Page 256

Nugget

Troubleshooting Co de 39

6

Problems While Configuring the Terminal (continued) Problem

Solution

You are configuring the serial port and see this error message when exiting the Configuration Menu:

You cannot set EOM or SOM to any of these values: AFF (ACK), DLE, NEG (NAK), Poll, RES (EOT), REQ (ENQ), SEL, XOFF, or XON. You need to change the value of EOM or SOM. Choose Serial Port from the Communications Menu.

Serial port configuration error. DLE, XON, XOFF are not valid values for either SOM or EOM.

For help, see “End of Message (EOM)” or “Start of Message (SOM)” in Chapter 9.

Configuration was not updated. You are configuring the serial port and see this error message when exiting the Configuration Menu:

PG is the Handshake configuration command. You need to change the value of Handshake or set other serial port parameters. Choose Serial Port from the Communications Menu.

PG command failed.

The order in which you set serial port protocol configuration commands is important. To use Frame mode, you need to set EOM first. Next, configure Configuration Commands Via Serial Port, Handshake, LRC, and then SOM. To use Character mode, you need to disable these same parameters in reverse order.

Configuration was not updated.

For help, see “Using Serial Communications on the Terminal” in Chapter 4. You are configuring SOM or EOM in the Configuration Menu and cannot set two characters.

You may have a space in the SOM or EOM field. The space does not show, but it is a valid character. To clear a space from the field, put the . Now set the two-character value for cursor in the field and press SOM or EOM.

You are scanning a configuration command to set one of the serial port parameters and hear three low beeps. For example, you are trying to set EOM or SOM.

The order in which you scan serial port protocol configuration commands is important. The Configurable protocol uses EOM to determine the serial communications mode. When EOM is disabled, the terminal communicates in Character mode. When EOM is enabled, the terminal communicates in Frame mode.

d

To use Frame mode, you need to set EOM first. Next, configure Configuration Commands Via Serial Port, Handshake, LRC, and then SOM. To use Character mode, you need to disable these same parameters in reverse order. For help, see “Using Serial Communications on the Terminal” in Chapter 4.

6-9

Page 257

TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual Nugget Co de 39

Problems While Configuring the Terminal (continued) Problem

Solution

You see this error message when exiting the Configuration Menu:

The two-character name (syntax) of the configuration command that failed is listed on the first line of the error message. For example, you may see this message:

Commandname command failed. Remainder of configuration not updated.

SS command failed. There may be a problem with the configuration due to a change made with the Scanner Selection (SS) command. Check the command listed in the message. To find the command, use the “Configuration Commands by Syntax” table in Appendix A. Make sure the command is set correctly for the options and network communications you are using with the terminal. For help, see Chapter 9, “Configuration Command Reference.”

You scan a configuration command, such as Keypad Caps Lock, and you hear three low beeps.

If you are working in the TRAKKER Antares 2400 Menu System, you cannot scan configuration commands. Use the Configuration Menu to change the terminal’s configuration, or exit the menu system to scan configuration commands.

You scan a configuration command, such as Keypad Caps Lock, and nothing happens.

There are two possible solutions: • You may have one or more reader commands disabled, such as Change Configuration, so that you cannot change the configuration. Enable all of the reader commands and try again. • The terminal may be waiting for another command to complete the configuration change. If you started by scanning the Enter Accumulate command, you must finish the command by scanning the Exit Accumulate command. For help, see Chapter 9, “Configuration Command Reference.” Scan the Enable Override to temporarily enable all of the reader commands. When you are finished, remember to disable the override so that your data is not interpreted as a command. Enable Override

*$+DC3* *$+DC3*

6-10

Page 258

Nugget

Troubleshooting Co de 39

6

Problems While Configuring the Terminal (continued) Problem

Solution

You scan a configuration command to set one of these parameters and hear three low beeps:

If the Network Activate command is enabled (2.4 GHz RF network enabled) and you are configuring the terminal, these addresses must define a valid network configuration. For example, an invalid network configuration would be a controller (or host) IP address set to 0.0.0.0 with the network enabled.

• Controller IP Address (UDP Plus) or Host IP Address (TCP/IP) • Terminal IP Address • Default Router • Network Activate

To set these four parameters, follow these steps: 1. Disable the Network Activate (NA) configuration command. 2. Set the terminal IP address and the controller IP address or the host IP address. 3. Set the default router address (if necessary). 4. Enable the Network Activate command. You can change an IP address with the network enabled as long as it still defines a valid network configuration.

Terminal Will Not Communicate With RF Network Devices If you cannot get the terminal to communicate with other devices in the 2.4 GHz RF network, check these possible problems. Problem

Solution

When you turn on the terminal after it was suspended for awhile (10-15 minutes or longer), the terminal can no longer send or receive messages over the network.

The host may have deactivated or lost your current terminal emulation session. In a TCP/IP direct connect network, you need to turn off the “Keep Alive” message (if possible) from the host so that the TCP session is maintained while a terminal is suspended.

The Network Connect status light is turned off. The terminal is not communicating with the access point.

Make sure the Network Activate command is enabled. Also make sure the terminal is configured correctly for your network. To communicate with the access point, the RF domain and RF security ID on the terminal must match the values set for all access points the terminal may communicate with. For help, see “Using RF Communications on the Terminal” in Chapter 4. Make sure the access point is turned on and operating. You may be using the terminal out of the RF range of an access point. Try moving closer to an access point to re-establish communications. In a TCP/IP direct connect network, you cannot scan or enter data when the terminal is not communicating with an access point or you may lose your TCP session. Try moving closer to an access point to re-establish communications.

6-11

Page 259

TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual Nugget Co de 39

Terminal Will Not Communicate With RF Network Devices (continued) Problem

Solution

The Network Connect status light blinks.

In a UDP Plus network, the terminal is not connected to the DCS 300. You may need to check the terminal’s configuration or make sure the DCS 300 is running and that data collection is started. The terminal may be out of range of an access point or the access point may have recently been turned off. Make sure the access point is still turned on. Each device in the 2.4 GHz RF network must have a valid IP address. The IP addresses set on the terminal must match the addresses configured on the DCS 300 or host. For help, see “Using RF Communications on the Terminal” in Chapter 4.

The terminal is connected to the host computer and you move to a new site to collect data. The Network Connect status light was on and now begins to blink or turns off.

You may have gone out of range of an access point. Try moving closer to an access point or to a different location to re-establish communications. Once you are in range again, the Network Connect status light will appear and remain on. Any data you collected while you were out of range will be transmitted over the network.

The Network Connect status light blinks and you see this message:

The terminal is connected to the access point, but is trying to establish communications with the DCS 300 and the host computer. Make sure the terminal is correctly configured for your network. Make sure the DCS 300 is configured and running. Make sure the host computer is configured and running.

Unable to connect to controller. Error 102. Unable to establish connection to host. Session ended.

If you have configured the network correctly, try restarting the DCS 300 to establish communications. You can also try resetting the terminal. For help, see “Resetting the Terminal” later in this chapter.

The Network Connect status light remains on, but the host computer is not receiving any data from the terminal.

There may be a problem with the connection between the DCS 300 and the host computer. Check with your network administrator or use the DCS 300 System Manual to troubleshoot any potential problems on the controller. In a TCP/IP network, there may be a problem with the connection between the access point and the host computer. Check with your network administrator or use your access point user’s manual.

The Network Connect status light remains on, but you cannot establish a terminal emulation session with the host computer.

There may be a problem with the host computer, a problem with the connection between the DCS 300 and the host computer, or a problem with the connection between the access point and the host (TCP/IP). Check with your network administrator to make sure the host is running and allowing users to login to the system.

6-12

Page 260

Nugget

6

Troubleshooting Co de 39

Problems Transmitting Data Through the DCS 300 If you have a problem while running the application on the terminal in a UDP Plus network, check these possible communications problems. Problem

Solution

Transaction Buffer Full.

The buffer holding transactions to be sent to the controller is full. Stop collecting data with this terminal. Make sure the terminal is communicating with the DCS 300 and let the terminal send all the transactions in the buffer before you continue collecting data.

Sending Buffer Transactions.

This is an information message to tell you that buffered transactions are now being sent to the DCS 300. You can begin collecting data again once the message clears.

Transaction Aborted.

The transaction just sent to the DCS 300 was not received. Try sending the transaction again.

Transmit Error XX, press Enter.

There is an error transmitting data to the DCS 300. XX represents the status code error. Note the error code listed in the message and contact your local Intermec service representative for help. Press to continue.

Receive Error XX, press Enter.

There is an error receiving data from the DCS 300. XX represents the status code error. Note the error code listed in the message and contact your local Intermec service representative for help. Press to continue.

Shutting down.

The DCS 300 is shutting down. You may continue collecting data and buffer the transactions in the terminal until the DCS 300 starts again, or stop collecting data with the terminal.

Controller Shutdown.

The DCS 300 has shut down. You may continue collecting data and buffer the transactions in the terminal until the DCS 300 starts again, or stop collecting data with the terminal.

6-13

Page 261

TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual Nugget Co de 39

Bar Code Labels Will Not Scan If you cannot scan bar code labels or you are having problems with the laser scanner that is attached to the Scanner port, check these possible problems. Problem

Solution

A laser scanner is not attached to the Scanner port.

Make sure a laser scanner has been attached correctly to the Scanner port. For help, see “Attaching a Scanner” in Chapter 2.

The terminal is turned off.

Make sure the terminal is turned on. Press

You cannot see a red beam of light when you aim the scanner at a bar code label and pull the trigger.

There are two possible problems:

f to turn on the terminal.

• You may be too far away from the bar code label. Try moving closer to the bar code label and scan it again. • You may be scanning the bar code label “straight on.” Try changing the scanning angle until the laser beam is the brightest. This is the best scanning angle. You can test the effective range of the scanner. Move within 2 feet of a wall and test the scanner. You need to be within the scanning range to scan bar code labels. For help on scanning distances, see the guide that shipped with your laser scanner.

Warning Do not look directly into the window area or at a reflection of the laser beam while the laser is scanning. Long-term exposure to the laser beam can damage your vision. Avertissement Ne regardez pas directement la réflexion d’un rayon laser ou dans la fenêtre du laser lorsque celui-ci est en opération. Si vous regardez trop longtemps un rayon laser, cela peut endommager votre vue. You have a laser scanner attached to the Scanner port and cannot read any bar code labels.

You may not be using a laser scanner or cable that is supported for the T2455. For a list of supported scanners and cables, see “Input Devices for the Scanner Port” and “Cable Accessories” in Appendix A. Or, you may have the Scanner port configured for COM4. For help, see “Scanner Port (COM4)” in Chapter 9.

The laser scanner does not appear to work well or read bar code labels very quickly.

Try setting the Scanner Selection command to the specific input device you have attached. Check the bar code symbologies you have enabled on the terminal. Enable only the symbologies that you are using.

The laser scanner does not read the bar code labels quickly, or the scanning beam seems to be faint or obscured.

The scanner window may be dirty. Clean the scanning window with a solution of ammonia and water. Wipe dry. Do not allow abrasive material to touch the window.

6-14

Page 262

Nugget

Troubleshooting Co de 39

6

Bar Code Labels Will Not Scan (continued) Problem

Solution

The laser scanner will not read the bar code label.

Try these solutions: • Make sure you aim the scanner beam so it crosses the entire bar code label in one pass. • The angle you are scanning the bar code label may not be working well, or you may be scanning the label “straight on.” Try scanning the bar code label again, but vary the scanning angle. • The bar code label print quality may be poor or unreadable. To check the quality of the bar code label, try scanning a bar code label that you know scans. Compare the two bar code labels to see if the bar code quality is too low. You may need to replace the label that you cannot scan. • Make sure the bar code symbology you are scanning is enabled. Use the TRAKKER Antares 2400 Menu System to check the symbologies. On the Symbologies Menu, each symbology that is enabled has an asterisk (*) next to the name of the symbology. If your bar code symbology is disabled, enable it and then try scanning the bar code label again.

When you pull the trigger, the Good Read status light does not turn on.

Move within 2 feet of a wall and pull the trigger again. Make sure the scanner emits the red laser beam. If the status light does not turn on, there may be a problem with it. For help, contact your local Intermec service representative. If the laser beam does not turn on, check the other problems in this section for a possible solution.

When you release the trigger, the Good Read status light does not turn off.

The status light remains on if you configure the terminal to use edge triggering. If you configure the terminal for level triggering and the Good Read status light remains on, there may be a problem with the status light. Pull the trigger again without scanning a bar code label. If the status light is still on, contact your local Intermec service representative.

6-15

Page 263

TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual Nugget Co de 39

Protecting Delicate Electronic Components As Intermec moves to surface mount technology and smaller components, our products become more vulnerable to damage from electrostatic discharge (ESD). Recently Intermec experienced spare board assembly failures in the field that were traced to improper ESD protection while handling or installing the boards. This is costly and can be easily avoided. Intermec’s Service department recommends that all field personnel follow three guidelines to prevent ESD damage: •

Use an ESD mat and wrist strap when repairing and replacing printed circuit boards.

•

Before you open any Intermec product, place that product on an ESD mat and ground the product.

•

Follow all standard ESD procedures for your workplace.

This icon appears at the beginning of any procedure in this manual that could cause you to touch components (such as printed circuit boards) that are susceptible to damage from electrostatic discharge (ESD). When you see this icon, you must follow standard ESD guidelines to avoid damaging the equipment you are servicing. Follow ESD Procedures

The Everett facility uses several vendors for ESD products. One USA vendor is DESCO Industries, Inc., which you can reach at telephone (909) 598-2753 or on the World Wide Web at http://www.desco.com/. This table lists part numbers from DESCO’s 1996 catalog. However, you may want to find your own sources for ESD products.

6-16

Part Number

Description

7755

Large Service Kit 22 x 24

7780

Standard Service Kit 18 x 22

7790

Pocket Kit 15 x 20

A77115

Work Table Mat 24 x 48