)

Problem or Message

Solution

The host communicates with the RF 5020 through an Intermec 011X access point and the host cannot initiate communications with the 5020.

To conserve battery life, the 5020 radio does not wake up on broadcast messages unless an access point with an address resolution protocol (ARP) server converts the multicast ARP request to a unicast request. The 011X access points do not provide ARP server support, so you must add a static entry in the host’s ARP table. To solve the problem, add the 5020’s IP address and MAC address to your host’s ARP table. You must disable DHCP before adding the 5020’s IP address to the ARP table. On a Windows 95, 98, or NT host, you can open an MS-DOS window and enter the following command: ARP –s IP_address MAC_address [IF_address] where: IP_address MAC_address IF_address is the 5020’s IP address. is the 5020’s MAC address. is the IP address for the ARP table. This part of the command is optional.

For a complete description of this command, enter the following at a DOS prompt at the host PC: ARP -? You cannot establish a partnership with ActiveSync.

You must connect the 5020 to your desktop PC through an L5020 Serial Communications Adapter or a D5020 Communications Dock, and then use PC Connection to establish a serial link between the 5020 and your desktop PC. Then you can establish a partnership through ActiveSync. For more information, see “Using ActiveSync” in Chapter 5 of the 502X system manual. On the 5020, PC Connection sets a baud rate of 19200 when first establishing an ActiveSync partnership. If you change the 5020 baud rate setting after a partnership has been established, it may take several connection attempts before ActiveSync can automatically match the desktop PC to the new baud rate. After the connection is made at the new baud rate, this becomes the default ActiveSync baud rate.

You have an Ethernet PC card installed but the Ethernet tab does not appear in the Network menu of the Configuration application or the Configuration Management application in Unit Manager.

Warm boot the 5020 to initialize the PC card then restart the Configuration application or Unit Manager. For help, see “Warm Booting the 5020” later in this chapter.

4-7

Page 114

5020 Data Collection PC User’s Manual nuggetf code39

Problems While Configuring the 5020 Problem or Message

Solution

You changed the radio, Ethernet, or UDP Plus parameters, such as DHCP enable or the 5020 IP address, but the parameters did not take effect on the 5020.

Press twice to suspend and resume the 5020 and have the changes take effect.

You enabled or disabled UDP Plus but the change did not take effect on the 5020.

Warm boot the 5020 to enable the change. For help, see “Warm Booting the 5020” later in this chapter.

While using Fast Config to set up the 5020, this message appeared:

If the 5020 is not connected to a D5020 Communications Dock or an L5020 Serial Communications Adapter, you can set all parameters except the baud rate. Press to clear the message. The Communications screen appears without a baud rate selected. Press to continue using Fast Config.

'

If you have DHCP enabled and the DHCP-assigned parameters are not displayed, select the Refresh button in the Configuration application or Configuration Management.

&

'&

&

%

If the 5020 is connected to a D5020 or an L5020 and you see this message, press to clear the message. Press to close Fast Config, and then press twice to turn the 5020 off and back on. After warm or cold booting the 5020, you chose Data Collection from the Configure menu in the Configuration application or Configuration Management, and some or all of the parameters do not display or show as Not Available.

You may not have waited for the warm or cold boot to finish before you opened the Configuration application. Choose Refresh to refresh the parameters. On a cold boot, wait until the beep sequence (three high beeps and one low beep) sounds and the red LED stops flashing before you open any applications.

You try to configure the 5020 using SNMP and SNMP does not work.

Check community strings, IP addresses, and whether encryption is turned on or off. If encryption is on, turn it off. (SNMP encryption only works with Intermec software that supports it.) For help, see “Configuring the 502X by Using SNMP” in Chapter 2 of the 502X system manual.

You scan a configuration command, such as Beep Volume Very Quiet, and nothing happens.

There are two possible solutions:

4-8

•

If the Configuration application is open, you cannot scan configuration commands. Use the Configure menu to change the 5020’s configuration, or exit the Configuration application to scan configuration commands.

•

The 5020 may be waiting for another command to complete the configuration change. If you started by scanning the Enter Accumulate command, you must finish the command by scanning the Exit Accumulate command. For help, see Chapter 7, “Configuration Command Reference,” in the 502X system manual.

Page 115

nuggetf code39

Troubleshooting and Maintenance

4

Problems While Configuring the 5020 (continued)

Problem or Message

Solution

You scan a configuration command, such as Beep Duration, and you hear three low beeps.

You scanned an invalid configuration command. Make sure the variable (data) part of the command is valid for that command. For example, the beep duration cannot be lower than 10 ms, so the following configuration, which would set the duration to 5 ms, would be invalid. Invalid Beep Duration (5 ms)

*$+BB5*

*$+BB5*

Problems While Using Unit Manager Problem or Message

Solution

You enter the 5020 IP address in your Web browser and you get a message that your browser cannot connect.

Try these solutions: •

If your network uses a proxy server, the 5020 IP address must be added to the proxy exceptions list. Add the IP address to the proxy exceptions list and try again.

•

The 5020 may be off. Turn on the 5020 and either disable automatic shutoff or connect AC power through the D5020 or the L5020.

•

Make sure that ITCRB.EXE (deviceWEB) is running. Look for the rainbow icon ( ) in the Notification Tray.

•

If you have an RF 5020, you may be out of range of an access point. Make sure the 5020 is on and connected to an access point.

•

If you are using an Ethernet PC card, make sure you have the 5020 configured correctly for your network.

•

Warm boot the 5020.

In the Configuration Management application in Unit Manager, the Web browser locks up when you press Tab to move out of a field.

You did not complete the entry for the field you just left, such as the IP address field. Close the browser, re-open it and start Unit Manager. Make sure you enter all of the data for a field before moving to a different field.

You are in Unit Manager and the Web browser screen goes blank or becomes jumbled.

The 5020 may have suspended or been turned off. Make sure the 5020 is on and remains on. If you have an RF 5020, you may be out of range. Make sure the 5020 is on and connected to an access point. If the 5020 has not been suspended or turned off, make sure your Web server is still on.

4-9