The text of a manual · part 6 of 9
MaxiScan 3300 Installation Guide, pages 51 to 60
Pages 51 to 60 of 82
The original document is the PDF (650 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 3300
Page 51
B. MaxiScan 3300 cable connector RS-422 RS-422: install resistor = 100 Ohm I/O sync max current 50 mA SO- SO+
SI-
SI+
TX+
RX+
TX- RX1
2
9 8
7
6
5
4
3
2
3
10
4
11
5
12
13
6
7
14
15
8
1 host male subD cable connector 15
NC
14
13
12
11
10
SHIELD 7-25 GND VDC
GND
9
NC 7-25 VDC both 7-25 VDC power supply pins must be powered both GND pins must be used
MaxiScan 3300 15-pin subD female connector pin function
1 receive data RX- (RS-422)
2 transmit data TX- (RS-422)
3 receive data RX+ (RS-422)
4 transmit data TX+ (RS-422)
5 positive synchronization input (SI+)
6 negative synchronization input (SI-)
7 positive synchronization output (SO+)
8 negative synchronization output (SO-)
9 not connected
10 power in (7 to 25 VDC 10 Watt unregulated)
11 power ground
12 shield
13 power ground
14 power in (7 to 25 VDC 10 Watt unregulated)
15 not connected
MS/3300/IG/10/E/970831
B-3
Page 52
B. MaxiScan 3300 cable connector RS-485 RS-485: connect pins 1 and 2 and connect pins 3 and 4 install resistor = 120 Ohm between pins 1 and 3 I/O sync max current 50 mA SO- SO+
SI-
SI+
TX+
RX+
TX- RX1
2
9 8
7
6
5
4
3
2
3
10
4
11
5
12
13
6
7
14
15
8
1 host male subD cable connector 15
NC
14
13
12
11
10
SHIELD 7-25 GND VDC
GND
9
NC 7-25 VDC both 7-25 VDC power supply pins must be powered both GND pins must be used
MaxiScan 3300 15-pin subD female connector pin
B-4 function
1 receive / transmit data RX- / TX- (RS-485)
2 receive / transmit data RX- / TX- (RS-485)
3 receive / transmit data RX+ / TX+ (RS-485)
4 receive / transmit data RX+ / TX+ (RS-485)
5 positive synchronization input (SI+)
6 negative synchronization input (SI-)
7 positive synchronization output (SO+)
8 negative synchronization output (SO-)
9 not connected
10 power in (7 to 25 VDC 10 Watt unregulated)
11 power ground
12 shield
13 power ground
14 power in (7 to 25 VDC 10 Watt unregulated)
15 not connected
MS/3300/IG/10/E/970831
Page 53
C
MaxiScan Connexion System (MCS)
port type connection remarks
SCANNER
15-pin subD male
MaxiScan 3300
-
POWER SUPPLY 7-25 V
9-pin subD male external power supply
7-25 V 10 Watt full-wave rectified unregulated power
HOST
15-pin subD female host computer
• RS-232 C (standard configuration) • RS-422 • RS-485 • Current Loop (requires MCS) each host system interface is software programmable and requires a different cable
SYNCHROS
9-pin subD female
I/O synchronization cable
• input synchronization - reading can be triggered by an external cell, automatic machine, electrical control device • output synchronization - an external device (switch, alarm, indicator light) can be triggered by a good read or unsuccessful read as required
MS/3300/IG/10/E/970831
C-1
Page 54
C. MaxiScan Connexion System (MCS) SCANNER port RS-232 C
RX
TX
CTS
RTS
RS-422 / 485
RX-
TX-
RX+
TX+
1
2
3
4
9
10
11
12
SI+
SI-
SO+
SO-
5
6
7
8
13
14
15
CHASSIS GND 7-25 VDC
PWR GND
7-25 VDC
15-pin subD male connector pin
C-2 function
1 receive data (RS-232 C) / RX- (RS-422 / 485)
2 transmit data (RS-232 C) / TX- (RS-422 / 485)
3 clear to send (RS-232 C) / RX+ (RS-422 / 485)
4 request to send (RS-232 C) / TX+ (RS-422 / 485)
5 positive synchronization input (SI+)
6 negative synchronization input (SI-)
7 positive synchronization output (SO+)
8 negative synchronization output (SO-)
9 not connected
10 power in (7 to 25 VDC 10 Watt unregulated)
11 power ground
12 shield
13 power ground
14 power in (7 to 25 VDC 10 Watt unregulated))
15 not connected
MS/3300/IG/10/E/970831
Page 55
C. MaxiScan Connexion System (MCS) POWER SUPPLY 7-25V port 7-25 VDC (2 wires)
1
2
6
GND (2 wires)
3
7
4
8
5
9
9-pin subD male connector pin function
1 power in (7 to 25 VDC 10 Watt unregulated)
2 power in (7 to 25 VDC 10 Watt unregulated)
3 not connected
4 not connected
5 not connected
6 not connected
7 not connected
8 power ground
9 power ground
MS/3300/IG/10/E/970831
C-3
Page 56
C. MaxiScan Connexion System (MCS) HOST port - RS-232 C RTS
CTS
TX
RX
4
3
2
1
GND
8
7
15
6
14
5
13
12
11
10
9
MCS 15-pin subD female connector pin
C-4 function
1 receive data (RS-232 C)
2 transmit data (RS-232 C)
3 clear to send (RS-232 C)
4 request to send (RS-232 C)
5 not connected
6 not connected
7 not connected
8 not connected
9 not connected
10 reserved Current Loop
11 reserved Current Loop
12 reserved Current Loop
13 signal ground (RS-232 C)
14 reserved Current Loop
15 reserved Current Loop
MS/3300/IG/10/E/970831
Page 57
C. MaxiScan Connexion System (MCS) HOST port - RS-422 RS-422: install resistor = 100 Ohm
TX+
RX+
TX-
RX-
GND
1
2
9 8
7
6
5
4
3
2
3
10
4
11
5
12
13
6
7
14
15
8
1 host male subD cable connector 15
14
13
12
11
10
9
MCS 15-pin subD female connector pin
MS/3300/IG/10/E/970831 function
1 receive data RX- (RS-422)
2 transmit data TX- (RS-422)
3 receive data RX+ (RS-422)
4 transmit data TX+ (RS-422)
5 not connected
6 not connected
7 not connected
8 not connected
9 not connected
10 reserved Current Loop
11 reserved Current Loop
12 reserved Current Loop
13 signal ground (RS-422)
14 reserved Current Loop
15 reserved Current Loop
C-5
Page 58
C. MaxiScan Connexion System (MCS) HOST port - RS-485 RS-485: connect pins 1 and 2 and connect pins 3 and 4 install resistor = 120 Ohm between pins 1 and 3
TX+
RX+
TX-
RX-
GND
1
2
9 8
7
6
5
4
3
2
3
10
4
11
5
12
13
6
7
14
15
8
1 host male subD cable connector 15
14
13
12
11
10
9
MCS 15-pin subD female connector pin
C-6 function
1 receive / transmit data RX- / TX- (RS-485)
2 receive / transmit data RX- / TX- (RS-485)
3 receive / transmit data RX+ / TX+ (RS-485)
4 receive / transmit data RX+ / TX+ (RS-485)
5 not connected
6 not connected
7 not connected
8 not connected
9 not connected
10 reserved Current Loop
11 reserved Current Loop
12 reserved Current Loop
13 signal ground (RS-485)
14 reserved Current Loop
15 reserved Current Loop
MS/3300/IG/10/E/970831
Page 59
C. MaxiScan Connexion System (MCS) HOST port - Current Loop (passive type) Current Loop: connect pins 1 and 10
RX-
RX+
TX-
TX+
GND
1
2
9 8
7
6
5
4
3
2
3
10
4
11
5
12
13
6
7
14
15
8
1 host male subD cable connector 15
14
13
12
11
10
9
MCS 15-pin subD female connector pin
MS/3300/IG/10/E/970831 function
1 reserved
2 reserved RS-232 C / RS-422 / 485
3 reserved RS-232 C / RS-422 / 485
4 reserved RS-232 C / RS-422 / 485
5 not connected
6 not connected
7 not connected
8 not connected
9 not connected
10 reserved
11
TX+ (Current Loop)
12
TX- (Current Loop)
13 signal ground (Current Loop)
14
RX+ (Current Loop)
15
RX- (Current Loop)
C-7
Page 60
C. MaxiScan Connexion System (MCS) SYNCHROS port In all cases, the synchronization current provided by the external input/output device must be limited to 50 mA max (20 mA is a good average value). SI-
SI+
SO-
SO+ +5V 7-25V pwr
GND
5
4
9
3
8
2
7
1
6
9-pin subD female connector pin
C-8 function
1
+5 VDC out (65 mA max)
2 positive synchronization output (SO+) (50 mA max )
3 negative synchronization output (SO-) (50 mA max)
4 positive synchronization input (SI+) (50 mA max)
5 negative synchronization input (SI-) (50 mA max)
6
7-25 VDC 10 Watt
7 not connected
8 not connected
9 power ground
MS/3300/IG/10/E/970831