The text of a manual · part 4 of 9
MaxiScan 3300 Installation Guide, pages 31 to 40
Pages 31 to 40 of 82
The original document is the PDF (650 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 3300
Page 31
5. Setting up your MaxiScan 3300 4. Customize your product operating settings
1. Select the settings you need if they are not already selected by default - double-click the selected commands or click the vertical command button. Choosing the right operating settings is very important for optimized reading performance ! This is especially true for the following parameters.
scan patterns • single line
• picket fence and ladder reading • set scan rate / position (scan width depends on reading distance) • picket fence - increase scan width to increase the number of scans • ladder - limit scan width to just over width of code if possible to avoid wasted scans
• raster
• picket fence only - do not use for ladder reading ! • good for poor quality or damaged labels (read same code at different heights) or variable label position • useful for multicode applications • set scan rate / sweep angle (scan area depends on reading distance and sweep angle) • limit raster or pattern to height of code if possible to avoid wasted scans
• lissajous curves
• undefined orientation • more directions = lower effective scan rate per line
• multipattern sequence
• for variable orientation and position • suitable for static reading or slow pass-through applications • cross pattern provides good coverage with codes that are higher than wide
• scan rate
MS/3300/IG/10/E/970831
• increase the scan rate if your application uses small bar codes and higher pass-through speeds
5-9
Page 32
5. Setting up your MaxiScan 3300 contrast level • all contrast levels
• cycles through all contrast levels for labels with varying contrast • OK when presenting labels, not good for passthrough applications • reading is slower than with dedicated contrast levels - use dedicated contrast levels (low, medium, high) if possible
• low contrast
• medium contrast
• high contrast
5-10
MS/3300/IG/10/E/970831
Page 33
5. Setting up your MaxiScan 3300 resolution adjustment (video channel selection) • high / low resolution
• continuous switching between the 2 video channels - the video channel changes with each new scan • normal-quality medium-resolution bar codes such as standard EAN (100%) are read easily by both video channels • reading is slower than with dedicated resolution levels - use dedicated resolution levels (high, low) if possible
• high resolution
• low resolution
MS/3300/IG/10/E/970831
5-11
Page 34
5. Setting up your MaxiScan 3300 data decoding security • timeout between identical consecutive codes
• prevents reading the same bar code more than once
• timeout between different consecutive codes
• prevents unwanted reading of other bar codes on the same label • longer timeout = slower reading of different codes
2. Click the next-step button to go on to the next step.
5-12
MS/3300/IG/10/E/970831
Page 35
5. Setting up your MaxiScan 3300 5. Configuration modes and utilities
The configuration inhibit after 1 minute option protects against unwanted reading of configuration codes and greatly improves reading performance for the "normal" bar codes in your application. If you use a setup sheet for configuration and the configuration inhibit after 1 minute option is selected, you must disconnect and then reconnect the MaxiScan 3300 power supply to enable reading of configuration codes. You then have 1 minute to read a setup code (if you do not read a code within 1 minute, the MaxiScan 3300 will leave configuration mode and you will have to switch off and restart the MaxiScan 3300 again). Every new configuration code you read enables the MaxiScan 3300 to read another configuration code within 1 minute. You have now created a setup for your MaxiScan 3300. Choose File - Save as if you want to save your setup sheet (the filename you give must have the extension .cfg).
MS/3300/IG/10/E/970831
5-13
Page 36
5. Setting up your MaxiScan 3300 Editing and printing out the setup sheet You may want to use the setup sheet for a number of reasons: • you did not choose to download the setup commands directly to the MaxiScan 3300, • you want to use the same setup for other MaxiScan 3300 units installed on your site, • you want to keep a record on paper of your setup. If the "configuration inhibit after 1 minute" option is selected, you must disconnect and then reconnect the MaxiScan 3300 power supply to enable reading of the configuration codes on the setup sheet (repeated 1-minute cycle).
1. Choose Edit - Concatenate if you want to reduce the number of codes you have to read with the MaxiScan 3300. 2. Choose Edit - Title if you want to give a title to your setup sheet. 3. Choose File - Print if you want to print out your setup sheet. concatenated configuration codes
5-14 title setup sheet
MS/3300/IG/10/E/970831
Page 37
5. Setting up your MaxiScan 3300 Sending commands from the setup sheet 1. Connect the standard RS-232 C cable between the HOST port of the MaxiScan Connexion System and the serial port of your PC if it is not already connected. 2. Choose Reader - Configure communication PC/Reader and select the Port the MaxiScan 3300 is connected to. 3. Click SelfSet. The software adapts the RS-232 communication parameters of your PC to the current settings of the MaxiScan 3300. 4. Select a command title in the setup sheet and click the Send selected command icon to send the command to the MaxiScan 3300. The Send all commands icon sends all the commands in the setup sheet to the MaxiScan 3300. Send selected command / Send all commands icons setup sheet selected command
MS/3300/IG/10/E/970831
5-15
Page 38
5. Setting up your MaxiScan 3300
5-16
MS/3300/IG/10/E/970831
Page 39
A
Technical characteristics
Technical characteristics are subject to change without prior notice due to continuous product improvement.
Models MaxiScan 3300 ST standard model
MaxiScan 3300 HR high resolution option laser diode thermocooler - required if ambient temperature above 27°C (80°F)
accessories
• MaxiScan Connexion System connection unit • mains power supply adapter (15 VDC, 0.65 A, 10 Watt full-wave rectified unregulated) • adjustable stand
Interface capability host system interfaces
• RS-232 C (standard configuration) • RS-422 • RS-485 • Current Loop (passive type)–requires MCS connection unit
I/O synchronization
• input sync from external device (opto-switch, . . .) • output sync to external device (conveyor gate switch, . . .) • software output to host system
Decoding capability symbologies
MS/3300/IG/10/E/970831
• Codabar • Codablock • Code 39 • Code 93 • Code 128 • EAN 128 • Industrial / Standard 2 of 5 • Interleaved 2 of 5 • Matrix 2 of 5
A-1
Page 40
A. Technical characteristics • MSI Code • Plessey Code • UPC/EAN • others on request code reconstruction decoding rate other decoding features
• optional for EAN-13, UPC-A • automatic with 1 fixed length selected for Code 39, CIP 128, Codabar CLSI, MSI Code, Plessey Code real-time with scanning rate if only 1 or 2 symbologies are selected • multicode reading • code sorting • autodiscrimination of symbologies
Scanning performance scan rate
• 400 to 700 scans/second • 450 scans/second at 40° scan angle (default)
maximum scan angle (scan width)
45° ± 4° maximum sweep angle (raster height)
adjustable increments to 30° ± 4° reading distance / depth of field see charts in next section pitch
± 70° skew
± 40° minimum print contrast ratio
25 % minimum resolution
• ST: • HR:
0.19 mm (7 mil) 0.08 mm (3 mil)
Optical characteristics light source
5 mW long-life red laser diode wavelength
660 nm laser class
US CDRH Class II, IEC Class 2
Electrical characteristics power supply voltage
7-25 VDC full-wave rectified unregulated power requirements
• < 3.5 Watt normal operation (higher peaks at power-up) • < 4.75 Watt with thermo-cooler (higher peaks at power-up)
Physical characteristics dimensions (width x depth x height)
82 x 75 x 100 mm (3.2 x 2.9 x 3.9")
maximum weight without cord
550 g (19.4 oz)
case
Epoxy-coated aluminium
A-2
MS/3300/IG/10/E/970831