Page 41

nugget

39 Introducing the TRAKKER Antares 248X Terminal

1

Charging the Backup Battery The backup battery backs up all memory and the real-time clock in case of a power failure. The backup battery is shipped inside the terminal, but may not be fully charged when you initially unpack your terminal. You need to fully charge the backup battery after you first install it. The terminal continuously monitors the backup battery voltage level and charges the backup battery whenever the voltage level gets low. If an external power supply is not connected or powered, the backup battery will not charge. If the Power status light blinks, the backup battery charge is low. You can operate the terminal while the backup battery is charging. There are two ways to find out if the backup battery charge is low: •

The Power status light is blinking on the left side of the screen.

•

Check the status of the backup battery using the Backup Battery/PIC Status diagnostic.

Note: The backup battery charger operates between 32°F and 104°F (0°C and 40°C). If you are continuously using the terminal in an environment that is outside this temperature range, the backup battery will not charge. You may need to protect the terminal and create an environment that is within the charging temperature range for a few hours every week to keep the backup battery charged. To charge the backup battery 1. Make sure the power supply is connected to the terminal and a powered electrical outlet. 2. Let the power supply charge the backup battery for 24 hours to fully charge the backup battery.

Recognizing a Low or Discharged Backup Battery If you see the Power status light blinking, the terminal is indicating that the backup battery power is low. Make sure the external power supply is connected to the terminal and a powered electrical outlet. The backup battery is fully charged within 24 hours. If the Power status light continues to blink after 24 hours and the power supply is attached, the backup battery may be bad. Use the Battery/PIC Status diagnostic in the TRAKKER Antares 2400 Menu System to check the status of the backup battery. The Battery/PIC Monitor diagnostic screen displays the current status (good or bad), the voltage, the temperature, and the charging status of the backup battery.

1-23

Page 42

TRAKKER Antares 248X Stationary Terminal User’s Manual nugget 39 If the backup battery status is bad or the backup battery will no longer hold a charge (Power status light is always blinking), you may need to replace the backup battery. You need to backup all your data stored in RAM. Any data stored in flash memory or on the SRAM drive will be saved. For help, contact your local Intermec Service Representative. Note: The NiCd backup battery is NOT user-serviceable. You must return the TRAKKER Antares 248X terminal to Intermec to replace the backup battery. Caution When you replace the backup battery, all data stored in RAM is lost. Conseil Lors du remplacement de la batterie de secours, toutes les données stockées dans la mémoire vive (RAM) sont perdues. Note: If you use the terminal in a very cold or very hot temperature environment, battery life will be reduced or the backup battery may not charge. For more information, see “Backup Battery” earlier in this chapter.

Defining the Terminal’s Memory and Drives The TRAKKER Antares 248X terminals come with the following memory and drives:

750K flash drive

Drive C Optional 2MB flash memory 256K configurable RAM drive

Drive D

Optional 2MB or 4MB extended storage drive

Drive E

Drive G 248XU.180

1-24

Page 43

nugget

39 Introducing the TRAKKER Antares 248X Terminal

1

Drive C is a 750K flash drive on the T248X. You can store up to 32 files on drive C. Applications must be stored on drive C. Drive D is an optional 2MB extended flash memory storage that can be used as a storage drive or a storage space for double-byte fonts. You can store up to 32 files on drive D or store a 2MB double-byte font set. If you configure the flash memory as drive D, use this drive to store large lookup tables and data files. For help configuring the drive, see “Configuring Drives and Memory on the Terminal” in Chapter 3. Note: You can only configure the 2MB flash memory as a drive or to store fonts. You cannot use the space for both. If you configure drive D, you cannot store a font in flash memory. Drive E is a configurable RAM drive (up to 256K). By default, the RAM drive is not configured and the memory is available for programmable (Malloc) memory allocations. You can store up to 32 files on drive E. The contents of the RAM drive are erased when you boot or reset the terminal, or change the backup battery. For help configuring the drive, see “Configuring Drives and Memory on the Terminal” in Chapter 3. Drive G is an optional 2MB or 4MB extended storage drive that is available for a T2480/1 terminal with Ethernet connectivity or a T2485/6 terminal. You can store up to 32 files on drive G. Use this drive to store large lookup tables and data files. Note: On each drive, filenames are customer defined using eight characters with a three-character extension. On the TRAKKER Antares terminals, applications are customer defined. You have 512K total RAM for the application execution space. You can configure up to 256K of the total 512K application execution space as a RAM drive. If the RAM drive is configured, your application execution space is reduced by the amount of the RAM drive. Application execution space

+

Drive E

≤

512K RAM

Note: The remaining RAM is automatically used as the Malloc/free dynamic memory pool. For example, if the application size is 64K and drive E is configured as a 256K RAM drive, you are using 320K of the 512K application execution space. The application uses the remaining 192K of RAM as a Malloc/free dynamic memory pool. The application size is not necessarily the size of the *.BIN file. You can use the compiler map file output to determine the application size.

1-25

Page 44

TRAKKER Antares 248X Stationary Terminal User’s Manual nugget 39

Where Do You Go From Here? Now that you understand the features and capabilities of your new TRAKKER Antares terminal, you can use this manual to learn how to perform these tasks:

1-26

Task or Feature

See This Chapter

To learn how to install the terminal and connect it to your network

Chapter 2, “Installing the Terminal”

To learn how to change the terminal’s configuration

Chapter 3, “Configuring the Terminal”

To learn how to use the terminal in your 2.4 GHz RF or wired data collection system and learn about network protocols

Chapter 4, “Operating the Terminal in a Network”

To learn how to download and run custom applications or screen mapping on your programmable terminal

Chapter 5, “Using Custom Applications and Screen Mapping”

Page 45

2 Installing the Terminal

Page 46

This page is a scan with no text; see it in the PDF.

Page 47

nugget

39 Installing the Terminal

2

This chapter explains how to install the TRAKKER Antares 248X terminal in your serial, Ethernet, or RF network. You will also learn how to turn on the terminal and configure the network parameters to start using the terminal.

Preparing to Install the Terminal Make sure you have the necessary equipment to install and connect the T248X to your network. The terminal ships with this equipment: •

T2480, T2481, T2485, or T2486 terminal

•

Antenna (ships only with the T2485 and T2486)

•

Terminal blocks (ships only with the enhanced input/output board option)

•

Power supply

•

North American power cord

Note: A badge scanner may already be installed on the terminal if you ordered this option. In addition, you may need this equipment (not shipped with the T248X) to install the terminal: •

Power cord for terminals used outside of North America

•

Mounting bracket (desk-mount or wall-mount)

•

Input device (badge scanner, wand, laser scanner, CCD scanner)

•

RS-232 or RS-232/422/485 serial communications cables

•

Multi-drop cable

•

Ethernet (10BaseT) cable

•

Wiring for sense inputs, output relays, and external speakers

Before you install the terminal, you should: 1. Choose a location to mount the terminal. 2. Attach the antenna to the T2485 or T2486. 3. Find out about using the desk-mount and wall-mount brackets. Each of these topics are covered in the next sections. You should also make sure you are familiar with the connectors and equipment inside the terminal’s rear enclosure. For help, see “Understanding the Back Panel” in Chapter 1.

2-3

Page 48

TRAKKER Antares 248X Stationary Terminal User’s Manual nugget 39

Choosing a Location You can mount the T248X on a horizontal surface, such as a desktop or table-top, or on a vertical surface, such as a wall. The easiest way to mount the T248X is to use one of Intermec’s mounting brackets: •

TRAKKER Antares 248X Desk-Mount Bracket (Part No. 066709)

•

TRAKKER Antares 248X Wall-Mount Bracket (Part No. 066708)

For more information on the brackets, see “Using the Desk-Mount or Wall-Mount Bracket” later in this chapter. Choose a mounting location for the T248X that provides • easy access to the badge scanner or other input devices.

• easy access to the keypad.

• an unobstructed view of the screen.

• clearance for the cables.

• access to a powered AC electrical outlet.

• good communications for the antenna where the antenna is not too close to a metal wall.

To plan for and prepare a mounting location, use the actual size (1:1 scale) mounting templates provided in Appendix D, “Keypad Labels and Terminal Mounting Templates.”

Attaching the Antenna On the T2485 and T2486, the antenna is shipped separately. Remove the antenna from the shipping box and attach the antenna as shown. Choose a location for the terminal where the antenna can be effective. Do not place the terminal where the antenna is too close to a metal wall or it will limit the communications range. You can also use an Intermec-approved accessory antenna to improve RF communications. Note: See your Intermec sales representative for information about and a list of Intermec-approved accessory antennas for the T248X.

2-4

Page 49

nugget

39 Installing the Terminal

2

Caution Make sure all components with antennas are at least 1 foot (0.3 meters) apart when power is applied. Failure to comply could result in equipment damage. Conseil Assurez-vous que la distance entre tous les éléments avec antennes soit d’au moins un pied (0.3 mètres) avant de faire la connexion avec l’alimentation électrique, faute de quoi vous risquez d’endommager votre installation.

Using the Desk-Mount or Wall-Mount Bracket There are two accessories to help you mount the terminal: •

TRAKKER Antares 248X Desk-Mount Bracket (Part No. 066709)

•

TRAKKER Antares 248X Wall-Mount Bracket (Part No. 066708)

To plan for and prepare a mounting location, use the actual size (1:1 scale) mounting templates provided in Appendix D, “Keypad Labels and Terminal Mounting Templates.” To install the desk-mount bracket 1. Connect power and all other devices through the back panel of the terminal. 2. Install the desk-mount bracket and the terminal. For help, see the accessory instruction sheet.

248XU.033

Desk-mount bracket

2-5

Page 50

TRAKKER Antares 248X Stationary Terminal User’s Manual nugget 39 To install the wall-mount bracket 1. Install the wall-mount bracket and the terminal. For help, see the accessory instruction sheet. 2. Connect power and all other devices through the back panel of the terminal. To mount the power supply •

The T248X and the power supply are dust and moisture protected to IEC 60529/IP53 only when installed properly in the Intermec deskmount or wall-mount bracket. The brackets use a power supply holder to effectively protect the power supply from dust and moisture. For help, see the accessory instruction sheets.

248XU.034

Wall-mount bracket

Intermec recommends that you use the desk or wall-mount bracket to mount the T248X and protect the power supply. You can use other mounting brackets or enclosures. However, without the Intermec desk or wall-mount bracket, the power supply is intended for indoor use only. Use of any other mounting brackets or enclosures will void the environmental protection ratings of the terminal. Warning Installation of the power supply must be performed strictly in accordance with the procedures contained in the TRAKKER Antares 248X desk and wall-mount bracket instruction sheets. Failure to protect the power supply in areas of high dust and moisture may result in injury or death due to electric shock. Avertissement L’installation de la source d’alimentation doit être exécutée en respectant de façon stricte les procédures décrites dans les feuilles d’instruction du TRAKKER Antares 248X de bureau et monté au mur. L’échec de la protection de la source d’alimentation dans des zones de grande poussière et d’humidité peut entraîner des blessures ou la mort en raison d’un choc électrique.