The text of a manual · part 34 of 59
Trakker Antares 24XX Terminal User's Manual Addendum: Chapter 6 - Troubleshooting, pages 264 to 271
Pages 264 to 271 of 501, from Trakker Antares 24XX Terminal User's Manual Addendum
The original document is the PDF (2.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 2455
Page 264
Nugget
Troubleshooting Co de 39
6
Maintaining and Cleaning the Terminal The terminals are built for use in a rugged, industrial working environment. You may need to perform these minor maintenance tasks to keep the terminal in good working order: •
Clean the terminal screen.
•
Check the mounting bracket.
Each procedure is described in detail in this section. To order replacement parts, contact your local Intermec service representative or contact Intermec at: Intermec Corporation 6001 36th Ave. West P.O. Box 4280 Everett, Washington 98203-9280 Telephone: 1-425-348-2600
Cleaning the Terminal Screen To keep the terminal in good working order, you need to clean the terminal screen. Clean this surface as often as needed or when it is dirty. To clean the terminal screen 1. Press f to turn off the terminal.
2. Use a solution of ammonia and water. 3. Dip a clean towel or rag in the ammonia solution and wring out the excess solution. Wipe off the terminal screen. Do not allow any abrasive material to touch this surface. 4. Wipe dry.
Checking the Mounting Bracket Periodically inspect the knob on the mounting bracket to make sure they are still tight. Check the mounting bracket for any signs of fatigue, such as cracking, which might develop over extended use in extreme (vibration) environments. Replace any damaged hardware immediately to ensure continued, safe operation.
6-17
Page 265
TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual Nugget Co de 39
Booting the Terminal You seldom need to boot or reset the terminal. When you boot the terminal, it runs through power-on self test (POST) to test each major subsystem. The terminal uses the configuration currently saved in flash memory. Once the terminal is finished booting, your application appears on the screen. You can boot the terminal using these two methods:
f key to boot the terminal when you turn on the terminal.
•
Configure the
•
Use the Boot Menu.
Booting the Terminal on Resume f f
When you press to turn off the terminal, it turns off and goes into Suspend mode. When you press to turn on the terminal, it resumes or boots depending on the terminal configuration. There are two ways to configure the command:
f key using the Resume Execution configuration
Resume Execution Not Allowed Configures the terminal to boot and restart your application each time you press to turn on the terminal. Use this option if you want to restart your application every time you turn on the terminal.
f
Resume Execution Allowed Configures the terminal to resume exactly where it was when you turned off the terminal. Use this option to resume working each time you turn on the terminal. You can configure the Resume Execution command by using the TRAKKER Antares 2400 Menu System or by scanning these bar code labels. For help, see Chapter 3, “Configuring the Terminal,” or “Resume Execution” in Chapter 9. Resume Execution Not Allowed
Resume Execution Allowed
*$+ER0*
*$+ER1*
*$+ER0*
*$+ER1*
Using the Boot Menu The Boot menu appears after you:
6-18
• replace the backup battery and turn on the terminal.
• upgrade the firmware.
• reset the terminal.
Page 266
Nugget
Troubleshooting Co de 39
6
Boot Menu
BOOT
MENU
F1
-
Boot
F2
-
Run
F3
-
Power
POWER
DOWN
System Loader
IN
Down
60
SEC 2455U.040
The Boot Menu contains these commands:
b Run Loader Press Z to load the terminal firmware. To upgrade or load the firmware,
Boot System Press to boot the terminal. Once the terminal is finished booting, your application appears on the screen. you should use the Firmware Upgrade option in the TRAKKER Antares 2400 Menu System. For help, see “Upgrading the Firmware” in Chapter 3.
[
Power Down Press to turn off the terminal. When you turn on the terminal, the Boot Menu screen appears again if POST passes.
Troubleshooting a Locked Up Application If the terminal or application appears to be locked up, try these steps in order. To troubleshoot a locked-up terminal or application f
1. Press to turn off the terminal. If it turns off, press continue working.
f to turn on the terminal and
2. Scan the Reset Firmware label to restart the firmware and application. Reset Firmware
*-.* *-.*
You can also send the Reset Firmware command over the network. For help, see Chapter 8, “Reader Command Reference.” If it works, you can continue working.
6-19
Page 267
TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual Nugget Co de 39
3. Scan the Boot Terminal label to reboot the terminal. If it works, you can continue working. Boot Terminal
*-.1* *-.1* f
4. Configure the Resume Execution command to resume “not allowed.” For help, see “Resume Execution” in Chapter 9. Each time you press to turn on the terminal, the terminal boots and restarts your application.
a
5. If your terminal appears to boot but the application will not run or is locked up, press and hold the key immediately after you scan the Reset Firmware label or press to turn on the terminal in Step 3. Continue to hold the key for at least 30 seconds after the TRAKKER Antares welcome screen has cleared.
f a
The terminal has booted without loading an application. Use the TRAKKER Antares 2400 Menu System to load another application or download a new version of the application before you run it again. 6. If the terminal will not turn off or does not respond to the Reset Firmware command, reset the terminal as described in the next procedure. Make sure you have tried Steps 1 and 2 before you reset the terminal.
Resetting the Terminal If you performed the steps in “Troubleshooting a Locked Up Application” and the terminal will not turn off or respond to the Reset Firmware command, follow the steps in this section to reset the terminal. Perform this procedure only in a clean, dry area to avoid trapping any moisture or dirt inside the unit. Caution If the terminal is turned on and you push the Reset button, you may lose data and you may have to reload the firmware. Conseil Si le terminal est allumé et que vous appuyez sur le bouton de remise à zéro, vous risquez de perdre des données et d’avoir à recharger le microprogramme.
1. Use an ESD mat and wear a wrist strap to protect the components from ESD damage. For help, see “Protecting Delicate Electronic Components” earlier in this chapter. Follow ESD Procedures
6-20
2. Press f to turn off the terminal. If it will not turn off, continue with the next step.
3. Unplug the port plugs from any terminal ports that do not have a cable connected.
Page 268
Nugget
Troubleshooting Co de 39
6
4. Use a Torx screwdriver (size 20) to remove the four screws on the back panel. Screw (4 places)
2455U.098
5. Remove the back panel. 6. Press the Reset button. The T2455 will briefly turn on and then turn off. Reset button
2455U.099
7. Place the back panel on the back of the terminal. 8. Use a Torx screwdriver (size 20) to tighten the four screws to 24 in-lb torque. 9. Insert the rubber port plug into each terminal port that does not have a cable connected.
f
10. Press to turn on the terminal. It boots all the systems and clears RAM memory. The Boot Menu appears.
6-21
Page 269
TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual Nugget Co 11. Press de 39 b to boot the terminal and start your application.
If you keep returning to the Boot Menu or the terminal will not boot, try loading the firmware. For help, see “Upgrading the Firmware” in Chapter 3. If the terminal will not boot or reset, contact your local Intermec service representative for help.
Replacing the Backup Battery The backup battery should provide years of backup battery power and you will seldom need to replace it. You can replace the backup battery if it will no longer hold a charge, if the battery status on the Battery/PIC diagnostic screen is bad, or if the battery is dead. Call your local Intermec service representative to order a new backup battery (Part No. 066900S-001). Caution When you replace the backup battery, all data stored in RAM is lost. Conseil Lors du remplacement de la batterie de secours, toutes les données stockées dans la mémoire vive (RAM) sont perdues.
Removing the Backup Battery Perform this procedure only in a clean, dry area to avoid trapping any moisture or dirt inside the unit. 1. Use an ESD mat and wear a wrist strap to protect the components from ESD damage. For help, see “Protecting Delicate Electronic Components” earlier in this chapter. Follow ESD Procedures
2. Save all data stored in RAM and exit the application. Any data stored in flash memory or on drive G will be saved automatically. 3. Press f to turn off the terminal.
4. Disconnect the power cable. 5. Unplug the port plugs from any terminal ports that do not have a cable connected. 6. Use a Torx screwdriver (size 20) to remove the four screws on the back panel. 7. Remove the back panel. Notice that the foam pad on the inside of the panel was positioned over the backup battery. Later, when you replace the back panel, you must make sure the foam pad returns to that position.
6-22
Page 270
Nugget
Troubleshooting Co de 39
6
8. Disconnect the battery wire connector from the white connector marked J2 on the input/output (I/O) board. Backup battery
J2 connector
2455U.132
9. Lift the backup battery from its compartment. 10. Set the backup battery aside for disposal as described in “Disposing of the NiCad Backup Battery” later in this chapter. 11. Follow the steps in the next section to install the new backup battery.
Installing the New Backup Battery 1. Place the new backup battery into its compartment.
Follow ESD Procedures
2. Connect the battery wire connector to the white connector marked J2 on the I/O board. Firmly push the two connectors together until they lock. (The connectors are keyed so they cannot be connected incorrectly.) 3. Place the back panel on the back of the terminal. Make sure the foam pad is positioned over the backup battery. 4. Use a Torx screwdriver (size 20) to tighten the four screws to 18 to 24 in-lb torque. 5. Insert the rubber port plug into each terminal port that does not have a cable connected. 6. Reconnect the power supply cable.
f 8. Press b to boot the terminal and start your application. The backup battery will be 7. Press to turn on the terminal. It boots all the systems and clears RAM memory. The Boot Menu appears. fully charged in approximately 14 hours.
Note: The backup battery charges enough within 20 minutes to provide limited backup power.
6-23
Page 271
TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual Nugget Co de 39
Disposing of the NiCad Backup Battery The materials used in the construction of the TRAKKER Antares NiCad backup battery are recyclable. Intermec strongly urges that you recycle the backup batteries when they reach the end of their useful lives. Additionally, the Environmental Protection Agency has classified worn out or damaged NiCad batteries or battery packs to be hazardous waste. Several states have passed legislation that prohibits discarding these batteries into the municipal waste stream. If you have any question on how to recycle or dispose of the NiCad backup batteries, contact your local, county, or state hazardous waste management office.
6-24