Page 21

4

Power up the MaxiScan 3300

Laser safety recommendations The MaxiScan 3300 will operate in complete safety when used as specified in this Installation Guide. As for all laser products, avoid staring directly into the laser light beam for long periods of time - prolonged viewing into direct laser light may damage your eyes. Do not try to dismount the MaxiScan 3300 and always use the scanner only as described in official MaxiScan 3300 documentation.

Plug in and power up 1. Plug the external power supply into the mains socket. 2. Switch on the host system.

red power-up LED comes on

MS/3300/IG/10/E/970831

<beep> <beep>

4-1

Page 22

4. Power up the MaxiScan 3300 Beeps and LEDs Using EasySet System software or reading configuration bar codes green indicator LED flashes

<beep> <beep> = GOOD READ

<beep> <beep> <beep> <beep> <beep> <beep> = SETUP ERROR

Reading "normal" bar codes green indicator LED flashes

<beep> = GOOD READ no beep = NO READ / NO TRANSMISSION

4-2

MS/3300/IG/10/E/970831

Page 23

5

Setting up your MaxiScan 3300

Modifying your setup parameters The MaxiScan 3300 is pre-programmed with a set of factory default parameter settings, but you may need to modify some of the settings to suit your application. You can use the EasySet System configuration software to download your custom settings directly to the MaxiScan 3300 or print out the corresponding configuration bar codes. You can also use the host system to set up the MaxiScan 3300 dynamically according to your application.

Install and start up EasySet System The minimum configuration for the EasySet System configuration software is Windows™ 3.11 running on a 486 PC with 8 MB RAM.

1. Open the EasySet directory on your product cd-rom or diskette. 2. Double-click the setup.exe file to install the EasySet System configuration software on your PC. 3. Double-click the EasySet icon from the Windows™ program manager to start up EasySet.

MS/3300/IG/00/E/970630

5-1

Page 24

5. Setting up your MaxiScan 3300 Step-by-step mode EasySet starts up in Step-by-step mode - the Step-by-step mode checkbox is selected and the commands window shows the command for the first step. next-step button vertical command button commands window

Step-by-step mode checkbox

Step-by-step mode ensures that new users do not miss any steps during setup. When you have completed a step, click the next-step button to go on to the next step. Experienced users can deselect the Step-by-step mode checkbox for direct access to all the setup commands.

5-2

MS/3300/IG/00/E/970630

Page 25

5. Setting up your MaxiScan 3300 Using the commands window The setup commands in the commands window are presented in numbered sections corresponding to the different steps in a setup session. Each section is organized as a tree structure and uses the following symbols:

a closed branch with more information underneath - double-click on the corresponding line to open the branch and see more an open branch - double-click on the corresponding line to close the branch and all the branches underneath a setup command - double-click on the corresponding line to send the command to the setup sheet (and to the MaxiScan 3300 if you have chosen online setup) You can also use the vertical command button to send commands to the setup sheet and to the MaxiScan 3300 - click once on the button (single click). numbered sections closed branch open branch setup command

All the sections are visible in this example (Step-by-step mode has been deactivated).

MS/3300/IG/00/E/970630

5-3

Page 26

5. Setting up your MaxiScan 3300 Select the MaxiScan 3300 ♦ Choose MaxiScan 3300 with the Reader - Select command if the MaxiScan 3300 is not already selected. You can also use the Change reader icon at the top of the vertical command button to select the MaxiScan 3300. Change reader icon

5-4

MS/3300/IG/00/E/970630

Page 27

5. Setting up your MaxiScan 3300 If you want to work online with the MaxiScan 3300 1. Connect the standard RS-232 C cable between the HOST port of the MaxiScan Connexion System and the serial port of your PC if it is not already connected. 2. Choose Reader - Configure communication PC/Reader and select the Port the MaxiScan 3300 is connected to. 3. Click SelfSet. The software adapts the RS-232 communication parameters of your PC to the current settings of the MaxiScan 3300. 4. Select the Send to reader checkbox under the commands window if you want to send commands directly to the MaxiScan 3300 as well as to the setup sheet. The download arrow is displayed on the vertical command button. setup sheet vertical command button

Send to reader checkbox

MS/3300/IG/10/E/970831

5-5

Page 28

5. Setting up your MaxiScan 3300 Make a new setup for your MaxiScan 3300 1. Reset all parameters Selecting reset factory defaults makes sure that you start with a "clean" setup. Factory default settings are indicated by an asterisk (*) in the software.

1. Select reset factory defaults and double-click to send it to the setup sheet. 2. Click the next-step button to go on to the next step.

5-6

MS/3300/IG/10/E/970831

Page 29

5. Setting up your MaxiScan 3300 2. Customize your RS-232 data transmission settings

1. Look at the data transmission settings the MaxiScan 3300 needs for communication with your application host system. 2. Select the settings you need if they are not already selected by default - double-click the selected commands or click the vertical command button. 3. Click the next-step button to go on to the next step.

MS/3300/IG/10/E/970831

5-7

Page 30

5. Setting up your MaxiScan 3300 3. Customize your symbology settings Code 39 and UPC/EAN are activated by default. Do not activate symbologies that you do not need.

1. Deactivate the Code 39 and UPC/EAN default symbologies if you do not need them. 2. Activate the symbologies you need if they are not already activated by default. 3. Look at the settings for your symbologies. 4. Select the settings you need if they are not already selected by default - double-click the selected commands or click the vertical command button. If the bar codes in your application have fixed lengths, the compose 1 or 2 or 3 fixed lengths option gives the best reading efficiency and security. If not, use the compose minimum length option - select the same length as the minimum length in your application (do not select a shorter length !!). Use check digits if available to increase data security.

5. Click the next-step button to go on to the next step.