Page 248

6 Troubleshooting

Page 249

6-2

Page 250

Nugget

Troubleshooting Co de 39

6

This chapter lists the problems you may have while using the terminal and gives some possible solutions. You will also find instructions that explain how boot or reset the terminal, clean the terminal screen, and replace the backup battery.

How to Use This Chapter If you have any problems with the TRAKKER Antares 2455 terminal, use this table as a guide to find the problem and solution in this chapter: Problem

See This Section to Find a Solution

Page

Screen is blank, terminal is locked up, or message is displayed.

“Problems While Operating the Terminal”

6-5

Configuring the terminal

“Problems While Configuring the Terminal”

6-7

RF communications error

“Terminal Will not Communicate With RF Network Devices”

6-11

Application error

“Problems Transmitting Data Through the DCS 300”

6-13

Scanning labels

“Bar Code Labels Will Not Scan”

6-14

Boot Menu appears or terminal is locked up.

“Booting the Terminal”

6-18

The terminal screen is dirty, or the mounting bracket bolts are loose.

“Maintaining and Cleaning the Terminal”

6-17

Note: If you have problems with the 3270, 5250, or VT/ANSI terminal emulation application, see the TRAKKER Antares Terminal Emulation User’s Guide.

6-3

Page 251

TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual Nugget Co de 39

Finding and Solving Problems If you have a problem while configuring or using the terminal, use the tables in this section to find a solution. For easy reference, problems are grouped into these topics: •

Problems While Operating the Terminal

•

Problems While Configuring the Terminal

•

Terminal Will Not Communicate With RF Network Devices

•

Problems Transmitting Data Through the DCS 300

•

Bar Code Labels Will Not Scan

•

Protecting Delicate Electronic Components

•

Maintaining and Cleaning the Terminal

•

Booting the Terminal

•

Troubleshooting a Locked Up Application

•

Resetting the Terminal

•

Replacing the Backup Battery

Note: You can also use the diagnostics to help analyze and solve problems. For help, see Chapter 7, “Running Diagnostics.” Caution There are no user-serviceable parts inside the terminal. Opening the unit will void the warranty and may cause damage to the internal components. Conseil La terminal ne contient pas de pièces révisibles par l’utilisateur. Le fait d’ouvrir l’unité annule la garantie et peut endommager les pièces internes. If you send the terminal in for service, it is your responsibility to save the terminal data and configuration. Intermec is responsible only for ensuring that the keypad and other hardware features match the original configuration when repairing or replacing your terminal.

6-4

Page 252

Nugget

Troubleshooting Co de 39

6

Problems While Operating the Terminal If you are operating the terminal and have trouble, check these possible problems and solutions. Problem

Solution

The screen is blank and the Power status light is blinking.

Make sure the external power supply is connected. The terminal cannot operate without an external power supply.

You scan a reader command, such as Backlight On, and nothing happens.

The reader commands are disabled. Scan the Enable Override command shown here to temporarily enable all of the reader commands. You can also enable or disable reader commands with the TRAKKER Antares 2400 Menu System. For help, see “Command Processing” in Chapter 9. When you are finished, remember to disable the override so that your data is not interpreted as a command. Enable Override

*$+DC3* *$+DC3* You scan a valid bar code label to enter data for your application. The data decoded by the scanner does not match the data encoded in the bar code label.

The terminal may have decoded the bar code label in a symbology other than the label’s actual symbology. Try scanning the bar code label again. Make sure you scan the entire label.

You want to set the terminal back to the default configuration to start over configuring the terminal.

Scan this bar code label:

To operate the terminal quickly and efficiently, you should enable only the bar code symbologies that you are going to scan. If you enable multiple symbologies, the terminal may on rare occasions decode a bar code according to the wrong symbology and produce erroneous results.

Default Configuration

*.+* *.+*

Or, use the TRAKKER Antares 2400 Menu System. For help, see “Restoring the Terminal’s Default Configuration” in Chapter 3. Note: After you load the default configuration on a T2455, you may need to set the primary network communications parameters to communicate with other devices in the network. You cannot scan bar code labels with the laser scanner attached to the Scanner port.

See “Bar Code Labels Will Not Scan” later in this chapter.

6-5

Page 253

TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual Nugget Co de 39

Problems While Operating the Terminal (continued) Problem

Solution

The terminal appears to be locked up and you cannot enter data.

Try these possible solutions: • Wait at least 10 seconds and try again. If the terminal is in the process of connecting to the DCS 300 or host, the terminal will ignore any input from the keypad or scanner. If the Network Connect status light appears and remains on, you can continue working. • Scan any bar code label to see if the terminal responds. • Follow the instructions in “Troubleshooting a Locked Up Application” later in this chapter.

The terminal is booting and you see a message that POST failed.

The screen displays the system that failed POST. Report the error message to your supervisor.

] to exit the error message. The Boot Menu appears. Press Press boot the terminal. Your application appears on the screen. If the terminal still will not boot, contact your local Intermec service representative for help. The terminal displays the Boot Menu.

You will see the Boot Menu in these two situations:

b to b

• You replace the backup battery. Once you replace the battery and turn on the terminal, the Boot Menu appears. Press to boot the terminal and continue working.

b

• You just finished upgrading the firmware on the terminal and POST failed. Press to boot the terminal. Report the problem to your supervisor. For help on the Boot Menu, see “Booting the Terminal” later in this chapter. The Power status light blinks and an external power supply is connected.

The backup battery charge is low. Make sure an external power supply is connected and there is power to the terminal. The backup battery will be fully charged in approximately 14 hours. If you have been using the terminal in a cold temperature environment, move the terminal to a warmer environment to charge the backup battery. You can replace the backup battery if it will no longer hold a charge, if the battery status on the Battery/PIC diagnostic screen is bad, or if the battery is dead. For help, see “Replacing the Backup Battery” later in this chapter.

6-6

Page 254

Nugget

Troubleshooting Co de 39

6

Problems While Configuring the Terminal You can configure the terminal by using the TRAKKER Antares 2400 Menu System or by scanning configuration commands. If you have problems configuring the terminal, check these possible problems and solutions. Problem

Solution

On the T2455, you configure the RF security ID and the changes do not appear to be saved.

You can only set the RF security ID with the 2.4 GHz RF network enabled. The Network Activate configuration command must be configured to 2.4 GHz RF network before you can save any changes to the RF security ID command.

You see this error message when exiting the Configuration Menu:

The 2.4 GHz RF network is enabled and there is a problem with the network configuration. You need to change the terminal IP address and/or the controller IP address (host IP address for a TCP/IP network). Choose Primary Network from the Communications Menu.

Network configuration error. Network is enabled. Terminal IP address or Controller (Host) IP address set to an invalid address of 0.x.x.x or 127.x.x.x. Configuration was not updated.

You see this error message when exiting the Configuration Menu: Network configuration error. Network is enabled. Terminal IP address and Default Router address set to the same address. Configuration was not updated.

The terminal IP address or the controller/host IP address is set to 0.x.x.x or 127.x.x.x. These are invalid addresses. Set a valid IP address for the terminal and DCS 300 or host. For help, see “Using RF Communications on the Terminal” in Chapter 4. If you cannot fix the addressing problem, check with your network administrator to get the IP address assigned to the terminal and the controller or host. The 2.4 GHz RF network is enabled and there is a problem with the network configuration. You need to change the terminal IP address and/or the default router address. Choose Primary Network or Advanced Network from the Communications Menu. The terminal IP address and the default router address are both set to the same address. Set a valid IP address for the terminal and the default router. For help, see “Using RF Communications on the Terminal” in Chapter 4. If you cannot fix the addressing problem, check with your network administrator to get the IP addresses for each RF network device.

You see this error message when exiting the Configuration Menu: Network configuration error. Network is enabled. Terminal IP address or Controller (Host) IP address set to the same address. Configuration was not updated.

The 2.4 GHz RF network is enabled and there is a problem with the network configuration. You need to change the terminal IP address and/or the controller IP address (host IP address for a TCP/IP network). Choose Primary Network from the Communications Menu. The terminal IP address and the controller/host IP address are both set to the same address. Set a valid IP address for the terminal and DCS 300 or host. For help, see “Using RF Communications on the Terminal” in Chapter 4. If you cannot fix the addressing problem, check with your network administrator to get the IP address assigned to the terminal and the controller or host.

6-7

Page 255

TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual Nugget Co de 39

Problems While Configuring the Terminal (continued) Problem

Solution

You see this error message when exiting the Configuration Menu:

The 2.4 GHz RF network is enabled and there is a problem with the network configuration. You need to change the default router address. Choose Advanced Network from the Communications Menu.

Network configuration error. Network is enabled. Default Router address is not on the terminal’s network. Configuration was not updated.

The terminal and DCS 300 (UDP Plus network) or host (TCP/IP network) are on different networks, and the terminal is not on the same network as the default router. When the terminal is on a different IP subnetwork from the DCS 300 or host, you must set the Default Router and Subnet Mask commands. Set a valid IP address for terminal, DCS 300 or host, and default router. For help, see “Using RF Communications on the Terminal” in Chapter 4. If you cannot fix the addressing problem, check with your network administrator to get the IP addresses for each RF network device.

You are configuring the serial port and see this error message when exiting the Configuration Menu:

You must configure a value for EOM before you can set SOM or disable SOM. You need to change the value of SOM. Choose Serial Port from the Communications Menu.

Serial port configuration error.

The Configurable protocol uses EOM to determine the serial communications mode. When EOM is disabled, the terminal communicates in Character mode. When EOM is enabled, the terminal communicates in Frame mode. To use Frame mode, you need to set EOM first. Next, configure Handshake, Configuration Commands Via Serial Port, LRC, SOM, and then Poll.

SOM is set. You must also set EOM. Configuration was not updated.

For help, see “Using Serial Communications on the Terminal” in Chapter 4. You are configuring the serial port and see this error message when exiting the Configuration Menu: Serial port configuration error.

SOM cannot equal the same value that is set for EOM. You cannot set SOM to any of these values: AFF (ACK), DLE, NEG (NAK), Poll, RES (EOT), REQ (ENQ), SEL, XOFF, or XON. You need to change the value of SOM. Choose Serial Port from the Communications Menu. For help, see “Start of Message (SOM)” in Chapter 9.

SOM cannot equal EOM. Configuration was not updated. You are configuring the serial port and see this error message when exiting the Configuration Menu: Serial port configuration error. EOM #1 cannot equal EOM #2. Configuration was not updated.

6-8

EOM can be one or two ASCII characters, but you cannot set the first and second character to the same character. Also, you cannot set EOM to any of these values: AFF (ACK), DLE, NEG (NAK), Poll, RES (EOT), REQ (ENQ), SEL, XOFF, or XON. You need to change the value of EOM #1 or #2. Choose Serial Port from the Communications Menu. For help, see “End of Message (EOM)” in Chapter 9.