The text of a manual · part 5 of 9
MaxiScan 3300 Installation Guide, pages 41 to 50
Pages 41 to 50 of 82
The original document is the PDF (650 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 3300
Page 41
A. Technical characteristics mounting
• metric screw threads under case • can be mounted in any position connector
15-pin subD
Environmental characteristics operating temperature
• 0° to 50° C (32° to 122° F) • use thermo-cooler for temperatures > 27° C • use thermo-cooler and input sync device for temperatures > 40° C storage temperature
-40° to 70° C (-40° to 158° F)
sealing standards (dust, corrosive chemicals)
IP65 / Nema 12 relative humidity
5% to 95% non-condensing maximum ambient lighting
4 000 lux on the code electrostatic discharge
8 kV to any external surface vibration
IEC 6826 - Fc shock
IEC 68227 - Ea
CE standards conformity
• Emission: EN 50081-2 (1995), EN 55022 (1987) Class A • Immunity: EN 50082-2 (1995) • Safety:
MTBF
EN 60950 (1993) / IEC 950
20 000 hours according to operating conditions
User interface power-up red LED - 2 beeps good read
1 green LED flash - 1 beep configuration error
6 error beeps
MS/3300/IG/10/E/970831
A-3
Page 42
A. Technical characteristics Dimensions MaxiScan 3300
100 mm (3.9")
75 mm (2.9")
82 mm (3.2") 14 mm (0.5")
30 mm (1.2")
Scale: ½
38 mm (1.5")
A-4
MS/3300/IG/10/E/970831
Page 43
A. Technical characteristics Maxiscan Connexion System (external unit)
30 mm (1.18")
113 mm (4.45")
70 mm (2.76")
Scale: 1
MS/3300/IG/10/E/970831
A-5
Page 44
A. Technical characteristics Mounting points / laser light plane 30 mm (1.2")
38 mm (1.5")
82 mm (3.2")
75 mm (2.9")
100 mm (3.9")
30°
14 mm (0.5")
Scale: ¼
40°
A-6
MS/3300/IG/10/E/970831
Page 45
A. Technical characteristics Optional adjustable stand
4 x Ø4
4 x M4 5 mm (0.2") depth
30 mm (1.18")
38 mm (1.5")
92.5 mm (3.64") 52 mm (2.01")
52 mm (2.01")
Scale:
MS/3300/IG/10/E/970831
A-7
Page 46
A. Technical characteristics Horizontal scan width / reading distance / barcode density MaxiScan 3300 ST 9.8" 700
650
7.9"
5.9"
3.9"
2"
0"
2"
3.9"
5.9"
7.9"
9.8" 27.6"
The chart shows the horizontal reading range (top view) of the MaxiScan 3300 ST. The values shown are for high-contrast Code 39 with a ratio of 1:3 and correspond to the product default settings - increased performance is possible with specific configuration setups.
25.6"
23.6"
600 1.0 mm (40 mil) 550
21.7"
500
19.7"
450
17.7"
0.5 mm (20 mil)
15.7"
400
350
13.8"
0.3 mm (12 mil)
11.8"
300 0.2 mm (8 mil) 250
9.8"
200
7.9"
150
5.9"
3.9"
100
Scale: 2"
50
0 mm 250
A-8
0" 200
150
100
50
0
50
100
150
200
250
MS/3300/IG/10/E/970831
Page 47
A. Technical characteristics Horizontal scan width / reading distance / barcode density MaxiScan 3300 HR 3.9" 280
260
3.1"
2.4"
1.6"
0.8"
0"
0.8"
1.6"
2.4"
3.1"
3.9" 11.0"
The chart shows the horizontal reading range (top view) of the MaxiScan 3300 HR for high density codes. The values shown are for high-contrast Code 39 with a ratio of 1:3 and correspond to the product default settings - increased performance is possible with specific configuration setups.
10.2"
240
9.4"
220
8.7" 0.3 mm (12 mil) 7.9"
200 0.2 mm (8 mil)
180
7.1"
0.15 mm (6 mil) 6.3"
160 0.125 mm (5 mil)
140
5.5"
4.7"
120 0.1 mm (4 mil) 100
3.9"
80
3.1"
60
2.4"
1.6"
40
Scale: ½ 0.8"
20
0"
0 mm 100
80
MS/3300/IG/10/E/970831
60
40
20
0
20
40
60
80
100
A-9
Page 48
A. Technical characteristics
A-10
MS/3300/IG/10/E/970831
Page 49
B
MaxiScan 3300 cable connector SO- SO+
SI-
SI+
8
6
5
7
15
14
13
NC
RTS CTS
TX
TX+
RX+
TX- RX- RS-422 / 485
4
3
2
12
11
10
SHIELD 7-25 VDC
GND
RX
1
9
NC
GND
RS-232 C
7-25 VDC both 7-25 VDC power supply pins must be powered both GND pins must be used
15-pin subD female connector pin function
1 receive data (RS-232 C) / RX- (RS-422 / 485)
2 transmit data (RS-232 C) / TX- (RS-422 / 485)
3 clear to send (RS-232 C) / RX+ (RS-422 / 485)
4 request to send (RS-232 C) / TX+ (RS-422 / 485)
5 positive synchronization input (SI+)
6 negative synchronization input (SI-)
7 positive synchronization output (SO+)
8 negative synchronization output (SO-)
9 not connected
10 power in (7 to 25 VDC 10 Watt unregulated)
11 power ground
12 shield
13 power ground
14 power in (7 to 25 VDC 10 Watt unregulated)
15 not connected
MS/3300/IG/10/E/970831
B-1
Page 50
B. MaxiScan 3300 cable connector RS-232 C I/O sync max current 50 mA SO- SO+
SI-
SI+
RTS CTS
TX
RX
8
6
5
4
2
1
7
15
14
13
NC
12
3
11
10
SHIELD 7-25 VDC
GND
9
NC
GND
7-25 VDC both 7-25 VDC power supply pins must be powered both GND pins must be used
15-pin subD female connector pin
B-2 function
1 receive data (RS-232 C)
2 transmit data (RS-232 C)
3 clear to send (RS-232 C)
4 request to send (RS-232 C)
5 positive synchronization input (SI+)
6 negative synchronization input (SI-)
7 positive synchronization output (SO+)
8 negative synchronization output (SO-)
9 not connected
10 power in (7 to 25 VDC 10 Watt unregulated)
11 power ground
12 shield
13 power ground
14 power in (7 to 25 VDC 10 Watt unregulated)
15 not connected
MS/3300/IG/10/E/970831