Page 31
nugget
1
39 Introducing the TRAKKER Antares 248X Terminal
To flush the , , , or key from the buffer without performing any action, just press the key again. The status light is turned off. To use the FnL, FnR, Ctrl, and Shift keys
. The Modifier Key status light is turned on. For
1. Press , , , or example, press .
2. Press the second key. For example, press to type the uppercase letter A. The Modifier Key status light is turned off.
Capitalizing All Characters To type all alphabetic characters as uppercase letters, you can press every letter you type, or you can enable the Caps Lock feature.
before
Note: There is no Caps Lock feature on the oversized function numeric keypad. To enable Caps Lock 1. Press
. The Modifier Key status light turns on.
. The Caps Lock status light turns on. Note: On a German alphanumeric keypad, press 8.
2. Press
3. Type an alphabetic character. The letter appears as an uppercase character on the terminal’s screen. For example, press to type an uppercase letter F. Caps Lock remains enabled until you disable it.
%
Caps Lock status light
248XU.079
1-13
Page 32
TRAKKER Antares 248X Stationary Terminal User’s Manual nugget 39 To type a lowercase letter with Caps Lock enabled •
Press and an alphabetic character. For example, press lowercase letter f.
% to type a
To disable Caps Lock 1. Press
. The Modifier Key status light turns on.
. The Caps Lock status light turns off. Note: On a German alphanumeric keypad, press 8.
2. Press
3. Type an alphabetic character. The letter appears as a lowercase letter on the terminal’s screen. Note: You can also use the Keypad Caps Lock configuration command to enable or disable Caps Lock on the terminal.
Adjusting the Contrast and Beep Volume From the Keypad There are two special features built into the terminal’s keypad. You can use a key or key sequence to: •
Adjust the display contrast.
•
Change the volume of the terminal’s audio signals.
Note: When you use the keypad to change the display contrast or beep volume, the changes are not saved permanently in flash memory. You can save the changes in flash memory later. For help, see Chapter 3, “Configuring the Terminal.” To change the display contrast • h h
Look for the key or symbol on your keypad. Press the key or the key sequence to change the display contrast. Each time you press the keys to change the display contrast, it changes the contrast by one level. Type of Keypad
Press the Key(s)
6
English, Italian, Portuguese, Spanish, IBM 3270, IBM 5250, and VT/ANSI German French Oversized Function Numeric
1-14 h
$ 9
Page 33
nugget
39 Introducing the TRAKKER Antares 248X Terminal
1
Adjusting the Contrast From the Keypad \
?
esc
Q tab
E
W
S
A
R
T
F
D
.
,
/
U
Y
G
H
-
+ I
J
O
K
P
L Ctrl
Caps
I/O
:
"
Z
X
C
V
B
N
M Fn L
_f
242XU.049
There are eight contrast levels that define the contrast (light or dark) of the characters against the background terminal screen. If the contrast is at the highest level (7), the characters are bright against a bright background. If you press the key or the contrast key sequence, the contrast changes to the lowest contrast level (0) and the characters are dark against a dark background.
h
To change the volume of the audio signals •
Look for the symbol on your keypad. Press the key sequence to change the volume of the terminal’s audio signals. Each time you press the key sequence, it makes the beep and keyclick volume one level louder. Type of Keypad English, IBM 3270, IBM 5250, and VT/ANSI French, German, Italian, Portuguese, and Spanish Oversized Function Numeric
Press the Key(s)
$ 0 h
There are five volume levels including off. If the volume is at the loudest level and you press the key sequence, the beep and keyclick volume are turned off. If you press the key sequence again, the beep and keyclick volume changes to the quietest level.
1-15
Page 34
TRAKKER Antares 248X Stationary Terminal User’s Manual nugget 39
Adjusting the Beep Volume From the Keypad \
?
esc
Q
E
W tab
R
S
A
T
U
Y
F
D
.
,
/
G
H
-
+ I
J
O
P
K
L
: Ctrl
Caps
I/O
Z
"
C
X
V
B
N
M Fn L
_f
242XU.047
Using the Function Key Labels Your terminal ships with strips of function key labels. You can use the labels to identify custom function keys. Write the name for each function key on a strip of five labels. Insert the strip into the slot above the function keys. You can create your own pre-printed function key labels. For the exact function key label measurements, see Appendix D, “Keypad Labels and Terminal Mounting Templates.” Note: There are two sizes of function key labels. Use the labels that are slightly larger if you have a T248X with an oversized function numeric keypad. Use the smaller labels for an alphanumeric keypad.
\
?
esc
Q tab
E
W
S
A
R
F
D
.
,
/
T
U
Y
G
H
J
F6
P
L bksp
: Ctrl
Z
"
F7
F1
O
K
Caps
I/O
-
+ I
X
F8
F2
C
V
F4
N
M Fn L
Fn R
_f
_f _ Enter
F10
F9
F3
B
F5
&
*
7
8
$
%
9
4
5
6
!
@
#
1
2
3
<
Ins
Del
0
>
.
248XU.247
1-16
Page 35
nugget
39 Introducing the TRAKKER Antares 248X Terminal
1
How to Use the Terminal’s Screen You can use the TRAKKER Antares terminal’s screen to view data, run applications, monitor the terminal’s status, and for many other functions. The terminal’s black and white screen is CGA compatible. You can use these features of the screen: •
Use the status lights to monitor the status of backup battery power, RF and network communications, special keys, and bar code scanning.
•
Choose a different font size, adjust the row spacing, or change the video mode.
•
In an application, use the terminal’s screen as a viewport to see a full-size terminal screen of 25 lines by 80 characters.
Each screen feature is explained in the next sections. Note: If you are using the terminal in a cold environment, the LCD may respond and display information more slowly than in a warm environment.
Using the Status Lights You can use the terminal’s status lights to monitor the status of backup battery power, RF and network communications, special keys, and bar code scanning. The status lights only flash or turn on to indicate the current status. The Power status light is amber and all other lights are green. When you have the terminal turned off (Suspend mode), the status lights are also off.
Power Network Connect Network Transmit Modifier Key Caps Lock Good Read User Defined 248XU.219
1-17
Page 36
TRAKKER Antares 248X Stationary Terminal User’s Manual nugget 39
Using the Status Lights Power This status light remains off when you have power to the terminal, a charged backup battery, and the terminal is on. The light blinks when the backup battery has a low power charge or if you try to turn on the terminal with no external power supply connected to the terminal. The Power status light turns off once the backup battery charges. For help, see “Learning About the Power Supply and Backup Battery” later in this chapter. Network Connect This status light tells you if the T2480 or T2481 is connected to your Ethernet network or tells you if the T2485 and T2486 is connected via RF communications to your 2.4 GHz RF network. The Network Connect status light may be turned off, blinking, or turned on. T2480/1: Ethernet & TCP/IP Ethernet & UDP Plus T2485/6: TCP/IP UDP Plus
Status Light Off
Status Light Blinks
Status Light On
Not connected to the Ethernet network.
Not used.
Connected to the Ethernet network.
Not connected to the Ethernet network.
Not connected to the Model 200 Controller.
Connected to the controller.
Not connected to an access point.
Not used.
Connected to an access point.
Not connected to an access point.
Not connected to the Model 200 Controller.
Connected to an access point and the controller.
When the Network Connect status light is turned off, you are either not connected to the network or the terminal is not configured. Make sure the Network Activate command is enabled and that the terminal is configured correctly for your network. If your T2485/6 is configured correctly, you may be out of range of an access point. In a UDP Plus network, the Network Connect status light is not instantaneously updated but does tell you the communications status the last time data was sent or received from the terminal. For help with network communications, see Chapter 4, “Operating the Terminal in a Network.” Network Transmit This status light turns on when data is buffered in the RF or Ethernet network interface. The data is either waiting to be transmitted to the Model 200 Controller or host, or received data has not been accepted by the application on the T248X. When no data is being buffered in the interface, the Network Transmit status light is off.
1-18
Page 37
nugget
39 Introducing the TRAKKER Antares 248X Terminal
1
Using the Status Lights (continued) Modifier Key This status light turns on when you press one of the four modifier keys: , , , or . The modifier key is stored in the keypad buffer until you press another key. When you press a second key, the key combination is entered into the terminal and the status light turns off.
to enable the Caps Caps Lock This status light turns on when you press Lock feature and type all alphabetic characters as uppercase letters. When you press to disable Caps Lock, the light turns off.
Note: On a German alphanumeric keypad, press
8.
Good Read This status light turns on when you successfully scan a bar code label with an input device (badge scanner, laser scanner) that is connected to the terminal. The status light turns off after 2 seconds. User Defined This status light is user defined. You can program this status light to turn on and off for any task or error within your application.
Customizing the Font Size and Screen Parameters On each T248X, you can customize the font size, row spacing, and video mode to meet your needs. You can configure these options: Font size Set the font size to 8x8 (8 pixels by 8 pixels), 8x16, or 16x16. The default for the T248X terminals is the 8x16 font size (single-width and doubleheight characters). Note: The 8x8 font size is not available on the T2480 and T2485. Row spacing Set the row spacing to a value from 0 to 8 on the T2481 and T2486 terminals. Row spacing lets you define the amount of additional space (scan lines) between the lines. The number of scan lines is two times the value you set for the row spacing. A scan line is a row of pixels. A value of 8 adds 16 blank scan lines to increase the space between lines. For the T2481 and T2486, the default is 0. Note: The Row Spacing command is not available on the T2480 and T2485. Video mode Set the Video mode to original, normal, or reverse. The default is original and displays black characters on a white background. Original is the Video mode set at the Intermec factory. Normal mode displays black characters on a white background. Reverse mode displays white characters on a black background.
1-19
Page 38
TRAKKER Antares 248X Stationary Terminal User’s Manual nugget 39 Depending on the T248X model you have, there are two default screen sizes: •
4 lines by 40 characters for the T2480 and T2485
•
12 lines by 40 characters for the T2481 and T2486
Use this next table to determine the font size that meets your needs. Model
Font Size
Row Spacing
Characters Displayed
T2480 and T2485
8x16 (default)
7 (default)
40 characters by 4 lines
16x16
7 (default)
20 characters by 4 lines
8x8
0 8
40 characters by 25 lines 40 characters by 9 lines
8x16 (default)
0 (default) 8
40 characters by 12 lines 40 characters by 6 lines
16x16
0 8
20 characters, 12 lines 20 characters by 6 lines
T2481 and T2486
Note: The row spacing cannot be changed on the T2480 and T2485.
Using the Screen As a Viewport The TRAKKER Antares 248X terminal screen shows 4 lines by 40 characters up to a maximum of 25 lines by 80 characters of data at one time (depending on the model and configuration). In terminal emulation (TE) or custom applications, the terminal’s screen may show only part of each 25 line by 80 character screen that appears on a full-size terminal. If your application supports viewporting, you can use the terminal screen as a viewport to move around and see the entire 25 x 80 screen. The viewport lets you view screens and enter data by showing the part of the screen you are using. When you are using one of the Intermec TE applications, the viewport automatically moves to the cursor when there is data entry from the host computer or the terminal. You can configure the viewport for your TE applications to • follow the cursor.
• center the viewport around the cursor.
For help on configuring the TE viewport options, see the TRAKKER Antares Terminal Emulation User’s Guide.
1-20
Page 39
nugget
39 Introducing the TRAKKER Antares 248X Terminal
1
Understanding the Terminal’s Audio Signals The TRAKKER Antares 248X terminal has an internal speaker to sound audio signals and beep sequences as you use the terminal. For example, you hear a low beep tone each time you enter or scan a valid command. You can change the audio volume to meet the needs of your working environment. For example, use a quiet beep in a library or a loud beep in a manufacturing plant. There are three ways to change the audio volume:
$ h
0
•
Use the keypad (press , , or depending on your keypad). For help, see “Adjusting the Contrast and Beep Volume From the Keypad” earlier in this chapter.
•
Use the Beep Volume command.
•
Use the TRAKKER Antares 2400 Menu System. For help, see Chapter 3, “Configuring the Terminal.”
Note: If the Beep Volume is turned off, you will not hear any audio signals including the keyclick. If you have a T248X with an enhanced input/output board, you can attach an amplified external speaker to amplify the terminal’s audio signals. For help, see Chapter 2, “Installing the Terminal.” The next table explains the purpose of each beep sequence you may hear. Beep Sequence
Description
Low beep
You entered a valid command or the data you entered was stored.
High beep
You entered valid data, the terminal decoded a label, or the terminal decoded the last row of a two-dimensional symbology.
Three low beeps
You entered or scanned an invalid command or data.
Four low beeps
When you boot the terminal, you hear four low beeps once the power-on self test (POST) has executed successfully.
Low beep, high beep, low beep, high beep
You hear this beep sequence when POST failed and did not execute successfully.
Click
When you press a key, the terminal sounds a click. You can disable the keyclick. The terminal also clicks while you are scanning a two-dimensional symbology (Code 16K or Code 49) bar code label.
Low beep (every 15 seconds)
The main battery pack is low. You need to replace or recharge the battery pack. For help, see the next section, “Learning About the Power Supply and Backup Battery.”
1-21
Page 40
TRAKKER Antares 248X Stationary Terminal User’s Manual nugget 39
Learning About the Power Supply and Backup Battery The TRAKKER Antares 248X terminal operates using an external power supply. It has a rechargeable NiCd (Nickel-Cadmium) backup battery that is designed to back up all memory and the real-time clock while AC power is not supplied. You must have a power supply connected to operate the terminal. An Intermec power supply and North American power cord ship with the terminal. If you are using the terminal outside North America, you need to purchase the appropriate power cord for your local power supply.
Backup Battery The backup battery is a rechargeable NiCd battery that is designed to back up all memory and the real-time clock while AC power is not supplied. The backup battery provides protection for power surges, sags, spikes, and dropouts. Here are the features of the backup battery: •
During a power loss, the terminal uses backup battery power to continue operating for 3 seconds. If power is still not restored, the terminal saves all data and turns off. However, if the backup battery charge is low, the terminal cannot protect the data against a power loss and will turn off immediately.
•
The backup battery is rechargeable. The power supply provides the power to charge the backup battery when required with the terminal turned on or off. The terminal continuously monitors the backup battery voltage level and charges the backup battery whenever the voltage level gets low.
•
The backup battery will last for a minimum of three years before its capacity is reduced. Battery life depends on the age of the backup battery, your usage, and RF duty cycle factors. If you are using the terminal in extreme environments (very hot or very cold), battery life will be reduced and you may need to replace the backup battery more often.
•
The backup battery will provide backup battery power for a minimum of 2 weeks with a fully-charged backup battery pack installed and no AC power. If you plan to store the terminal for a long period of time, save any data stored in RAM to another drive on the terminal. If the backup battery is still providing power when you reconnect the power supply and turn the terminal on, the terminal resumes exactly where it was when you turned it off, or restarts your application. Note: If the Resume Execution command is allowed, the terminal will resume the application when you turn on the terminal. Otherwise, the terminal boots and the application restarts.
1-22