The text of a manual · part 6 of 26
Trakker Antares 248X Stationary Terminal User's Manual, pages 51 to 60
Pages 51 to 60 of 257
The original document is the PDF (1.9 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 2486
Page 51
nugget
39 Installing the Terminal
2
Installing the Terminal and Connecting External Devices The steps to install your T248X depend on the options you purchased and the type of network or devices to which you want to connect the terminal. To install and configure your T248X 1. If you have a wall-mount bracket, install it and install the terminal in the wall-mount bracket. See page 2-5. 2. Connect the power supply and input devices to the T248X. See page 2-8. 3. Connect the T248X to serial devices or networks. See page 2-10. 4. Connect the T248X to an existing Intermec CrossBar network. See page 2-11. 5. Connect the T2480 or T2481 directly to an Ethernet network. See page 2-14. 6. Connect sense inputs, output relays, an unattended scanner, or an amplified external speaker to the T248X terminal blocks. See page 2-15. 7. Route all the cables and secure the back panel. See page 2-25. 8. If you have a desk-mount bracket, install it and install the terminal in the desk-mount bracket. See page 2-5. 9. Turn on the terminal and configure it for your serial, multi-drop, Ethernet, or RF network. See page 2-26. These steps are described in detail in the next sections.
2-7
Page 52
TRAKKER Antares 248X Stationary Terminal User’s Manual nugget 39
Connecting Power and Input Devices You connect power and input devices through the rear enclosure of the TRAKKER Antares 248X terminal. To connect the power supply and input devices 1. Use a Phillips screwdriver to remove the six screws on the back panel.
Screw (6 places)
248XU.203
Back panel
2. Remove the back panel and place it on a clean surface. 3. Connect the power supply and input devices to the back of the terminal.
2-8
•
Connect the power supply plug to the 12V power supply connector. Next, connect the power cord from the power supply to a powered electrical outlet.
•
Connect the badge scanner 6-pin connector to the badge scanner connector.
•
Connect the Stewart 10-pin connector from the input device to the external scanner connector.
Page 53
nugget
39 Installing the Terminal
2
Connecting the Power Supply and Input Devices External scanner connector
Badge scanner connector
12V power supply connector
12V power supply plug Cable restraint 248XU.233
Cable restraint bar To power Scissors supply seal
4. Use a Phillips screwdriver to loosen one of the screws on the cable restraint. Route the power supply cable under the cable restraint. Tighten the screw to secure the cable. 5. Route all the cables under the cable restraint bar and through the scissors seal. 6. To install other devices, leave the back panel off and continue with the next instructions in this chapter. If you are not installing any other devices, continue with the instructions for “Routing Cables and Securing the Back Panel” later in this chapter.
2-9
Page 54
TRAKKER Antares 248X Stationary Terminal User’s Manual nugget 39
Connecting to Serial Devices and Networks You use the terminal’s serial ports to transfer data between the terminal and a serial device. Every T248X has one serial port (COM1) that supports RS-232 communications. You can use COM1 to connect to a serial device, such as a printer, scale, or PC. The terminal has an option for an enhanced input/output board that provides two additional serial ports. COM2 supports RS-232/422/485 communications. You can use COM2 to connect to a serial device, a wired network, or an Intermec CrossBar network. COM4 supports RS-232 communications. You need the adapter cable accessory (Part No. 067185) to use COM4. To connect the COM ports 1. Connect the 9-pin RS-232 connector from a serial device to the COM1 connector on the back of the terminal.
COM4
COM1
248XU.241
COM2
To device
2. Connect the 25-pin serial or multi-drop connector from a serial device or network to the COM2 connector on the back of the terminal. 3. Connect the 9-pin RS-232 connector from a serial device to the COM4 adapter cable on the back of the terminal. 4. Route the cables under the cable restraint bar and through the scissors seal. 5. Plug the other end of the serial or multi-drop cable into the serial device or network. 6. To install other devices, leave the back panel off and continue with the next instructions in this chapter. If you are not installing any other devices, continue with the instructions for “Routing Cables and Securing the Back Panel” later in this chapter.
2-10
Page 55
nugget
39 Installing the Terminal
2
Connecting to an Intermec CrossBar Network If you have a T248X with an enhanced input/output board, you have a second serial port (COM2) that supports RS-232/422/485 communications. With COM2, you can install the T248X in an existing CrossBar network. The T248X can communicate with a 9154 or 9161 controller using Multi-Drop protocol. One main difference between the T248X and the 9560 stationary terminal is the type of program or application you can run on the terminal. The T248X can run a C/C++ application while the 9560 terminal runs IRL programs. You need to prepare your IRL data collection program for the T248X by converting it to a Microsoft C/C++ application. There are two options for converting an IRL program: •
Use an IRL-to-C conversion program. For help, contact your local Intermec service representative.
•
Write a new C/C++ application. You can use either the TRAKKER Antares Programmer’s Software Kit (PSK) (Part No. 065332) with Microsoft Visual C/C++ version 1.5X (Part No. 590224) or EZBuilder (Part No. 066381). For help, see “Creating Applications for the Terminal” in Chapter 5.
The application needs to send and receive data through COM2. Once your application is converted, you can download the application to the T248X and begin using it in your CrossBar network. Follow the next instructions to install and configure the terminal for a CrossBar network. Host
9154/9161
T248X
Printer
T248X
9560
248XU.039
9560
Printer
2-11
Page 56
TRAKKER Antares 248X Stationary Terminal User’s Manual nugget 39 To install the T248X in an existing CrossBar network 1. Connect the 25-pin multi-drop connector from your 9154 or 9161 controller to the COM2 connector on the back of the terminal.
COM4
COM1
248XU.241
COM2
To device
2. To download applications to the T248X, you need to connect the terminal to a PC using COM1 or COM4. Connect the 9-pin RS-232 connector from the PC to the COM1 connector or the COM4 adapter cable on the back of the terminal. 3. Route the cables under the cable restraint bar and through the scissors seal. 4. Plug the other end of the multi-drop cable into the 9154 or 9161 controller. 5. To install other devices, leave the back panel off and continue with the next instructions in this chapter. If you are not installing any other devices, continue with the instructions for “Routing Cables and Securing the Back Panel” later in this chapter. Next, continue with Step 6. 6. Turn on the terminal and configure the serial ports. For help, see “Configuring the Serial Port Parameters” later in this chapter.
2-12
•
Configure COM1 or COM4 serial port parameters to match your PC serial port.
•
Configure the COM2 serial port parameters. You need to set Multi-Drop protocol, the baud rate, and the multi-drop address that you assigned for the T248X.
Page 57
nugget
39 Installing the Terminal
2
7. Use the FileCopy utility that ships with the PSK and EZBuilder to download your C/C++ application (converted from IRL) from a PC to the T248X. For help, see Chapter 5, “Using Custom Applications and Screen Mapping.” 8. Use the System Menu in the TRAKKER Antares 2400 Menu System to load and run an application. For help, see Chapter 5, “Using Custom Applications and Screen Mapping.” Once the T248X is installed, configured, and loaded with your C/C++ application, you can begin using the terminal in your CrossBar network. The T248X will run the C/C++ application and send data to the 9154 or 9161 controller. If you have existing terminals like the 9560 or 9512, these terminals will run the equivalent IRL program and send data to the controller. Note: You can use COM1 or COM4 to connect to another RS-232 serial device once you have downloaded the application.
2-13
Page 58
TRAKKER Antares 248X Stationary Terminal User’s Manual nugget 39
Connecting Directly to an Ethernet Network The TRAKKER Antares 2480 and 2481 terminals have an option for an Ethernet (10BaseT) card. With this option, your terminal can communicate to a host or any device on an Ethernet network. To connect to an Ethernet network 1. Configure your host computer and network. Assign an IP address for the T2480 or T2481. 2. Connect the Ethernet jack to the Ethernet connector on the back of the terminal.
Ethernet connector
248XU.245
To Ethernet network
3. Use a Phillips screwdriver to loosen one of the screws on the cable restraint. Route the Ethernet cable under the cable restraint. Tighten the screw to secure the cable. 4. Route the cable under the cable restraint bar and through the scissors seal. 5. Plug the other end of the Ethernet cable into an Ethernet jack on your network. 6. To install other devices, leave the back panel off and continue with the next instructions in this chapter. If you are not installing any other devices, continue with the instructions for “Routing Cables and Securing the Back Panel” later in this chapter.
2-14
Page 59
nugget
39 Installing the Terminal
2
Connecting External Devices to the Terminal Blocks If you have a T248X with an enhanced input/output board, your terminal shipped with two terminal blocks. You use the terminal blocks to connect • sense inputs (four) to monitor events, such as the opening of a door.
• output relays (four) to actuate external devices, such as a door lock.
• external speaker to amplify the terminal’s audio signals.
You need to provide the wiring and electrical equipment to connect the terminal blocks to external devices. It is much easier to connect all your wiring to the terminal blocks before attaching them to the terminal block connectors on the back of the terminal. The J12 and J13 terminal block connectors are located on the input/output board on the back of the terminal. Each relay on the terminal blocks is rated for 28V (AC or DC) maximum and 1A maximum. The next illustration and table shows the assignments for each block.
J13
J12
1 2 3 4 5 6 7 8 9 101112 1 2 3 4 5 6 7 8 9 101112
J12 Position
Type
Description
1 2 3
Output relay 1 Output relay 1 Output relay 1
Normally open contact Common Normally closed contact
4 5 6
Output relay 2 Output relay 2 Output relay 2
Normally open contact Common Normally closed contact
7 8 9
Output relay 3 Output relay 3 Output relay 3
Normally open contact Common Normally closed contact
2-15
Page 60
TRAKKER Antares 248X Stationary Terminal User’s Manual nugget 39
Terminal Block Definitions (continued) J12 Position
Type
Description
10 11 12
Output relay 4 Output relay 4 Output relay 4
Normally open contact Common Normally closed contact
J13 Position
Type
Description
1 2
Sense input 1 Sense input 1
Optically isolated input A Optically isolated input B
3 4
Sense input 2 Sense input 2
Optically isolated input A Optically isolated input B
5 6
Sense input 3 Sense input 3
Optically isolated input A Optically isolated input B
7 8
Sense input 4 Sense input 4
Optically isolated input A Optically isolated input B
9 10
Reserved Reserved
Reserved Reserved
11 12
External speaker External speaker
Speaker output Speaker ground
The next sections explain how to connect and use the terminal blocks.
Activating External Devices With the Output Relays The T248X has four output relays to actuate external devices, such as a door lock or a turnstile lock. You need to supply the wiring and electrical equipment. Each relay contact is rated for 28V (AC or DC) maximum and 1A maximum. You control the relays with an application that uses the IM_GET_RELAY and the IM_SET_RELAY functions in the TRAKKER Antares Programmer’s Software Kit. If you remove power to the T248X, the relays turn off. The relays remain off until the T248X receives a command from the application. For help, see the TRAKKER Antares Programmer’s Software Kit Reference Manual. The output relays are grouped in sets of three. There are three positions for each output relay on the J12 terminal block. You connect the external device to the appropriate positions depending on the type of default contact state you want to set for the device as explained next.
2-16