Page 61

nugget

39 Installing the Terminal

2

To connect an output relay 1. Use a straight-slot screwdriver to loosen the screws on a set of three output relay positions on the J12 terminal block. For example, if you are connecting a single external device, you would loosen the screws for positions 1 and 2 or positions 1 and 3 on the J12 terminal block.

248XU.043

Note: If the terminal blocks are connected to the I/O board, you may need to remove them to connect the wires. For help, see “Removing the Terminal Blocks From the Input/Output Board” later in this section. 2. Insert the wires for the external device into the appropriate positions. a. If the device requires a normally open contact, connect the wires to positions 1 and 2, 4 and 5, 7 and 8, or 10 and 11 on the J12 terminal block. b. If the device requires a normally closed contact, connect the wires to positions 2 and 3, 5 and 6, 8 and 9, or 11 and 12 on the J12 terminal block. 3. Use a straight-slot screwdriver to tighten the screws and connect the wires.

2-17

Page 62

TRAKKER Antares 248X Stationary Terminal User’s Manual nugget 39

Sample Output Relay Application

Relay output

J12 terminal block 1

2 3 4 5 6

T248X 7 8 9 10 11 12 External device

Electric door opener Secondary circuit 248XU.044

4. Position the terminal block above the J12 terminal block connector on the I/O board. Gently push the terminal block on to the connector until it snaps in place. Note: Do not attach the J13 terminal block if you still need to connect the sense inputs or an external speaker.

248XU.158

2-18

Page 63

nugget

39 Installing the Terminal

2

5. Route the wires through the snap-in plastic loop that is just to the right of the power supply connector. 6. Use a Phillips screwdriver to loosen one of the screws on the cable restraint. Route the wires under the cable restraint. Tighten the screw to secure the wires. 7. Route the wires under the cable restraint bar and through the scissors seal. 8. If you need to connect sense inputs or an external speaker, continue with the next instructions in this section. If you are not installing any other devices, continue with the instructions for “Routing Cables and Securing the Back Panel” later in this chapter.

Monitoring Events With the Sense Inputs The T248X has four sense inputs to monitor events, such as the opening of a door or the input from an unattended bar code scanner. You need to supply the wiring and electrical equipment. Each sense input monitors its line for an input signal at 5 to 28V (AC or DC) maximum. The terminal’s current limiter circuitry limits the current to a nominal value of 900µA. You monitor the sense inputs with an application that uses these two functions from the TRAKKER Antares Programmer’s Software Kit: •

IM_GET_SENSOR_ALL

•

IM_GET_SENSOR_INPUT

When a sense input detects a signal, the circuitry goes into a “set” state. The circuitry remains set until the terminal application reads the status of the sense inputs. When the T248X executes one of the functions listed earlier, it records the current status and resets the circuitry. For help, see the TRAKKER Antares Programmer’s Software Kit Reference Manual. The next illustration shows a typical connection to a sense input. In this example, a normally open door sense switch is wired in series with the sense input and a secondary power circuit. When the door switch is closed, the sense input detects the 5 to 28V output from the power circuit. The sense input relays are grouped in pairs. There are two positions for each of the four sense inputs on the J13 terminal block. You connect the external device to the appropriate positions to monitor the device as explained next. Note: Each sense input is optically isolated to protect the T248X from any damaging currents that may inadvertently enter though the input line.

2-19

Page 64

TRAKKER Antares 248X Stationary Terminal User’s Manual nugget 39

Sample Sense Input Application

Optically isolated input

Current limiter

J13 terminal block 1 2

T248X

3

4 5 6

7 8 9 10 11 12

External device

Normally open door sense switch

Secondary circuit 248XU.094

To connect a sense input relay 1. Use a straight-slot screwdriver to loosen the screws on a pair of sense input relay positions on the J13 terminal block.

248XU.043

2-20

Page 65

nugget

39 Installing the Terminal

2

For example, if you are monitoring a bar code scanner on a conveyor line, you would loosen the screws for positions 1 and 2 on the J13 terminal block. Note: If the terminal blocks are connected to the I/O board, you may need to remove them to connect the wires. For help, see “Removing the Terminal Blocks From the Input/Output Board” later in this section. 2. Insert the wires from the external device into the appropriate positions. The switch mechanism on each device should normally be open. 3. Use a straight-slot screwdriver to tighten the screws and connect the wires. 4. Position the terminal block above the J13 terminal block connector on the I/O board. Gently push the terminal block on to the connector until it snaps in place.

248XU.158

5. Route the wires through the snap-in plastic loop that is just to the right of the power supply connector. 6. Use a Phillips screwdriver to loosen one of the screws on the cable restraint. Route the wires under the cable restraint. Tighten the screw to secure the wires. 7. Route the wires under the cable restraint bar and through the scissors seal. 8. If you need to connect an external speaker, continue with the next instructions in this section. If you are not installing any other devices, continue with the instructions for “Routing Cables and Securing the Back Panel” later in this chapter.

2-21

Page 66

TRAKKER Antares 248X Stationary Terminal User’s Manual nugget 39

Attaching an External Speaker The T248X terminal has a single internal speaker to sound both audio signals and beep sequences as you use the terminal. You can attach an amplified external speaker to hear the terminal’s audio signals in a high noise work environment. The internal speaker continues to operate when an external speaker is connected. You need to supply the wiring and the amplified external speaker. The terminal can drive an external speaker down to 100 ohms. To attach an external speaker 1. Use a straight-slot screwdriver to loosen the screw on position 11 on the J13 terminal block.

248XU.154

Note: You can connect your external speaker with or without the J13 terminal block attached to the I/O board. 2. Insert the wire from your speaker into position 11 and then tighten the screw to connect the wire. 3. Use a straight-slot screwdriver to loosen the screw on position 12 on the J13 terminal block. 4. Insert the ground wire for the speaker into position 12 and then tighten the screw to connect the wire. 5. If the J13 terminal block is not attached to the I/O board, position the terminal block above the J13 terminal block connector on the I/O board. Gently push the terminal block on to the connector until it snaps in place.

2-22

Page 67

nugget

39 Installing the Terminal

2

Attaching the Terminal Blocks

248XU.158

6. Route the wires through the snap-in plastic loop that is just to the right of the power supply connector. 7. Use a Phillips screwdriver to loosen one of the screws on the cable restraint. Route the speaker wires under the cable restraint. Tighten the screw to secure the cable. 8. Route the cable under the cable restraint bar and through the scissors seal. 9. If you are not installing any other devices, continue with the instructions for “Routing Cables and Securing the Back Panel” later in this chapter.

2-23

Page 68

TRAKKER Antares 248X Stationary Terminal User’s Manual nugget 39

Removing the Terminal Blocks From the Input/Output Board You may need to remove the terminal blocks to make wiring changes. It is easier to connect all your wiring to the terminal blocks before attaching them to the terminal block connectors on the back of the terminal. You need a pair of needle-nose pliers that have a threaded grip to remove a terminal block. To remove the terminal blocks 1. Starting at one end, use the pliers to grip one section of a terminal block and gently wiggle the pliers up and down to loosen the block.

248XU.040

2. Move the pliers to the next section of the terminal block and gently wiggle the pliers up and down to loosen the block. Repeat the procedure until you have loosened all sections of the terminal blocks. 3. Use your hand to pull the terminal block off the connector. 4. If some of the sections of a terminal block have come apart, slide the sections back together to make one block with four sections. 5. Use the instructions earlier in this section to connect an external device and attach the terminal blocks to the input/output board.

2-24

Page 69

nugget

39 Installing the Terminal

2

Routing Cables and Securing the Back Panel Once you have connected power, input devices, Ethernet, and external devices, you can secure all the cables and attach the back panel. To route all cables and secure the back panel 1. Make sure the sense input wires, output relay wires, and external speaker wires are routed through the snap-in plastic loop that is just to the right of the power supply connector. 2. Make sure the power supply cable, Ethernet cable, sense input wires, output relay wires, and external speaker wires are secured in the cable restraint. To secure cables and wires in the cable restraint, use a Phillips screwdriver to loosen the screws on the cable restraint. Route the cables and wires under the cable restraint. Tighten the screw to secure the cable. 3. Route all cables under the cable restraint bar and through the scissors seal.

Plastic loop

Cable restraint Cable restraint bar

Scissors seal 248XU.071

4. With the seal facing toward the terminal, place the back panel on the back of the terminal. 5. Use a Phillips screwdriver to tighten the six screws to 19 in-lb torque. 6. If you are using the desk-mount bracket, install the desk-mount bracket and install the terminal in the bracket. If you are using the wall-mount bracket, close and secure the bracket. 7. Turn on the terminal and configure the network parameters. Continue with the instructions in the next section.

2-25

Page 70

TRAKKER Antares 248X Stationary Terminal User’s Manual nugget 39

Turning On the Terminal for the First Time Once the power supply is connected and you have installed the terminal, you are ready to turn on the terminal. To turn on the terminal f

1. Press the key on the keypad. The terminal runs POST (power-on self test) and then the Boot Menu appears.

BOOT

MENU

1

-

Boot

2

-

Run

3

-

Power

POWER

DOWN

System Loader Down

IN

60

SEC 248XU.104

]

Note: If the backup battery charge is low and the terminal fails POST, a POST results screen appears. If the backup battery is the only failed test, press to exit the screen. If any other test failed, contact your local service representative before using the terminal.

to boot the terminal and initialize the firmware. The TRAKKER 2. Press Antares screen appears.

VERSION 3.XX COPYRIGHT 1996-1998

248XU.127

2-26