MaxiScan 3300 Installation Guide, pages 61 to 70

Pages 61 to 70 of 82

The original document is the PDF (650 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Intermec 3300

Page 61

D

Standard RS-232 C cable cable connector - 15-pin subD male MaxiScan Connexion System side

1

2

9 RX

3

10 TX

4

11

5

12

CTS

6

13

7

14

8

15

RTS GND

RS-232 C shielded cable (shielding connected to casing of cable connectors)

5

4

9

3

8

2

7

1

6 cable connector - 9-pin subD female PC side DB 15 male MaxiScan Connexion System side signal

DB 9 female PC side

1

RX

3

2

TX

2

3

CTS

7

4

RTS

8

11-13

GND

5 connector casing shielding connector casing

MS/3300/IG/10/E/970831

D-1

Page 62

D. Standard RS-232 C cable

D-2

MS/3300/IG/10/E/970831

Page 63

E

Input/output synchronization

Input synchronization - Hardware MaxiScan 3300 trigger event current on the MaxiScan 3300 starts to read when current flows between inputs SI+ and SI- and remains active until the current stops flowing current off the MaxiScan 3300 starts to read when no current flows between inputs SI+ and SI- and remains active until current starts to flow input pulse the MaxiScan 3300 starts to read for a programmable duration when a change-of-state pulse is received through the SYNCHROS input

Output synchronization - Hardware Hardware synchronization Output device trigger event good read the output device is activated after a good read no read the output device is activated if there is no successful read during an input synchronization reading session triggered by an input pulse (no read before the end of the read time-out)

Output device activation current current on the MaxiScan 3300 allows current to flow between outputs SO+ and SO-current off the MaxiScan 3300 allows no current to flow between outputs SO+ and SO-

Output synchronization - Software The MaxiScan 3300 can send a message to the host system after a read success or failure.

MS/3300/IG/10/E/970831

E-1

Page 64

E. Input/output synchronization Synchronization flowchart yes current flow type of trigger event hardware sync in no input pulse

Select activation: • current on • current off

Compose read duration yes hardware sync out no

Select activation: • current on • current off Compose active duration no read no hardware sync in

Select trigger event good read yes yes software sync out no

Compose message for host system no read no hardware sync in

Select trigger event good read yes

Test synchronization setup

E-2

MS/3300/IG/10/E/970831

Page 65

E. Input/output synchronization Examples Input synchronization - Direct connection Example: Reading triggered by an opto-coupled MLV 40-8/28 (VISOLUX) cell.

R =

V power supply -3

20.10

Ω

1

5 photoelectric sensor 7-25 VDC power supply

8

7

15

SI-

SI+

6

5

14

13

MaxiScan 3300 15-pin subD female connector

4

12

3

11

2

10 GND

4

1

9

MaxiScan 3300

In all cases, the synchronization current provided by the external input device must be limited to 50 mA max (20 mA is a good average value).

MS/3300/IG/10/E/970831

E-3

Page 66

E. Input/output synchronization Output synchronization - Direct connection Example: Opto-coupled control output.

conveyor command block

SO- SO+

8

7

15

6

14

5

13

4

12

3

11

2

10

MaxiScan 3300 15-pin subD female connector

1

9

MaxiScan 3300

The synchronization current provided by the external output device must be limited to 50 mA max (20 mA is a good average value).

E-4

MS/3300/IG/10/E/970831

Page 67

E. Input/output synchronization Input synchronization - MCS connection unit Example: Reading triggered by an opto-coupled MLV 40-8/28 (VISOLUX) cell.

330 Ohms 1

5 photoelectric sensor 4 GND 7-25 VDC power supply SI-

SI+

5

4

9

+5V (65 mA max)

3

8

2

7

1

6

MaxiScan Connexion System SYNCHROS 9-pin subD female connector

In all cases, the synchronization current provided by the external input device must be limited to 50 mA max (20 mA is a good average value).

MS/3300/IG/10/E/970831

E-5

Page 68

E. Input/output synchronization Output synchronization - MCS connection unit Example: Opto-coupled control output.

conveyor command block

7-25 VDC power supply

GND

5

SO- SO+

4

9

3

8

SYNCHROS 9-pin subD female connector

+5V (65 mA max)

2

7

1

6

MaxiScan Connexion System

The synchronization current provided by the external output device must be limited to 50 mA max (20 mA is a good average value).

E-6

MS/3300/IG/10/E/970831

Page 69

F

If you have a problem . . .

This appendix describes things you can try if you have problems with your MaxiScan 3300 during power-up, configuration and normal operation. If you can not solve the problem yourself, please contact your UBI representative.

Before you contact your UBI representative . . . Look in the following checklists if you have any of the following problems: • no LEDs

• no beeps

• error beeps

• no transmission

• incorrect transmission

Setup problems - Checklist system connected up correctly system switched on correct power-up beep indication - 2 beeps default configuration inhibit after 1 minute option is active - if you are using a setup sheet, you must switch off / switch on the MaxiScan 3300 to be able to read configuration codes if the 1-minute configuration timeout has expired

MS/3300/IG/10/E/970831

F-1

Page 70

F. If you have a problem . . . Reading problems - Checklist correct symbologies selected for the bar codes you are trying to read symbologies you read are available for your MaxiScan 3300 all unnecessary symbologies disabled continuous configuration mode disabled (configuration inhibit after 1 minute selected) barcode length compatible with minimum / fixed length parameter settings of MaxiScan 3300 MaxiScan 3300 configured for check digit and no check digit present in code barcode quality, damaged or poorly printed codes, "fragile" symbologies - read the appropriate test code to see if there is a problem with the symbology (Appendix G)

Transmission problems - Checklist all unnecessary symbologies disabled continuous configuration mode disabled (configuration inhibit after 1 minute selected) correct RS-232 data transmission settings selected inter-character delay value required if transmitted data incomplete or incorrect

F-2

MS/3300/IG/10/E/970831