Page 11

2. Decide what’s best for your application Difficult reading situations - Tilt tilt reduces the number of effective scans for the bar code - heavy tilt prevents reading as the scan line can not cover all the bars read OK no read read OK no read

MS/3300/IG/10/E/970831

2-3

Page 12

2. Decide what’s best for your application Difficult reading situations - Pitch • pitch reduces bar width and is much more critical for high-density bar codes • reading may be possible with a pitch angle up to ± 70° • the greater the pitch angle, the more difficult it is to read

Picket fence

Ladder

2-4

MS/3300/IG/10/E/970831

Page 13

2. Decide what’s best for your application Difficult reading situations - Skew • skew reduces bar height • reading may be possible with a skew angle up to ± 40° • the greater the skew angle, the more difficult it is to read • a slight skew (scanner or labels) is good as it prevents 90° specular reflection

Picket fence

Ladder

MS/3300/IG/10/E/970831

2-5

Page 14

2. Decide what’s best for your application General remarks As a general rule, keep your application simple and consistent. Wait until you have tested your setup before you install the MaxiScan 3300 permanently.

environment

• make sure that your operating environment is suitable for your MaxiScan 3300 model - refer to the product specifications in Appendix A cables and connections

• remember to take into account the length of the operating cables and power supply cable when you set up your MaxiScan 3300 optional adjustable stand

• using the adjustable stand is more flexible than fixing the MaxiScan 3300 directly to the work surface - refer to the product specifications in Appendix A

I/O synchronization

• external input synchronization devices can be used to activate the MaxiScan 3300 - they ensure longer life for the motors and laser diode and allow you to detect unsuccessful read attempts • the MaxiScan 3300 can also send a synchronization output to control external devices according to the read result • refer to Appendix E if your application uses external synchronization devices symbologies

• use standard symbologies best suited to your application - some symbologies (Interleaved 2 of 5 for example) are less reliable than others • try to use as few symbologies as possible • fixed barcode lengths and check digits increase reading efficiency and security specular reflection

2-6

• slightly skew the scanner or labels to avoid 90° specular reflection (label exactly perpendicular to scanner) in any part of the scan

MS/3300/IG/10/E/970831

Page 15

2. Decide what’s best for your application number of scans

• a good read usually requires a minimum of 5 scans picket fence

• generally more scans per code in pass-through applications than with ladder reading ladder

• generally fewer scans per code in pass-through applications than with picket fence reading • read over whole code height - good for high-speed passthrough with variable label quality and different label positions reading distance

• high density bar codes require a shorter reading distance than low density codes - reading distance is less critical for medium-density codes depth of field

• there is more depth of field when the laser beam is horizontal with regard to the MaxiScan 3300:

more depth of field less depth of field if your application mostly needs a vertical beam, it is better to install the MaxiScan 3300 on its side:

more depth of field

MS/3300/IG/10/E/970831

2-7

Page 16

2. Decide what’s best for your application Picket fence reading skew pitch tilt picket fence

• number of scans = [ (scan width - code width ) x scan rate / pass-through speed ] - 2 Example:

scan width = 20 cm code width = 10 cm conveyor speed = 1 meter / sec (100 cm / sec)

scan rate = 450 scans / sec

[ ( 20 - 10 ) * 450 / 100 ] - 2 = 43 so there will be 43 full scans on the code

The code width value will vary slightly according to the degree of tilt and pitch. • increase the scan width (adjust the reading distance) and decrease the code width and pass-through speed to increase the number of scans Remain within the product specifications for reading distance and barcode density provided in Appendix A.

2-8

MS/3300/IG/10/E/970831

Page 17

2. Decide what’s best for your application Ladder reading skew pitch tilt ladder

• number of scans = [ (code height / pass-through speed ) x scan rate ] - 2 Example:

code height = 2.5 cm conveyor speed = 1 meter/sec (100 cm / sec) scan rate = 450 scans / sec [ (2.5 / 100) * 450 ] - 2 = 9.25 so there will be 9 full scans on t he code

The code height value will vary slightly according to the degree of tilt and skew. • increase the code height and decrease the pass-through speed to increase the number of scans • minimum code height = pass-through speed x (number of scans + 2) / scan rate if we suppose that 5 scans is a good minimum, the formula becomes:

min code height = pass-through speed x 7 / scan rate Remain within the product specifications for reading distance and barcode density provided in Appendix A.

MS/3300/IG/10/E/970831

2-9

Page 18

2. Decide what’s best for your application Scan angles

HORIZONTAL SCAN ANGLE

VERTICAL SWEEP ANGLE

VERTICAL SCAN ANGLE

HORIZONTAL SWEEP ANGLE

2-10

MS/3300/IG/10/E/970831

Page 19

3

Switch off the host system and connect up your MaxiScan 3300

Direct connection - RS-232 C, RS-422, RS-485

Switch off the host system. I/O synchronization device

ô Connect up the cables.

7-25 VDC power supply

You will have to adapt the cables to suit your application - see the Appendix.

í Plug in the mains power supply adapter. M Do not switch on the host system until you have connected up and plugged in the mains power supply adapter.

MS/3300/IG/10/E/970831

3-1

Page 20

3. Switch off the host system and connect up your MaxiScan 3300 MCS connection unit - RS-232 C, RS-422, RS-485, Current Loop The MaxiScan Connexion System unit is necessary for Current Loop applications.

Switch off the host system. I/O synchronization device

Ð HOST

SYNCHROS

ô Connect up the cables.

Ï

POWER SUPPLY 7-25 V

Ï

You may need to adapt the cables to suit your application - see the Appendix.

Ð SCANNER

í Plug in the mains power supply adapter. M Do not switch on the host system until you have connected up and plugged in the mains power supply adapter.

3-2

MS/3300/IG/10/E/970831